Whether patient-maintained sedation (the patient controls his/her degree of sedation using a hand-held device) using the drug propofol is safer and more effective when using deteriorating reaction time as an added safeguard against the potential for over sedation in a groups of patients undergoing oral surgery, general dentistry and colonoscopy.


Clinical Trial Description

Patients receiving conscious sedation for dentistry and endoscopy are usually treated with intermittent bolus doses of intravenous midazolam (administered by the operator-sedationist). The safety of such a regime has been questioned with reports of up to 13 % of patients desaturating to below 80 % in the recovery area following sedation for endoscopy. Mortality occurs in 0.05 % of endoscopy patients (with approximately 60 % of this being due to hypoxaemia). The aim of our work, therefore, is to look at providing sedation that is both safer as well as being efficacious.

The drug propofol, the agent most commonly used to induce general anaesthesia in the UK, is also frequently administered intravenously by anaesthetists in low doses to provide conscious sedation for patients undergoing unpleasant procedures i.e. patients become relaxed, anxiety-free, but maintain verbal contact throughout.

The technique of patient maintained sedation using the drug propofol (the patient can increase the amount of sedation (and propofol) they receive by pressing a demand button attached to a standard infusion device) has been used by anaesthetists and evaluated since 1997.

Several recent studies published and submitted for publication by this research group on patient maintained sedation using the drug propofol have shown this method of sedation to be safe and effective in dental patients (over 120 patients studied). It was also shown that this method, when compared to the established method of sedation in oral surgery (the dentist administering doses of midazolam intravenously), to produce both quicker recovery and less anxiety prior to the surgery.

The routine use of propofol traditionally is restricted to anaesthetists, as in high doses general anaesthesia is produced with possible loss of airway patency. Currently the safety feature is predominantly that as patients become more sedated they cannot press the patient demand button and hence cannot increase the amount of propofol they are receiving. Also the device ensures that the blood and brain concentrations have equilibrated to within 10% of each other before another successful demand for propofol can be made (usually takes approximately two minutes) and it only allows a maximum calculated brain concentration of 3 micrograms/milliliter of propofol. The device also will start to decrease the calculated brain concentration of propofol if the demand button has not been pressed for six minutes.

Despite the encouraging results above we also found in a recent pilot study involving 20 healthy volunteers who were instructed to try and make themselves unconscious that there were 2 cases of over sedation (of these one briefly lost verbal contact and the other required supplemental oxygen only). Over sedation, however, was not demonstrated with any of the oral surgery patients in the previous studies. This may have been due to a higher level of anxiety in dental patients affecting response to propofol.

We have therefore incorporated an additional safety feature into the existing and previously studied patient maintained sedation system which may further decrease or eliminate this small risk of over sedation. All the above safety features are retained and in addition the patient demand button will now also be used to monitor reaction time at one minutely intervals.

It is known that propofol slows the reaction time of a given individual and in another recent study of 40 patients undergoing general anaesthesia for planned surgery using propofol, the patients’ reaction times were recorded both awake and during induction of anaesthesia by instructing the patients to press a button as quickly as possible in response to the handset vibrating. The calculated effect site (brain) concentration of propofol was increased incrementally and reaction time monitored at each stage until the patient could no longer press the button.

The data from this study (deteriorating patient reaction time with increased brain concentration of propofol) was analysed and this information used to provide an additional safety feature within the system to prevent over sedation i.e. a patient’s reaction time deterioration by a certain percentage will prevent himself or herself being able to self-administer more propofol. Furthermore the system will actually start to decrease the brain concentration of propofol once the patients’ reaction time becomes too slow. The patient demand button will be used to monitor reaction time at one minutely intervals as well as administer more propofol.

We hope that this will eliminate the small risk of over sedation and wish to conduct pilot studies to assess the safety and efficacy of this reaction time safeguarded, patient-maintained sedation system in three groups of twenty patients requiring sedation for planned procedures.

We have chosen two groups of dental patients, one group having oral surgery (technically more difficult dental work e.g. wisdom tooth removal) and one group having routine dentistry (e.g. patients having tooth fillings who are referred for sedation due to high anxiety levels). Another of our outcome measures will look at the effect of this technique on the patients’ anxiety levels and we believe that this technique may be beneficial in reducing anxiety levels.

Patient maintained sedation has also been studied in 20 colonoscopy patients and found to be efficacious. However there were also 4 cases of slight over sedation, none of whom required any intervention e.g. airway or circulatory. We hope that by incorporating the reaction time safeguard that we can again eliminate this small risk. ;


Study Design

Allocation: Non-Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00355693
Study type Interventional
Source University of Glasgow
Contact Sonia Allam, MB ChB FRCA
Phone 0141 211 4625
Email soniaallam@yahoo.com
Status Not yet recruiting
Phase Phase 4
Start date October 2006
Completion date February 2007

See also
  Status Clinical Trial Phase
Recruiting NCT05583916 - Same Day Discharge for Video-Assisted Thoracoscopic Surgery (VATS) Lung Surgery N/A
Completed NCT04448041 - CRANE Feasibility Study: Nutritional Intervention for Patients Undergoing Cancer Surgery in Low- and Middle-Income Countries
Completed NCT03213314 - HepaT1ca: Quantifying Liver Health in Surgical Candidates for Liver Malignancies N/A
Enrolling by invitation NCT05534490 - Surgery and Functionality in Older Adults N/A
Recruiting NCT04792983 - Cognition and the Immunology of Postoperative Outcomes
Terminated NCT04612491 - Pre-operative Consultation on Patient Anxiety and First-time Mohs Micrographic Surgery
Recruiting NCT06397287 - PROM Project Urology
Recruiting NCT04444544 - Quality of Life and High-Risk Abdominal Cancer Surgery
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03432429 - Real Time Tissue Characterisation Using Mass Spectrometry REI-EXCISE iKnife Study
Completed NCT04176822 - Designing Animated Movie for Preoperative Period N/A
Recruiting NCT05370404 - Prescribing vs. Recommending Over-The-Counter (PROTECT) Analgesics for Patients With Postoperative Pain: N/A
Not yet recruiting NCT05467319 - Ferric Derisomaltose/Iron Isomaltoside and Outcomes in the Recovery of Gynecologic Oncology ERAS Phase 3
Recruiting NCT04602429 - Children's Acute Surgical Abdomen Programme
Completed NCT03124901 - Accuracy of Noninvasive Pulse Oximeter Measurement of Hemoglobin for Rainbow DCI Sensor N/A
Completed NCT04595695 - The Effect of Clear Masks in Improving Patient Relationships N/A
Recruiting NCT06103136 - Maestro 1.0 Post-Market Registry
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Completed NCT04059328 - Novel Surgical Checklists for Gynecologic Laparoscopy in Haiti
Recruiting NCT03697278 - Monitoring Postoperative Patient-controlled Analgesia (PCA) N/A