Surgery Clinical Trial
Official title:
A Comparison of the Detection of Hypoventilation During Deep Sedation Utilizing Nasal End Title CO@ Versus Transcutaneous CO2 Measurement Techniques
The estimation of the partial pressure of carbon dioxide (PCO2) in the arterial blood is
used to judge the adequacy of ventilation during spontaneous and controlled ventilation.
Although the gold standard for monitoring PCO2 remains arterial blood gas sampling, this
requires an invasive procedure and provides only an intermittent estimate of what is
frequently a continuously changing value. The solution to this problem has been the
development and validation of accurate noninvasive monitoring techniques which provide a
continuous intraoperative estimate of PCO2.The most commonly used noninvasive technique to
monitor PCO2 is measurement of the end tidal CO2 (PECO2) . However, sampling errors and
patient -related issues such as ventilation-perfusion mismatch, patient positioning or
decreases in pulmonary blood flow may influence the accuracy of PECO2 monitoring (1-3).
Nasal capnography has been proved to be an accurate monitor during the post-operative period
(4) but its ability to accurately detect hypoventilation associated with deep sedation has
not been studied.
According to the American Society of Anesthesiologist standards for basic monitoring,
continuous capnography is required for all patients undergoing general anesthesia but it is
optional for MAC/sedation cases. The need for CO2 monitoring has been studied by other
medical specialties that use procedural sedation, including gastroenterology (12) and
emergency medicine (13, 14) and many specialties now recommend capnography as a standard
monitor.
Patients receiving supplemental oxygen may experience significant persistent hypoventilation
leading to progressive hypercarbia and acidosis which may go undetected for a significant
time interval since the routinely monitored SpO2 may be maintained within normal range. A
recent study has shown that despite the fact that end tidal CO2 is reliable in detecting
apnea , increasing oxygen flow rates decrease the amplitude of measured CO2, probably via
dilution, making the quantitative value less reliable as an assessment of adequacy of
ventilation (15). Furthermore, during hypoventilation there is reduced alveolar ventilation
and the end tidal CO2 is not a true reflection of arterial CO2.
Transcutaneous measurement of PCO2(PtcCO2) is a non-invasive method of measuring PCO2 that
has been used much less frequently due to technical difficulties with earlier transcutaneous
electrodes. Preliminary studies of the reliability of the current PtcCO2 electrodes (TOSCA,
Linde Medical Sensors, and Basel, Switzerland) have shown good correlation of arterial and
transcutaneous measurements in both adult volunteers and anesthetized subjects (5). PtcCO2
is measured with a sensor attached by a low pressure clip to an earlobe. The sensor probe
heats the earlobe to 42 degrees Celsius to enhance blood flow. The current sensors have also
been evaluated in anesthetized children (7, 8), anesthetized adults (9, 10) and critically
ill neonates (11) and all these studies revealed a good correlation between PtCO2 and PaCO2.
A group of _40 patients scheduled to undergo Hysteroscopy surgery with deep sedation will be
studied. Standard monitors will be utilized. Additionally a transcutaneous CO2 electrode
will be attached to the ear lobe and a BIS monitor will be applied to the forehead.
The anesthetic management will be left to the discretion of the anesthesia provider
(Anesthesia resident or CRNA, under the supervision of a faculty attending
anesthesiologist).All patients will receive supplemental oxygen at 3L/ minute via nasal
cannula, to maintain oxygen saturation greater than 90%.
Both the end tidal CO2 (ETCO2) and transcutaneous CO2 (TcCO2) (Linde Medical Sensors, Basel
, Switzerland ) will be calibrated before use, according to the manufacturer's instruction..
The anesthesia provider will be blinded to the TcCO2 monitor but will have access to the
ETCO2 values. The ETCO2 and TcCO2 values will be recorded simultaneously by an independent
observer.
One arterial blood samples will be collected from each subject for measurement of PaCO2 at a
deep level of sedation defined by a modified Ramsey score greater or equal to 5 (1=
anxious/agitated/restless; 2= cooperative/oriented/tranquil; 3= drowsy/responds to commands
only; 4= brisk response to shaking/loud sound; 5= sluggish response to shaking/loud sound;
6= no response) The ETCO2 and .TcCO2 will be recorded throughout the time of obtaining the
blood sample every 15 seconds and the mean value will be used for comparison.
Hypoventilation will be defined as a PaCO2 level greater than 45mmHg.
Sedation score (OASS) will be recorded on admission to recovery area. Time to meet discharge
criteria will be recorded.
The experimental procedures: ABG draw, ETCO2 monitor placement on the ear, 2 Ramey scale
assessments.
;
Allocation: Non-Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05583916 -
Same Day Discharge for Video-Assisted Thoracoscopic Surgery (VATS) Lung Surgery
|
N/A | |
Completed |
NCT04448041 -
CRANE Feasibility Study: Nutritional Intervention for Patients Undergoing Cancer Surgery in Low- and Middle-Income Countries
|
||
Completed |
NCT03213314 -
HepaT1ca: Quantifying Liver Health in Surgical Candidates for Liver Malignancies
|
N/A | |
Enrolling by invitation |
NCT05534490 -
Surgery and Functionality in Older Adults
|
N/A | |
Recruiting |
NCT04792983 -
Cognition and the Immunology of Postoperative Outcomes
|
||
Terminated |
NCT04612491 -
Pre-operative Consultation on Patient Anxiety and First-time Mohs Micrographic Surgery
|
||
Recruiting |
NCT06397287 -
PROM Project Urology
|
||
Recruiting |
NCT04444544 -
Quality of Life and High-Risk Abdominal Cancer Surgery
|
||
Completed |
NCT04204785 -
Noise in the OR at Induction: Patient and Anesthesiologists Perceptions
|
N/A | |
Completed |
NCT03432429 -
Real Time Tissue Characterisation Using Mass Spectrometry REI-EXCISE iKnife Study
|
||
Completed |
NCT04176822 -
Designing Animated Movie for Preoperative Period
|
N/A | |
Recruiting |
NCT05370404 -
Prescribing vs. Recommending Over-The-Counter (PROTECT) Analgesics for Patients With Postoperative Pain:
|
N/A | |
Not yet recruiting |
NCT05467319 -
Ferric Derisomaltose/Iron Isomaltoside and Outcomes in the Recovery of Gynecologic Oncology ERAS
|
Phase 3 | |
Recruiting |
NCT04602429 -
Children's Acute Surgical Abdomen Programme
|
||
Completed |
NCT03124901 -
Accuracy of Noninvasive Pulse Oximeter Measurement of Hemoglobin for Rainbow DCI Sensor
|
N/A | |
Completed |
NCT04595695 -
The Effect of Clear Masks in Improving Patient Relationships
|
N/A | |
Recruiting |
NCT06103136 -
Maestro 1.0 Post-Market Registry
|
||
Completed |
NCT05346588 -
THRIVE Feasibility Trial
|
Phase 3 | |
Completed |
NCT04059328 -
Novel Surgical Checklists for Gynecologic Laparoscopy in Haiti
|
||
Recruiting |
NCT03697278 -
Monitoring Postoperative Patient-controlled Analgesia (PCA)
|
N/A |