Shoulder Dislocation Clinical Trial
Official title:
Absorption Rate and Bone Ingrowth of Absorbable Anchors Used in Shoulder Dislocation
This study aims to analyze the absorption rate of Pushlock anchors and Gryphon anchors and the bone ingrowth of the anchor channel by consulting the postoperative CT images of patients with recurrent shoulder dislocation completed by myself. The investigators will analyze the influence factors of anchor absorption and bone ingrowth, which will provide a reference for improving anchor design and the improvement of surgical techniques.
"Recurrent anterior dislocation of the shoulder joint is a common disease of the shoulder joint. The standard treatment methods include soft tissue repair surgery and bone tissue repair surgery. The former refers to arthroscopic labral suture (Bankart repair surgery), and the latter includes Latarjet surgery, Bristow surgery and Cuistow surgery pioneered by our team. Whether it is soft tissue repair surgery or bone tissue repair surgery, anchors are required for suture fixation during the operation. The anchors currently in use include non-absorbable anchors and absorbable anchors. Non-absorbable anchors include metal anchors and peek material anchors, which remain in the body forever after the operation and cannot be absorbed. The absorbable anchors, in theory, will be absorbed 2 years after surgery. Non-absorbable anchors have inherent limitations that limit their use. If the non-absorbable anchor loosens and shifts, it can cause severe cartilage damage. If complications such as re-dislocation occurred, revision surgery is required. Revision surgery is complicated because the non-absorbable anchor inserted in the initial surgery occupies the best anchor position. Metal anchors can cause artifacts and affect postoperative MRI imaging. Therefore, absorbable anchors have gradually become routinely used in shoulder joint dislocation surgery. The anchors currently used in our hospital for shoulder joint instability include Pushlock anchors from Arthrex and Gryphon anchors from Depuy Mitek. The materials are PLLA/β-TCP and PLGA/β-TCP. The absorption anchor starts to absorb in 1 year and completes absorption in about two years. The anchor tunnel will be filled with bone tissue. However, the investigators have found that the anchor cannot be wholly absorbed as scheduled. During the revision surgery, the original absorbable anchor can still be seen. Clear anchor tunnels can also be seen in CT films after 2 years postoperatively. Published literature also show that the degradation rate of absorbable anchors is not the same. The literature report that anchors have not completed degradation and bone ingrowth within the time advertised by the manufacturers. In summary, this study aims to analyze the absorption rate of Pushlock anchors and Gryphon anchors and the bone ingrowth of the anchor tunnel by consulting the postoperative CT films of subjects with recurrent shoulder dislocation completed by myself. The factors that affect anchor absorption and bone ingrowth provide a reference for improving anchor design and the improvement of surgical techniques. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT05635240 -
Chronic Anterior Shoulder Instability in the Military
|
||
Recruiting |
NCT02913352 -
Latarjet Versus Modified Eden-Hybinette for Anterior Shoulder Dislocation
|
N/A | |
Completed |
NCT03154957 -
Management of Acute Dislocation of Emergency in the University Hospital of Strasbourg Shoulder: Retrospective Evaluation of Practices and Proposal of a Clinical Path
|
||
Recruiting |
NCT02510625 -
The Arthroscopic Treatment of Recurrent Anterior Shoulder Instability
|
N/A | |
Completed |
NCT00707018 -
Immobilization in External Rotation After First Time Anterior Shoulder Dislocation
|
N/A | |
Recruiting |
NCT04887337 -
Early arthroscoPic Stabilization veRsus rehabilitatiOn of the Shoulder in Adolescents With a trauMatic First-time Anterior Shoulder Dislocation ePisode
|
N/A | |
Completed |
NCT04960137 -
Shoulder Dislocations Treated With Button Plates and Non-absorbable Suture Anchor
|
N/A | |
Recruiting |
NCT05388942 -
Virtual Reality Hypnosis Versus Inhaled Nitrous Oxide in Anterior Shoulder Dislocation Reduction: an Open Multicenter Randomized Controlled Trial
|
N/A | |
Completed |
NCT02725333 -
Does Shoulder Stabilizations Stabilize Shoulders?
|
N/A | |
Recruiting |
NCT05705479 -
Shoulder Instability Trial Comparing Arthroscopic Stabilization Benefits Compared With Latarjet Procedure Evaluation - STABLE Definitive Trial
|
N/A | |
Not yet recruiting |
NCT05048303 -
Multicenter Clinical Cohort Study of Modified Flexible Fixation Latarjet Procedure for Recurrent Shoulder Dislocation
|
N/A | |
Recruiting |
NCT03453710 -
Remplissage Versus Latarjet Coracoid Transfer for Recurrent Shoulder Instability
|
N/A | |
Recruiting |
NCT04952636 -
A Prospective Comparative Study of Arthroscopic and Open Surgery in Cuistow Procedure
|
N/A | |
Completed |
NCT00251264 -
Arthroscopic Versus Open Stabilization for Traumatic Shoulder Instability
|
N/A | |
Terminated |
NCT02426996 -
The Latarjet-type Procedure Using the SEM Positioner: Using a Scan to Assess Consolidation
|
N/A | |
Completed |
NCT04022629 -
ASSET 2 Study: Long-Term Follow-up of a Randomised Control Trial
|
Phase 2/Phase 3 | |
Terminated |
NCT04820491 -
Efficient Anterior Shoulder Ultrasound Reduction Multicenter Prospective Randomized Trial
|
N/A | |
Recruiting |
NCT05443295 -
Improvement of Fatigue in Unstable Shoulder Through a Therapeutic Exercise Program in Physiotherapy
|
N/A | |
Completed |
NCT06459258 -
Throwing Velocity and Patient Reported Outcomes in Elite Level Handball Players After Completion of Shoulder-Pacemaker Strength Training
|
N/A | |
Completed |
NCT04479397 -
Sling vs Nothing After Latarjet Procedure
|
N/A |