This study aims to test the effectiveness of a novel combined endotracheal tube holder and bite guard when compared with the current standard of care, tape and an oral airway. Specifically, this new device will be tested among 1) neurosurgical patients lying face upward, 2) thoracic surgery patients lying on their side, and 3) orthopedic and neurosurgical spine surgery patients lying face downward.


Clinical Trial Description

Endotracheal tubes (ETT) are secured during surgery and ICU care so that they are not accidentally removed from the airway. The position of the tip of the ETT is important and must not vary much within the trachea. The standard technique for securing an ETT is to use tape to attach it to the upper lip and face. The technique is cheap and simple, but suffers from certain drawbacks. First, the upper lip is mobile and thus even when well secured, the tube can move within the trachea due to this mobility. Second, conditions on the face such as sweating, drooling, facial hair, skin flaking or breakdown, all interfere with the ability of the tape to adhere, thus reducing its efficacy. Furthermore, the tape itself can irritate and or injure the facial skin. The adhesive irritates skin and certain patients are allergic to these substances. Also, removing the tape can physically damage the skin, especially if the skin is vulnerable to sheer forces (such as elderly patients or patients on systemic steroids).

Patients that are intubated often need a bite block or bite guard inserted into their mouths. This serves two main purposes: 1) to prevent the patient from biting the ETT and occluding airflow, 2) to prevent the patient from biting their tongue, cheek, or lips causing injury. Furthermore, endoscopic procedures are often performed on intubated patients and thus a bite block is needed to protect the delicate instrument from being bitten and damaged. For these reasons, many providers will insert bite blocks into the mouths of intubated patients. Many such devices exist on the market, but the most commonly used is the Guedel oral airway. This device is actually designed to increase airway patency during mask ventilation, and long term use of this device as a bite block has been linked to numerous complications including: 1)tongue swelling, often compromising the airway patency, 2) tooth damage, and 3)lip injury. Because of these shortcomings, specific ETT bite blocks have been developed, and some of these even double as an ETT securing device. However, these are usually made of hard, stiff materials that in and of themselves can injure the delicate oral structures. In summation, no single device that both serves as an ergonomic ETT holder and bite block has been successfully developed and marketed, and therefore the standard of care remains tape plus an oral airway.

The Haider airway is a combination ETT holder-securing device and bite block. Made of soft silicone rubber, the device was engineered from the ground up to serve those purposes with safety and comfort in mind. The device is FDA approved and in a pre-marketing trials phase to determine the efficacy of the product in specific clinical scenarios. Our institution has been tasked with testing the device in three clinical scenarios where tape + oral airway has been historically problematic. We plan to compare this new device to tape + oral airway, the current standard of care, in 1) neurosurgical patients in the supine position, 2) thoracic surgery patients in the lateral position, and 3) surgery patients in the prone position. We hypothesize the device will be superior to the standard of care in both efficacy and patient comfort. ;


Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT02347488
Study type Interventional
Source University of California, Los Angeles
Contact
Status Completed
Phase Phase 4
Start date February 2015
Completion date January 2016

See also
  Status Clinical Trial Phase
Recruiting NCT05583916 - Same Day Discharge for Video-Assisted Thoracoscopic Surgery (VATS) Lung Surgery N/A
Completed NCT04448041 - CRANE Feasibility Study: Nutritional Intervention for Patients Undergoing Cancer Surgery in Low- and Middle-Income Countries
Completed NCT03213314 - HepaT1ca: Quantifying Liver Health in Surgical Candidates for Liver Malignancies N/A
Enrolling by invitation NCT05534490 - Surgery and Functionality in Older Adults N/A
Recruiting NCT04792983 - Cognition and the Immunology of Postoperative Outcomes
Terminated NCT04612491 - Pre-operative Consultation on Patient Anxiety and First-time Mohs Micrographic Surgery
Recruiting NCT06397287 - PROM Project Urology
Recruiting NCT04444544 - Quality of Life and High-Risk Abdominal Cancer Surgery
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03432429 - Real Time Tissue Characterisation Using Mass Spectrometry REI-EXCISE iKnife Study
Completed NCT04176822 - Designing Animated Movie for Preoperative Period N/A
Recruiting NCT05370404 - Prescribing vs. Recommending Over-The-Counter (PROTECT) Analgesics for Patients With Postoperative Pain: N/A
Not yet recruiting NCT05467319 - Ferric Derisomaltose/Iron Isomaltoside and Outcomes in the Recovery of Gynecologic Oncology ERAS Phase 3
Recruiting NCT04602429 - Children's Acute Surgical Abdomen Programme
Completed NCT03124901 - Accuracy of Noninvasive Pulse Oximeter Measurement of Hemoglobin for Rainbow DCI Sensor N/A
Completed NCT04595695 - The Effect of Clear Masks in Improving Patient Relationships N/A
Recruiting NCT06103136 - Maestro 1.0 Post-Market Registry
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Completed NCT04059328 - Novel Surgical Checklists for Gynecologic Laparoscopy in Haiti
Recruiting NCT03697278 - Monitoring Postoperative Patient-controlled Analgesia (PCA) N/A