Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02370472
Other study ID # 38067
Secondary ID
Status Completed
Phase N/A
First received February 18, 2015
Last updated March 1, 2018
Start date July 2014
Est. completion date February 2015

Study information

Verified date March 2018
Source Milton S. Hershey Medical Center
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The use of Ultrasound Guided Regional Anaesthesia (USRA) has increased over the last decade. Theoretically, ultrasound imaging may increase efficacy and safety by allowing visualization of the needle pathway and local anaesthetic spread around the nerve. In addition to knowledge of anatomy and general principles of ultrasonography, USRA requires learning new skills such as image interpretation, needle-beam alignment, and needle trajectory tracking. The hand-eye coordination required during needle advancement requires practice to master because the needle must be properly aligned with the ultrasound probe in order to maintain the needle path in the beam at all times. Adding to the difficulty, hand and needle movements can occur in three axes, but an ultrasound image is seen in only two dimensions. Since the ability to acquire the necessary skills to perform USRA is subjective and not yet validated, it is difficult to recommend a single, effective training pathway.

Currently, the only method of supervised training before performing an USRA procedure on an actual patient involves practicing needle insertion in a phantom or cadaver. Studies assessing the impact of learning using these methods are lacking. It is possible that some practitioners may choose alternative one-off learning methods. Such methods are not standardized and are thus difficult to evaluate.


Description:

This was a single site, prospective, pre-test-post-test, randomized study conducted after Institutional Review Board (IRB) approval. Thirty subjects, including medical students, practicing anaesthesiologists and anaesthesia residents in training at the Penn State Hershey Medical Center, were recruited by formal email invitation to participate. Written consent was obtained from each participant before their inclusion in the study and each participant completed a pre-study form. Once enrolled in the study, participants were given 10 minutes to familiarize themselves with both the ultrasound equipment (SonoSite, MTurbo, Bothell, WA, USA) and the phantom model (MiniSimâ„¢ Upper Extremity Series, Life tech Inc., Stafford, Texas, USA). They also viewed a pre-recorded video demonstrating the task they were to perform. As a pre-test, participants performed the required Needle Insertion Accuracy (NIA) task 3 consecutive times and were assessed using a scoring form adapted from the Mayo Clinic. After completing the pre-test, participants were randomly divided into two groups, experimental and control, by a computer-generated randomization list (SAS Institute, Cary, NC). Participants were blinded to their group assignment.

Previously, we have reported details of the new learning tool. Briefly, all spatial movements occur in three dimensions which can be labeled the x-axis, the y-axis and the z-axis. A video camera records movement in two axes. By placing a second video camera at 90 degrees to the first camera, the third axis can be recorded as well as one axis in common with the first camera. Video recordings are stored electronically on a hard-drive and can be reviewed individually or in combination, at normal speed, or slowed if necessary. Still images can also be obtained.

The experimental group was allowed to practice the same pre-test task using the same ultrasound machine and phantom model. On a single computer screen, they were able to visualize their hand and needle movements along with the position of the ultrasound probe. The control group was allowed to practice the same pre-test task using the same ultrasound machine and phantom model but without the added visual aid. Both groups were allowed to practice their pre-test tasks for a maximum of 30 minutes, and recorded their self-assessment as proficient or not proficient at that time. Both groups then performed the post-test, which was the same task used for the pre-test, and each trainee was evaluated using the same scoring tool. To avoid subjective variations and inter-rater variability, all evaluations were recorded by a single blinded investigator.

Statistical analysis Pre- and post-test mean scores (ranging from 5 to15) were analyzed using statistical methods to determine whether this new learning tool improved NIA skills required with USRA. Pre-test and post-test scores (ranging from 5 to 15) were obtained in triplicate and averaged to produce a representative assessment for each participant. The primary endpoint was change in NIA score from baseline, i.e., the score difference obtained by subtracting the mean pre-test score from the mean post-test score. A sample size of 15 subjects per group (experimental and control) provides 80% power to detect an effect size of 1, based on a two-sided t-test with a 5% error probability (calculated using G*Power version 3.1). Analysis of the primary endpoint utilized a two-sided, two-sample t-test at the 5% level of significance. Secondary analyses evaluated the intervention effect on novice trainees, and trainees with prior USRA experience. Score differences for individual NIA skills (movement, alignment, approach, target, location) were also analyzed.


Recruitment information / eligibility

Status Completed
Enrollment 30
Est. completion date February 2015
Est. primary completion date February 2015
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 25 Years to 75 Years
Eligibility Inclusion Criteria:

- Health Care professional

Exclusion Criteria:

Study Design


Related Conditions & MeSH terms


Intervention

Other:
tool developed using cameras and a computer
cameras allowing subject to be able to visualize hand and needle movements as well s the position of the transducers along with the image from the ultrasound on a computer screen

Locations

Country Name City State
United States Penn State Hershey Medical Center Hershey Pennsylvania

Sponsors (1)

Lead Sponsor Collaborator
Milton S. Hershey Medical Center

Country where clinical trial is conducted

United States, 

References & Publications (4)

Adhikary SD, Hadzic A, McQuillan PM. Simulator for teaching hand-eye coordination during ultrasound-guided regional anaesthesia. Br J Anaesth. 2013 Nov;111(5):844-5. doi: 10.1093/bja/aet364. — View Citation

Ramlogan R, Manickam B, Chan VW, Liang L, Adhikary SD, Liguori GA, Hargett MJ, Brull R. Challenges and training tools associated with the practice of ultrasound-guided regional anesthesia: a survey of the American society of regional anesthesia and pain m — View Citation

Sites BD, Chan VW, Neal JM, Weller R, Grau T, Koscielniak-Nielsen ZJ, Ivani G. The American Society of Regional Anesthesia and Pain Medicine and the European Society of Regional Anaesthesia and Pain Therapy joint committee recommendations for education an — View Citation

Smith HM, Kopp SL, Jacob AK, Torsher LC, Hebl JR. Designing and implementing a comprehensive learner-centered regional anesthesia curriculum. Reg Anesth Pain Med. 2009 Mar-Apr;34(2):88-94. doi: 10.1097/AAP.0b013e31819e734f. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Needle image accuracy score difference The experimental group was allowed to practice the same pre-test task using the same ultrasound machine and phantom model. On a single computer screen, they were able to visualise their hand and needle movements along with the position of the ultrasound probe. The control group was allowed to practice the same pre-test task using the same ultrasound machine and phantom model but without the added visual aid. Both groups were allowed to practice their pre-test tasks for a maximum of 30 minutes 30 minutes
See also
  Status Clinical Trial Phase
Recruiting NCT05944393 - Erector Spine Plane (ESP) Block for Analgesia in Pediatric Scoliosis Surgery N/A
Recruiting NCT05589246 - Regional Analgesia in Combination With Cryoanalgesia to Prevent Acute Pain Following Nuss Procedure N/A
Not yet recruiting NCT03978780 - Erector Spinae Block vs. Placebo Block Study N/A
Terminated NCT02846610 - Registry for Acute Pain Treatment
Completed NCT03679897 - Comparison of 0.375% Ropivacaine and 0.25% Levobupivacaine for Infraclavicular Brachial Plexus Block Phase 4
Recruiting NCT06014749 - Serratus Intercostal Block Versus Epidural Analgesia in Eventration: Prospective Observational Study
Completed NCT04438369 - Evaluation of Ultrasound-guided Erector Spinae Block for Postoperative Analgesia in Laprascopic Ventral Hernia Repair. N/A
Terminated NCT03500744 - Erector Spinae Plane Block for Major Gynecologic and Urologic Surgery N/A
Completed NCT05160298 - Analgesic Effect of Bilateral Erector Spinae Plane Block With Ropivacaine After Sternotomy for Cardiac Surgery Phase 2
Recruiting NCT06121726 - Predictive Factors for the Effectiveness of the Ilioinguinal Iliohypogastric Nerve Block for Hernia Surgery
Completed NCT04549090 - Ultrasound Guided Posterior Quadratus Lumborum Block for Postoperative Analgesia in Gynecologic Surgery
Completed NCT05286190 - Caudal Block and Transversus Abdominis Plane Block in Pediatric Inguinal Hernia Repair N/A
Completed NCT02200016 - Displacement of Popliteal Sciatic Nerve Catheters After Major Foot and Ankle Surgery Phase 4
Recruiting NCT06089798 - Analgesic Efficacy of Ultrasound-guided Bilateral Pecto-intercostal Plane Block in Pediatric Cardiac Surgery
Not yet recruiting NCT06115720 - Consent in Anaesthesia N/A
Completed NCT04668183 - Ultrasound-guided PNB and DPNB for Pediatric Distal Hypospadias Surgery
Completed NCT05344105 - Comparison of Postoperative Analgesic Efficacy of Transversalis Fascia Plan Block and Erector Spina Plan Block N/A
Not yet recruiting NCT06313294 - Postoperative Follow-up Via Text Messages Automated Versus Telephone in Patients With Continuous Regional Anesthesia N/A
Completed NCT02950558 - Anesthesia for Pain After Ankle Fracture Surgery Phase 4
Completed NCT05351151 - Pain Reduction in Maxillomandibular Surgery Using Maxillary and Mandibular Nerve Blocks N/A