View clinical trials related to Sick Sinus Syndrome.
Filter by:This clinical investigation is a prospective, single-blinded, randomized trial. The primary objective concerns the safety and effectiveness of the AAIsafeR mode with the preventive algorithms.
The aim of the study is the comparison of two different leads in their capabilities to detect episodes and duration of paroxysmal atrial fibrillation (AF) and atrial tachyarrhythmia (AT), and the rejection of far field sensing of the far field R-wave (FFRW).
The purpose of this study is to document the number of falls and fractures in Sinus Node Disease (SND) patients.
The purpose of this observational study is to collect data regarding the population of patients with a pacemaker implanted.
A consequence of chronic RV pacing is a process of electrical remodeling that alters myocardial repolarization to reflect the altered depolarization induced by the RV lead. When RV pacing is discontinued, the altered repolarization persists for several weeks. This phenomena is traditionally described as "T-wave memory" based upon the 12-lead ECG appearance of inverted T-Waves. The investigators are using the ECGI technique to produce three dimensional electroanatomical images of this phenomena in patients with dual chamber pacemakers. Echocardiography will also be used to image the mechanical effects of RV pacing and T-wave memory. The images will show the spatial distribution of altered repolarization and allow us to correlate any mechanical consequences of this phenomena that may exist.
The aim of the study is to evaluate the impact of atrial fibrillation ablation in patients presenting a brady-tachy syndrome on the AF burden. The hypothesis of the study is that AF ablation prevents not only from AF episodes recurrence but also from bradycardic episodes.
To generate a list of potential genetic markers that correlate with an increased risk of life-threatening arrhythmias. To evaluate ECG-based risk markers such as heart rate variability and T-wave Alternans for their association with arrhythmic events.
In case of sinus node dysfunction, it is often necessary to choose the safer option provided by a DDD pacemaker even though the most appropriate mode of pacing is AAI mode. In addition to saving energy, the latter mode allows spontaneous ventricular activation, the haemodynamic consequences of which are, in most cases, better than those obtained with dual chamber pacing. Recent studies as the MOST study suggest also that ventricular desynchronization imposed by right ventricular apical pacing even when AV synchrony is preserved increases the risk of atrial fibrillation in patients with SND. Similar results were already given by anterior studies (PIPAF) which, taking into account the percentage of ventricular pacing, suggested that AF prevention algorithm in combination with a preserved native conduction are efficient in reducing AF burden. However, current practice is to implant a dual chamber pacemaker to prevent the risk of atrioventricular block (AVB) even if DDDR pacing with a fixed long AV delay was found inefficient in reducing ventricular pacing and was associated with a high risk of arrhythmias. The Symphony 2550 cardiac pacemaker offers pacing modes that automatically switch from AAI(R) mode to DDD(R) or DDI(R) in event of severe atrioventricular conduction disorder, irrespective of whether or not these are accompanied by an atrial arrhythmia, returning spontaneously to AAI(R) mode as soon as the spontaneous AV conduction has resumed. These 2 particular modes are called the AAI SafeR and DDD/AMC (R) mode. The main differences between both modes are that (i) AAI SafeR does not trigger any AV Delay after a sensed or paced atrial event which allows long PR intervals or even limited ventricular pauses with no switch to DDD(R), while (ii) DDD/AMC (R) is able to optimize AV Delay after switching to DDD(R) according to measured spontaneous conduction times and to provide an acceleration in case of vaso-vagal syndrome. This pacing mode has previously been assessed in clinical studies. This study intends to demonstrate that the automatic modes switching significantly reduce the percentage of ventricular pacing in patients implanted with a spontaneous AV conduction and reduce the occurrence of atrial arrhythmias, on a mid-term follow-up period, in comparison to standard DDD pacing with long AVDelay.
This is a an investigator-initial, multicenter, open-label, randomized, parallel-group comparative study to evaluate the effect on the incidence of AF and pacemaker dependence in SSS patients receiving physiological atrial-based pacing alone or adding losartan 100mg to physiological atrial-based pacing treatment. The duration of the study will be approximately 13 months, comprising 4-week pre-study period, and 12-month treatment period.
Prospective study assessing the incidence of atrial high rate episodes (AHRE) in pacemaker patients with and without previously diagnosed AT.