Clinical Trials Logo

Clinical Trial Details — Status: Withdrawn

Administrative data

NCT number NCT03043703
Other study ID # ES-RDIVal-01
Secondary ID
Status Withdrawn
Phase N/A
First received
Last updated
Start date April 2019
Est. completion date June 2020

Study information

Verified date March 2019
Source ResMed
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The AirSense 10 platform is able to detect respiratory events at night and report these data via telemonitoring. The accuracy of the AirSense 10 will be compared with scoring with polysomnography (PSG). 100 patients will be observed in a sleep facility under PSG and AirSense treatment.


Description:

Sleep disordered breathing is commonly assessed by calculating an Apnea-Hypopnea-Index AHI and a Hypopnea-Index HI to define how frequent breathing or breathing efforts stop during the night. The severity of sleep apnea (SA) is determined by the number of occurring apneas and hypopneas. The respiratory disturbance index (RDI) captures these events and is calculated comprising an AHI but also RERAs via the flow signal. Polysomnography (PSG) is being used in the sleep laboratory as the Gold standard method to document a patient`s sleep behavior by tracking air flow, respiratory effort, blood oxygen and electrocardiac as well as electromyographic signals. This way a comprehensive sleep pattern analysis can be created and different forms of SA can be detected. However, the method is laborious and cost-intensive, so it could save time and costs to have events accurately scored by the device itself. Device data become important when tracking a patient`s sleep night by night and not only once. Reliable sleep data can be a valuable tool for tailoring sleep therapy to specific patient`s needs. Accurate device data also build the foundation for analysis of large amounts of data, which can help us understanding how sleep disorders develop.


Recruitment information / eligibility

Status Withdrawn
Enrollment 0
Est. completion date June 2020
Est. primary completion date March 2020
Accepts healthy volunteers No
Gender All
Age group 18 Years to 99 Years
Eligibility Inclusion Criteria:

1. Patients aged =18 years who are able to understand and follow the instructions of the study personnel

2. Patients with an indication for PAP therapy or currently adherent to PAP therapy (device usage =4 h/ night) for moderate to severe sleep apnoea and diagnostic AHI ?15/h and/or a residual CAI ?5/h

3. Patients with currently titrated fixed CPAP pressure =8 cmH2O; or 95th percentile APAP pressure =8 cmH2O; or ASV therapy with a 95th percentile IPAP of =8 cmH2O

4. Patients who are established PAP users (PAP use duration =6 weeks)

5. Dated and signed written informed consent

Exclusion Criteria:

1. Patients with moderate to severe obstructive airway disease and/or respiratory insufficiency

2. Patients with heart failure in NYHA class III or IV, unstable hypertension, paroxysmal/persistent atrial fibrillation, unstable angina pectoris, cardiac or cerebral ischemic events within the last 6 months before screening

3. Patients with current primary or secondary insomnia

4. Patients who are pregnant or breastfeeding

5. Patients who are physically unable to comply with the protocol

Study Design


Related Conditions & MeSH terms


Intervention

Device:
AirSense 10 AutoSet for Her
Positive airway pressure

Locations

Country Name City State
Germany Schlaf- und Beatmungszentrum Blaubeuren Blaubeuren Baden-Wuerttemberg
Germany Ruhrlandklinik Essen Essen Nordrhein-Westfalen

Sponsors (1)

Lead Sponsor Collaborator
ResMed

Country where clinical trial is conducted

Germany, 

References & Publications (2)

Berry RB, Budhiraja R, Gottlieb DJ, Gozal D, Iber C, Kapur VK, Marcus CL, Mehra R, Parthasarathy S, Quan SF, Redline S, Strohl KP, Davidson Ward SL, Tangredi MM; American Academy of Sleep Medicine. Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med. 2012 Oct 15;8(5):597-619. doi: 10.5664/jcsm.2172. — View Citation

Pépin JL, Guillot M, Tamisier R, Lévy P. The upper airway resistance syndrome. Respiration. 2012;83(6):559-66. doi: 10.1159/000335839. Epub 2012 Mar 1. Review. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary To evaluate the diagnostic accuracy of the AirSense 10 Apnea-Hypopnea-Index (AHI) algorithm compared to polysomnography (PSG) scored AHI. Calculate accuracy of the device when scoring Apnoeas and Hypopneas by comparing to polysomnography scoring. Identify Apneas (at least 90% decrease of airflow for at least 10 seconds) and Hypopneas (decrease of airflow by at least 30% for at least 10 seconds accompanied by a reduction of Oxygen Saturation of 4%) and calculate the apnea-hypopnea-index (AHI): (apneas + hypopneas)/hours of sleep. 1 night
Secondary To evaluate the diagnostic accuracy of the AirSense 10 Apnea-Hypopnea-Index (AHI) detection compared to polysomnography (PSG) gold standard scored AHI for clinical relevant threshold values. For secondary endpoint different cut-off values of AHI will be used to determine the accuracy at clinical relevant thresholds. To calculate device AHI accuracy compared to PSG AHI, receiver-operator-curves will be created and sensitivity and specificity calculated based on an AHI cut-off of 5, 15 or 30. 1 night
Secondary To evaluate the diagnostic accuracy of the AirSense 10 Obstructive Apnea-Index (OAI) detection compared to polysomnography (PSG) gold standard scored OAI. Calculate accuracy of the device when scoring obstructive apnoeas by comparing to polysomnography scoring. Identify Apneas (at least 90% decrease of airflow for at least 10 seconds) and calculate the obstructive apnea-index (OAI): (apneas)/hours of sleep. 1 night
Secondary To evaluate the diagnostic accuracy of the AirSense 10 Central Apnea-Index (CAI) detection compared to polysomnography (PSG) gold standard scored CAI. Calculate accuracy of the device when scoring central apnoeas by comparing to polysomnography scoring. Identify Apneas (at least 90% decrease of airflow for at least 10 seconds) and calculate the central apnea-index (CAI): (apneas)/hours of sleep. 1 night
Secondary To evaluate the diagnostic accuracy of the AirSense 10 Respiratory-Disturbance-Index (RDI) detection compared to polysomnography (PSG) gold standard scored RDI. Calculate accuracy of the device when scoring respiratory disturbances by comparing to polysomnography scoring. Identify Apneas (at least 90% decrease of airflow for at least 10 seconds) and hypopneas (at least 90% decrease of airflow for at least 10 seconds) with a 3%drop in Oxygen saturation from baseline Level, and RERAs (flow Limitation that does not Count as an hypopnea) and calculate the respiratory disturbance-index (RDI): (apneas + hypopneas + RERAs)/hours of sleep. 1 night
Secondary Evaluate the diagnostic accuracy of the AirSense 10 Respiratory Effort Related Arousals (RERA) detection compared to polysomnography (PSG) gold standard scored RERA. Calculate accuracy of the device when scoring RERAs by comparing to polysomnography scoring RERAs. Identify RERAs (flow Limitation that does not Count as an hypopnea) and calculate the RERA-Index: RERAs/hours of sleep. 1 night
Secondary To evaluate the diagnostic accuracy of AirView AHI reporting compared to reporting via ResScan (SD card data) AirView is a cloud-based ResMed telemonitoring platform where sleep data can be transferred remotely, displayed and analysed. ResScan is an analysis and reporting software, where device data from the memory card is being uploaded. 1 night
Secondary To evaluate the diagnostic accuracy of AirView RDI reporting compared to reporting via ResScan (SD card data). AirView is a cloud-based ResMed telemonitoring platform where sleep data can be transferred remotely, displayed and analysed. ResScan is an analysis and reporting software, where device data from the memory card is being uploaded. 1 night
Secondary Sensitivity, specificity and accuracy of the sleep state detection algorithm of the AirSense10 for Her Identify the sleep stage: Stage W (wakefulness), stage N1 (NREM1), stage N2 (NREM2), stage N3 (NREM3) and stage R (REM) 1 night
Secondary Sensitivity, specificity and accuracy of sleep efficiency as derived from the sleep state detection algorithm of the AirSense10 for Her Calculate sleep efficiency by dividing minutes of sleep by minutes of time in bed 1 night
See also
  Status Clinical Trial Phase
Completed NCT05582070 - Effect on Sleep of Surgical Treatment of Severe Nasal Obstruction N/A
Recruiting NCT03919955 - A Novel Pharmacological Therapy for Obstructive Sleep Apnea Phase 2
Completed NCT03927547 - Sleep Disordered Breathing and Cardiopulmonary Disease in Peruvian Highlanders N/A
Recruiting NCT04007380 - Psychosocial, Cognitive, and Behavioral Consequences of Sleep-disordered Breathing After SCI N/A
Completed NCT02188498 - Electrocardiography Data Analysis in Sleep Disorders
Completed NCT01503164 - Effects of Continuous Positive Airway Pressure (CPAP) on Glucose Metabolism N/A
Recruiting NCT00747890 - Surgical Treatment of Mild Obstructive Sleep Apnea N/A
Active, not recruiting NCT00738179 - Continuous Positive Airway Pressure Treatment of Obstructive Sleep Apnea to Prevent Cardiovascular Disease Phase 3
Completed NCT00841906 - Alice PDx User/Validation Extended Trial N/A
Completed NCT00202501 - Usefulness of Nasal Continuous Positive Airway Pressure (CPAP) Treatment in Patients With a First Ever Stroke and Sleep Apnea Syndrome N/A
Completed NCT00047463 - Effects of Treating Obstructive Sleep Apnea in Epilepsy Phase 2
Not yet recruiting NCT06029881 - Portable System for Non-intrusive Monitoring of Sleep
Recruiting NCT06093347 - Central Apnoea Monitor Study
Terminated NCT05445869 - Severe OSA Study (SOS) N/A
Withdrawn NCT04096261 - The Importance of Sleep Quality and the Blood-brain Barrier in Cognitive Disorders and Alzheimer's Disease
Recruiting NCT04575740 - Phenotyping Mechanistic Pathways for Adverse Health Outcomes in Sleep Apnea N/A
Completed NCT04676191 - Validation of a Contactless Vital Signs Measurement Sensor N/A
Recruiting NCT06015620 - Comorbidities Resolution After MGB Surgery and Change in Body Composition
Completed NCT06051097 - Metabolic Syndrome and Obstructive Sleep Apnea
Completed NCT05687097 - Untreated Sleep Apnea as an Aggravating Factor for Other Secondary Medical Conditions After Spinal Cord Injury