Clinical Trials Logo

Clinical Trial Summary

Preterm and term intubuted infants in the NICU will undergo two sequential suctioning procedures: a new, FDA-approved suction device called EXSALTA (ED) and the standard conventional wall (SCW). The physiological consequences, i.e. changes in heart rate (HR), oxygen saturation (SpO2), cerebral oxygenation (C-rSO2), and cerebral fractional oxygen extraction (C-FOE) between ED and SCW ETT tracheal suctioning system in both open and closed catheter system settings will be evaluated using a randomized cross over design in preterm and term infants receiving mechanical ventilation via an ETT. This study will evaluate the hypothesis that there will be significantly lower variations in HR, SpO2, C-rSO2, and C-FOE during ETT suctioning with ED compared to SCW suctioning systems under both open and close ETT suction settings.


Clinical Trial Description

Respiratory failure in neonates frequently requires mechanical ventilation through an endotracheal tube (ETT). The presence of an ETT inhibits the infant's intrinsic ability to clear endogenous lung secretions effectively with compromised glottic closure and impaired muccociliary function, and thus regular supportive suctioning of the ETT is essential. The benefits of patent airway are evident, but adverse effects may also result from suctioning which are especially deleterious in extremely preterm infants with immature pulmonary and systemic hemodynamic function. These adverse effects include transient hypoxemia and oxygen desaturation, vasovagal reactions, altered central and cerebral hemodynamics, atelectasis, pneumothorax, and mucosal damage. The cardiorespiratory instability during ETT suctioning is partially attributed to alveolar decruitment and loss of lung volume from disconnecting the ETT from the ventilator circuit and negative suction pressure. Maintenance of lung volume is essential to optimize gas exchange and prevent ventilator induced lung injury. The magnitude of lung volume loss is related to catheter size and applied suctioning pressure and flow, highlighting the complexity of interaction between suction technique, lung mechanics and disease state. In accordance with industry standard codes, a high flow rate is essential to ensure the rapid removal of fluid and secretions from the desired site and the standard conventional wall (SCW) suction outlets provide a minimum flow of approximately 85 liters per minute. Such high flows can lead to endotracheal suctioning-induced alveolar decruitment that may of significant clinical relevance. Recently, a low flow technology suction device EXSALTA (ED) for clearing ETT secretions in patients on ventilators has been approved by FDA. The device uses peristaltic action to move fluids from the patient to a collection canister at a fixed flow rate of 1.4 L/min and eliminates the uncontrolled flow of air from the patient's lungs. The user selects a desired pressure level that is independent of the flow rate, a feature unavailable with SCW wall suction equipment used at patient's bedside. This exceptional microprocessor-controlled tabletop suction device, available at any suction setting, reduces risk of negative pressures in the lungs to help prevent alveolar collapse and hypoxia associated with standard suctioning techniques. This study will examine the hypothesis that there will be significantly lower variations in heart rate (HR), oxygen saturation (SpO2), cerebral oxygenation (C-rSO2), and cerebral fractional oxygen extraction (c-FOE) with ED compared to SCW suction system during open or closed ETT suctioning. To test this hypothesis, the physiological consequences of two ETT suctioning systems in preterm and term infants will be evaluated using the following aims: AIM 1. To compare the variations in HR (bpm), SpO2 (%), C-rSO2 (%), C-FOE (%) between ED and SCW suctioning systems during routine standard care open and closed ETT suctioning. AIM II. To compare the incidence (episodes) of cardiorespiratory disturbances, i.e. bradycardia (HR<80 bpm) and/or hemoglobin oxygen desaturation (SpO2) < 80% for more than 10s during suctioning with ED and SCW suctioning system during routine standard care open and closed ETT suctioning. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06443970
Study type Interventional
Source Columbia University
Contact Rakesh Sahni, MD
Phone 212-305-9743
Email rs62@cumc.columbia.edu
Status Not yet recruiting
Phase N/A
Start date June 30, 2024
Completion date October 31, 2025

See also
  Status Clinical Trial Phase
Completed NCT03909854 - Pragmatic Investigation of Volume Targeted Ventilation-1 N/A
Recruiting NCT03662438 - HOPE (Home-based Oxygen [Portable] and Exercise) for Patients on Long Term Oxygen Therapy (LTOT) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT05535543 - Change in the Phase III Slope of the Volumetric Capnography by Prone Positioning in Acute Respiratory Distress Syndrome
Completed NCT04030208 - Evaluating Safety and Efficacy of Umbulizer in Patients Requiring Intermittent Positive Pressure Ventilation N/A
Recruiting NCT04542096 - Real Time Evaluation of Dynamic Changes of the Lungs During Respiratory Support of VLBW Neonates Using EIT
Recruiting NCT04668313 - COVID-19 Advanced Respiratory Physiology (CARP) Study
Recruiting NCT05883137 - High-flow Nasal Oxygenation for Apnoeic Oxygenation During Intubation of the Critically Ill
Completed NCT04505592 - Tenecteplase in Patients With COVID-19 Phase 2
Completed NCT03943914 - Early Non-invasive Ventilation and High-flow Nasal Oxygen Therapy for Preventing Delayed Respiratory Failure in Hypoxemic Blunt Chest Trauma Patients. N/A
Active, not recruiting NCT03472768 - The Impact of Age-dependent Haptoglobin Deficiency on Plasma Free Hemoglobin Levels During Extracorporeal Membrane Oxygenation Support
Not yet recruiting NCT04538469 - Absent Visitors: The Wider Implications of COVID-19 on Non-COVID Cardiothoracic ICU Patients, Relatives and Staff
Not yet recruiting NCT02542423 - Endocan Predictive Value in Postcardiac Surgery Acute Respiratory Failure. N/A
Completed NCT02265198 - Relationship of Pulmonary Contusion to Pulmonary Inflammation and Incidence of Acute Respiratory Distress Syndrome N/A
Completed NCT01885442 - TryCYCLE: A Pilot Study of Early In-bed Leg Cycle Ergometry in Mechanically Ventilated Patients N/A
Completed NCT02105298 - Effect of Volume and Type of Fluid on Postoperative Incidence of Respiratory Complications and Outcome (CRC-Study) N/A
Completed NCT02814994 - Respiratory System Compliance Guided VT in Moderate to Severe ARDS Patients N/A
Completed NCT01659268 - Performance of Baccalaureate Nursing Students in Insertion of Laryngeal Mask: a Trial in Mannequins N/A
Completed NCT01249794 - Non Invasive Ventilation After Cardiac Surgery N/A
Terminated NCT01333059 - Cycling of Sedative Infusions in Critically Ill Pediatric Patients N/A