Administrative data

NCT number NCT04977505
Other study ID # M2021132
Secondary ID
Status Completed
Phase
First received
Last updated
Start date April 21, 2021
Est. completion date May 28, 2021

Study information

Verified date June 2021
Source Peking University Third Hospital
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

This study aims to analyze the absorption rate of Pushlock anchors and Gryphon anchors and the bone ingrowth of the anchor channel by consulting the postoperative CT images of patients with recurrent shoulder dislocation completed by myself. The investigators will analyze the influence factors of anchor absorption and bone ingrowth, which will provide a reference for improving anchor design and the improvement of surgical techniques.


Description:

"Recurrent anterior dislocation of the shoulder joint is a common disease of the shoulder joint. The standard treatment methods include soft tissue repair surgery and bone tissue repair surgery. The former refers to arthroscopic labral suture (Bankart repair surgery), and the latter includes Latarjet surgery, Bristow surgery and Cuistow surgery pioneered by our team. Whether it is soft tissue repair surgery or bone tissue repair surgery, anchors are required for suture fixation during the operation. The anchors currently in use include non-absorbable anchors and absorbable anchors. Non-absorbable anchors include metal anchors and peek material anchors, which remain in the body forever after the operation and cannot be absorbed. The absorbable anchors, in theory, will be absorbed 2 years after surgery. Non-absorbable anchors have inherent limitations that limit their use. If the non-absorbable anchor loosens and shifts, it can cause severe cartilage damage. If complications such as re-dislocation occurred, revision surgery is required. Revision surgery is complicated because the non-absorbable anchor inserted in the initial surgery occupies the best anchor position. Metal anchors can cause artifacts and affect postoperative MRI imaging. Therefore, absorbable anchors have gradually become routinely used in shoulder joint dislocation surgery. The anchors currently used in our hospital for shoulder joint instability include Pushlock anchors from Arthrex and Gryphon anchors from Depuy Mitek. The materials are PLLA/β-TCP and PLGA/β-TCP. The absorption anchor starts to absorb in 1 year and completes absorption in about two years. The anchor tunnel will be filled with bone tissue. However, the investigators have found that the anchor cannot be wholly absorbed as scheduled. During the revision surgery, the original absorbable anchor can still be seen. Clear anchor tunnels can also be seen in CT films after 2 years postoperatively. Published literature also show that the degradation rate of absorbable anchors is not the same. The literature report that anchors have not completed degradation and bone ingrowth within the time advertised by the manufacturers. In summary, this study aims to analyze the absorption rate of Pushlock anchors and Gryphon anchors and the bone ingrowth of the anchor tunnel by consulting the postoperative CT films of subjects with recurrent shoulder dislocation completed by myself. The factors that affect anchor absorption and bone ingrowth provide a reference for improving anchor design and the improvement of surgical techniques.


Recruitment information / eligibility

Status Completed
Enrollment 114
Est. completion date May 28, 2021
Est. primary completion date May 28, 2021
Accepts healthy volunteers No
Gender All
Age group N/A and older
Eligibility Inclusion Criteria: - (1) The subject underwent Cuistow surgery, Bristow surgery, Latarjet surgery or Bankart surgery. - (2) The surgeon was chief physician Cui Guoqing. - (3) Pushlock anchor (2.9mm) or Gryphon anchor (3.0mm) was used during the operation, and the placement position was the glenoid. Exclusion Criteria: - (1) Ipsilateral shoulder joint, with a history of surgery. - (2) Subjects with postoperative infection. - (3) Subjects with incomplete data (no immediate postoperative CT or no postoperative CT films for more than 2 years). - (4)Subjects with diabetes. - (5)Revision surgery for shoulder dislocation.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
pushlock
The surgery procedure was performed with pushlock for fixation
gryphon
The surgery procedure was performed with Gryphon for fixation

Locations

Country Name City State
China PekingUTH Beijing Beijing

Sponsors (1)

Lead Sponsor Collaborator
Peking University Third Hospital

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Primary hounsfield unit of anchor tunnel It is an index used to evaluate the status of bone resorption. It was recorded of last CT films. 2 years after surgery
Primary the diameter of anchor tunnel It is an index used to evaluate the status of bone resorption. It can be measured in the last CT films. 2 years after surgery
Primary Hounsfield unit of ossification site It is an index used to evaluate the status of bone resorption. It was recorded of last CT films. 2 years after surgery
Secondary unossified area of anchor tunnel It is an index used to evaluate the status of bone resorption. It can be measured in the last CT films. 2 years after surgery
Secondary ossification quality score It is a standard score used to qualify the status of ossification. 2 years after surgery
See also
  Status Clinical Trial Phase
Not yet recruiting NCT05635240 - Chronic Anterior Shoulder Instability in the Military
Recruiting NCT02913352 - Latarjet Versus Modified Eden-Hybinette for Anterior Shoulder Dislocation N/A
Completed NCT03154957 - Management of Acute Dislocation of Emergency in the University Hospital of Strasbourg Shoulder: Retrospective Evaluation of Practices and Proposal of a Clinical Path
Recruiting NCT02510625 - The Arthroscopic Treatment of Recurrent Anterior Shoulder Instability N/A
Completed NCT00707018 - Immobilization in External Rotation After First Time Anterior Shoulder Dislocation N/A
Recruiting NCT04887337 - Early arthroscoPic Stabilization veRsus rehabilitatiOn of the Shoulder in Adolescents With a trauMatic First-time Anterior Shoulder Dislocation ePisode N/A
Completed NCT04960137 - Shoulder Dislocations Treated With Button Plates and Non-absorbable Suture Anchor N/A
Recruiting NCT05388942 - Virtual Reality Hypnosis Versus Inhaled Nitrous Oxide in Anterior Shoulder Dislocation Reduction: an Open Multicenter Randomized Controlled Trial N/A
Completed NCT02725333 - Does Shoulder Stabilizations Stabilize Shoulders? N/A
Recruiting NCT05705479 - Shoulder Instability Trial Comparing Arthroscopic Stabilization Benefits Compared With Latarjet Procedure Evaluation - STABLE Definitive Trial N/A
Not yet recruiting NCT05048303 - Multicenter Clinical Cohort Study of Modified Flexible Fixation Latarjet Procedure for Recurrent Shoulder Dislocation N/A
Recruiting NCT03453710 - Remplissage Versus Latarjet Coracoid Transfer for Recurrent Shoulder Instability N/A
Recruiting NCT04952636 - A Prospective Comparative Study of Arthroscopic and Open Surgery in Cuistow Procedure N/A
Completed NCT00251264 - Arthroscopic Versus Open Stabilization for Traumatic Shoulder Instability N/A
Terminated NCT02426996 - The Latarjet-type Procedure Using the SEM Positioner: Using a Scan to Assess Consolidation N/A
Completed NCT04022629 - ASSET 2 Study: Long-Term Follow-up of a Randomised Control Trial Phase 2/Phase 3
Terminated NCT04820491 - Efficient Anterior Shoulder Ultrasound Reduction Multicenter Prospective Randomized Trial N/A
Recruiting NCT05443295 - Improvement of Fatigue in Unstable Shoulder Through a Therapeutic Exercise Program in Physiotherapy N/A
Completed NCT04479397 - Sling vs Nothing After Latarjet Procedure N/A