Refractory Glaucoma Clinical Trial
Official title:
Comparison Between Two Techniques of Subthreshold Diode Laser Cyclophotocoagulation in Refractory Glaucoma
The aim of this study is to assess the results of subliminal subthreshold transscleral diode cyclophotocoagulation in refractory glaucoma using the standard technique of 360 degree application and to compare the outcome with a modified technique both in terms of efficacy and safety.
Refractory glaucoma is glaucoma that doesn't respond favorably to surgical and/or medical treatment to lower intraocular pressure. It can include primary open angle glaucoma, primary angle closure glaucoma, neovascular glaucoma or silicone oil-induced glaucoma. Cyclophotocoagulation (CPC) is a form of cycloablation using laser to treat glaucoma. It involves ciliary body destruction by targeting the ciliary epithelium and stroma, resulting in a reduction in aqueous secretion and hence intraocular pressure. Transscleral cyclophotocoagulation using a continuous diode laser has been a treatment option in advanced glaucoma cases with s¬¬uboptimal IOP control, for a long time. High treatment energy used by diode laser cyclophotocoagulation was argued to be associated with increased frequency of serious complications such as vision loss, hypotony, and phthisis. These concerns necessitate modulation of the parameters of laser treatment used. Micropulse transscleral cyclophotocoagulation (MP-TSCPC), which is a variation of conventional continuous-wave CPC, has emerged as an attractive alternative for the treatment of many types of glaucoma. It breaks the continuous wave laser into multiple short and repetitive pulses that allow the tissue to cool down between applications, thus reducing thermal damage. This strategy delivers very short energy pulses followed by rest periods, which is known as "duty cycle" and is defined as the ratio of time that a laser is delivering energy vs resting (ON/OFF). For this procedure, an infrared diode laser is used to stimulate the ciliary body structures and the uveoscleral pathway. This way it reduces the production of the aqueous humour and facilitates the uveoscleral outflow, with IOP reduction as a final effect. Despite promising results, only few clinical studies are published on MP-TSCPC and most of them are retrospective studies refer to patients having previous continuous wave transscleral cyclophotocoagulation. Moreover, Several parameters and protocols have been studied in other reports in an attempt to refine the standard technique aiming to improve the outcomes without increasing the adverse effects. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT01128699 -
Ahmed Valve Glaucoma Implant With Adjunctive Subconjunctival Bevacizumab in Refractory Glaucoma
|
Phase 3 | |
Completed |
NCT05521334 -
MicroPulse Transscleral Laser Cyclophotocoagulation With the Zig Zag Mode in Glaucoma.
|
N/A | |
Recruiting |
NCT00349414 -
Safety Study of Conventional Versus Micropulse Transscleral Cyclophotocoagulation in Treating End-Stage Glaucoma
|
Phase 1/Phase 2 | |
Recruiting |
NCT04921098 -
CPC in Adult Refractory Glaucoma
|
N/A | |
Completed |
NCT01404364 -
Use of Intravitreal Triamcinolone and Retrobulbar Chlorpromazine as Alternatives to the Management of Painful Blind Eye
|
N/A | |
Completed |
NCT00971061 -
Ahmed Glaucoma Valve and Single-Plate Molteno Implants in Treatment of Refractory Glaucoma
|
Phase 3 | |
Completed |
NCT04303897 -
Real-world Evidence Study of XEN in Chinese Patients With Refractory Glaucoma
|
||
Recruiting |
NCT00893490 -
Ahmed Glaucoma Valve Alone, With Amniotic Membrane or With Mitomycin C (MMC) for Treatment of Refractory Glaucoma
|
Phase 1 |