Clinical Trials Logo

Clinical Trial Summary

The purpose of this research study is to develop a protocol using a fully wearable, portable lower-limb exoskeleton for improving leg and walking function in people with movement disorders. The study investigates the effects of wearing the device during a set of experiments including leg stretching, treadmill walking and overground walking in muscle activity, joint motion, and gait performance. The goal is to develop an effective lower-limb strategy to restore lost leg function (e.g., range of motion) and gait ability, and improve quality of life in people with movement deficits following a neurological disorder.


Clinical Trial Description

People with neurological conditions, including individuals with upper motor neuron injury, experience motor and sensory deficits, muscle weakness, limited range of motion, low weight-bearing capacity, and impaired balance that limit ambulation and interfere with the ability to perform activities of daily living. Lower-limb rehabilitation robots can assist with physical therapy and alleviate the burden of caregivers and nurses. Thus, the goal of this project is to develop wearable and portable technology to assist leg motion and stretching, and correspondingly activate muscles in people with neurological conditions who experience spasticity. Spasticity results from increased muscle tone and interferes with the ability to functionally use voluntary muscle contraction for limb coordination and range of motion, which limits body transfers, ambulation, and exercise. Severe or intractable spasticity can lead to loss of body control and balance, resulting in falls and injuries, pressure injury of the skin, contractures, pain, wheelchair seating difficulties, in addition to other problems. Existent treatments to manage spasticity and overcome functional deficits related to spasticity include medications, neurosurgery, whole body or limb vibration, physical therapy, passive cycling, functional electrical stimulation (FES), along with other methods. However, medications may induce significant side effects including drowsiness, malaise, muscle weakness and pain (e.g., at the injection site); in addition, their effectiveness is sensitive to dosing fluctuations. Neurosurgery and direct spinal cord stimulation can treat intractable or focal spasticity, but they carry surgical risks, and their long-term benefits vary across individuals. Stretching can decrease the excitability of motor neurons, maintain the viscoelastic properties of muscles and joints, provide relief from muscles spasms, and improve range of motion and gait function; further, stretching can be combined with oral medications to manage spasticity. Stretching is performed routinely by therapists, nurses, and caregivers to provide muscle stretching or preserve range of motion in joints with relatively low adverse effects. However, providing on-demand, reliable, manual limb stretching throughout the day and night imposes a heavy burden on caregivers and nurses both at home and in medical facilities. Hence, a critical need exists to develop a wearable approach to applying on-demand, safe, and customized dynamic stretching to manage spasticity after SCI, which can minimize the burden of caregivers and nurses. This project exploits the recent technological advances in wearable sensors and fully wearable exoskeletons with reduced form factor and weight, which we have not exploited (nor developed) in our previous research protocols at Syracuse University. These novel wearable exoskeletons are smart garments that conform to the human body and provide leg assistance in people with muscle weakness or hemiplegia. Light-weight exoskeletons have the potential to expand the breadth of tasks and environments in which exoskeletons are used for. Hence, this project introduces a lightweight, wearable exoskeleton to assist leg motion and stretching (e.g., targeting people with spasticity) under different postures (e.g., while lying down on a mat or bed, sitting on a chair or in a wheelchair). Aim 1 characterizes the performance of the wearable device and its closed-loop control algorithm to apply precise adjustments for safe, automatic limb stretching and motion of single joints (e.g., joints in isolation while sitting or lying on a mat). The methods in this aim include the following: 1) design a control algorithm to apply safe leg forces exploiting joint kinematics and inertial feedback data using wearable sensors and 2) examine the magnitude and timing of the applied forces to the hip, knee and ankle joints, and toes. The research tasks in this aim will enable the customization of the applied forces across participants. Aim 2 expands the implementation of the closed-loop controller from Aim 1 to different body postures and activities that involve multi-joint control. Participants wear the device to experience the applied forces by the wearable exoskeleton while lying down on a bed/mat or sitting down. Since the device is fully wearable, it serves as a powerful tool to examine the motion and limb-stretching of individuals with neurological conditions and spasticity. Thus, the device is not limited to fixed/stationary experimental conditions. The last aim collects qualitative data from participants, caregivers, nurses, and clinicians (if involved) about the ease of use and satisfaction from using the wearable device. Questionnaires and surveys are used to gather qualitative data. Ease of use of the wearable device is assessed by examining if the protocol can be implemented within the expected duration including the time to don and doff the exoskeleton; further, it will be determined if the adherence to the protocol is achieved for all participants. Research Design- Methodology A candidate for the study will be asked to complete a Screening Questionnaire by phone or in person to check for eligibility. If the potential participant is eligible to enroll in the study, the participant will receive more information regarding the enrollment process. Participant will then complete a Demographics Questionnaire and answer questions about personal health and physical functioning. Each lab visit may take up to 2 hours (including fitting the device, warm-up, testing procedures, rest breaks, unfitting the device, and removing the electrodes and wearable sensors). Raw data will be collected from wearable sensors including the following: joint angles, 3D leg motion, muscle electromyography (EMG), and motor currents from the wearable device. Digital data recorded from experiments will be stored in .mat files (or .csv), password protected. There are no biological specimens collected. Metadata will be applied to each component of the dataset following acquisition to ensure data is prepared for proper archiving. Metadata will include type, format, date, time, storage location, and context of data. Data generated during this project use conventional digital formats including: - MS Word, Power Point, Excel, Portable Data Format (PDF), and LaTeX (tex) files - Graphics, figures, tables, animations, videos from tests (jpeg, png, eps, mp4 files) - Code including MATLAB/Simulink files, C++ code, and ASCII text files The paper participation records will be kept in locked file cabinets in the laboratory and/or offices, and the digital data will be stored on password-protected computers/servers or encrypted electronic storage devices in the offices and laboratory of the PIs' research team. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05926596
Study type Interventional
Source VA Office of Research and Development
Contact Steven W Brose
Phone (315) 425-4400
Email steven.brose@va.gov
Status Not yet recruiting
Phase N/A
Start date October 1, 2023
Completion date September 30, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT02574572 - Autologous Mesenchymal Stem Cells Transplantation in Cervical Chronic and Complete Spinal Cord Injury Phase 1
Recruiting NCT05941819 - ARC Therapy to Restore Hemodynamic Stability and Trunk Control in People With Spinal Cord Injury N/A
Completed NCT05265377 - Safety and Usability of the STELO Exoskeleton in People With Acquired Brain Injury and Spinal Cord Injury N/A
Recruiting NCT02331979 - Improving Bladder Function in SCI by Neuromodulation N/A
Completed NCT02777281 - Safe and Effective Shoulder Exercise Training in Manual Wheelchair Users With SCI N/A
Recruiting NCT02978638 - Electrical Stimulation for Continence After Spinal Cord Injury N/A
Completed NCT02262234 - Education Interventions for Self-Management of Pain Post-SCI: A Pilot Study Phase 1/Phase 2
Withdrawn NCT02237547 - Safety and Feasibility Study of Cell Therapy in Treatment of Spinal Cord Injury Phase 1/Phase 2
Completed NCT02161913 - Comparison of Two Psycho-educational Family Group Interventions for Persons With SCI and Their Caregivers N/A
Completed NCT01642901 - Zoledronic Acid in Acute Spinal Cord Injury Phase 3
Completed NCT01884662 - Virtual Walking for Neuropathic Pain in Spinal Cord Injury N/A
Terminated NCT02080039 - Electrical Stimulation of Denervated Muscles After Spinal Cord Injury N/A
Terminated NCT01433159 - Comparison of HP011-101 to Standard Care for Stage I-II Pressure Ulcers in Subjects With Spinal Cord Injury Phase 2
Completed NCT01471613 - Lithium, Cord Blood Cells and the Combination in the Treatment of Acute & Sub-acute Spinal Cord Injury Phase 1/Phase 2
Completed NCT01467817 - Obesity/Overweight in Persons With Early and Chronic Spinal Cord Injury (SCI) N/A
Completed NCT02149511 - Longitudinal Morphometric Changes Following SCI
Terminated NCT01005615 - Patterned Functional Electrical Stimulation (FES) Ergometry of Arm and Shoulder in Individuals With Spinal Cord Injury Phase 1/Phase 2
Completed NCT01086930 - Early Intensive Hand Rehabilitation After Spinal Cord Injury Phase 3
Completed NCT00663663 - Telephone Intervention for Pain Study (TIPS) N/A
Completed NCT01025609 - Dietary Patterns and Cardiovascular (CVD) Risk in Spinal Cord Injury (SCI) Factors In Individuals With Chronic Spinal Cord Injury