Clinical Trials Logo

Clinical Trial Summary

Objective: To compare two de-escalation strategies guided by either extravascular lung water or global end-diastolic volume-oriented algorithms in patients with sepsis and ARDS. Design: A prospective randomized study. Setting: City Hospital #1 of Arkhangelsk, Russia, mixed ICU. Patients: Sixty patients with sepsis and ARDS were randomized to receive de-escalation fluid therapy, guided either by extravascular lung water index (EVLWI, n = 30) or global end-diastolic volume index (GEDVI, n = 30). Intervention: In case of GEDVI > 650 mL/m2 or EVLWI > 10 mL/kg, diuretics and/or controlled ultrafiltration were administered. The primary goal of de-escalation was to achieve the cumulative 48-hr fluid balance in the range of 0 to - 3000 mL. If GEDVI < 650 mL/m2 or EVLWI < 10 mL/kg, the target fluid balance was set from 0 to +3000 mL.


Clinical Trial Description

In all patients, investigators catheterized the internal jugular or the subclavian vein with a triple-lumen central venous catheter (Certofix, B|Braun, Germany) and the femoral artery with a thermistor-tipped arterial catheter (5F, PV2015L20, Pulsion Medical Systems, Munich, Germany). The arterial blood pressure was recorded from a side port of the catheter. Hemodynamic monitoring was carried out using the method of transpulmonary thermodilution (PiCCO2 monitor, Pulsion Medical Systems, Germany) by a triplicate 15 mL bolus of cold (< 8 °C) 0.9% saline solution. Mechanical ventilation (Puritan Bennett 840 and 980, Medtronic, USA) was performed according to the ARDS Network protocol, using pressure-controlled ventilation with tidal volume 6-7 ml/kg of predicted body weight, with a Ppeak not exceeding 35 cm H2O, positive end-expiratory pressure (PEEP) and a fraction of inspiratory oxygen (FiO2) levels adjusted to maintain SpO2 within a 92-97% range. The target fluid balance was achieved by continuous infusion of furosemide with an initial dose of 0.07 mcg/kg/hr and a minimal duration of 12 hrs. In case of failure to reach a negative fluid balance by means of diuretics, started controlled ultrafiltration using continuous veno-venous hemofiltration (CVVH, multiFiltrate, Fresenius Medical Care, Germany). For fluid replacement, if necessary, investigators administered balanced crystalloid solutions (Sterofundin Iso/G5, B|Braun, Germany) with an initial infusion rate of 6-7 ml/kg/hr. Heart rate (HR), MAP, cardiac index (CI), GEDVI, EVLWI, pulmonary vascular permeability index (PVPI), central venous pressure (CVP), systemic vascular resistance index (SVRI), pulse pressure variation (PPV), and stroke volume variation (SVV) were assessed using transpulmonary thermodilution and arterial pulse contour analysis. During the study, investigators also assessed blood gases (ABL Flex 800 Radiometer, Denmark) and biochemical parameters (Random Access A-25, BioSystems, Spain). All measurements were performed at baseline, at 24 and at 48 hrs of the goal-directed de-escalation ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04508296
Study type Interventional
Source Northern State Medical University
Contact
Status Completed
Phase N/A
Start date March 10, 2016
Completion date December 10, 2020

See also
  Status Clinical Trial Phase
Not yet recruiting NCT05306392 - Effects of Induced Moderate Hypothermia on ARDS Patients Under Venovenous ExtraCorporeal Membrane Oxygenation N/A
Completed NCT04719182 - Practice of Adjunctive Treatments in Intensive Care Unit Patients With COVID-19
Terminated NCT04954014 - Pilot Study of Single Dose Bevacizumab as Treatment for Acute Respiratory Distress Syndrome (ARDS) in COVID-19 Patients Phase 2
Completed NCT04274296 - Advisory Lead ARDS Respirator Management
Recruiting NCT03215316 - Screening Expiratory Flow Limitation by Flow-time Curve N/A
Recruiting NCT04115514 - Treatment of ARDS With Instilled T3 Phase 2
Not yet recruiting NCT05061212 - The Mechanism of Extracellular Vesicles Containing Mitochondrial DNA in ARDS Lung Injury Caused by Extrapulmonary Sepsis
Not yet recruiting NCT04556864 - Hemodynamic Impact on Critical Care Patients With Lung Damage Secondary to COVID-19
Completed NCT05693051 - Use of Prone Position Ventilation in Danish Patients With COVID-19 Induced Severe ARDS Treated With VV-ECMO
Recruiting NCT04174014 - Optimal PEEP Titration Combining Transpulmonary Pressure Measurement and Electric Impedance Tomography N/A
Enrolling by invitation NCT06164639 - Potential Biomarkers for Reflux Aspiration-induced Lung Injury.
Terminated NCT05384379 - Efficacy and Safety Evaluation of BZ371B in ARDS Patients Early Phase 1
Completed NCT04375735 - London's Exogenous Surfactant Study for COVID19 Phase 1/Phase 2
Completed NCT06224010 - Respiratory Drive and Inspiratory Effort in COVID-19 Associated ARDS
Not yet recruiting NCT04530188 - Effects of Sevoflurane on Extravascular Lung Water and Pulmonary Vascular Permeability in Patients With ARDS Phase 3
Completed NCT03405038 - Prone Position Impact in ARDS Patients on the Incidence of Central Venous Catheter Colonization
Recruiting NCT05148026 - Regional Citrate Anticoagulation for RRT During V-V ECMO N/A
Recruiting NCT04390360 - Smartphone Application for Initiation of Protective Ventilation. Clinical Impact of Instrumental Dead Space Reduction N/A
Completed NCT06197256 - Cardiac Dysfunction in Critically Ill Covid-19 Patients
Completed NCT04008225 - Study of the Effects of Bronchoalveolar Lavage Liquid in the ARDS on the Functioning of the Neutrophil Polynuclear System