Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT01964261
Other study ID # HS-13-00492
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date November 1, 2013
Est. completion date January 31, 2027

Study information

Verified date May 2023
Source California Institute of Technology
Contact Charles Liu, MD, PhD
Phone 800-872-2273
Email chasliu@cheme.caltech.edu
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This research study is being conducted to develop a brain controlled medical device, called a brain-machine interface. The device will provide people with a spinal cord injury some ability to control an external device such as a computer cursor or robotic limb by using their thoughts along with sensory feedback. Development of a brain-machine interface is very difficult and currently only limited technology exists in this area of neuroscience. Other studies have shown that people with high spinal cord injury still have intact brain areas capable of planning movements and grasps, but are not able to execute the movement plans. The device in this study involves implanting very fine recording electrodes into areas of the brain that are known to create arm movement plans and provide hand grasping information and sense feeling in the hand and fingers. These movement and grasp plans would then normally be sent to other regions of the brain to execute the actual movements. By tying into those pathways and sending the movement plan signals to a computer instead, the investigators can translate the movement plans into actual movements by a computer cursor or robotic limb. A key part of this study is to electrically stimulate the brain by introducing a small amount of electrical current into the electrodes in the sensory area of the brain. This will result in the sensation of touch in the hand and/or fingers. This stimulation to the brain will occur when the robotic limb touches the object, thereby allowing the brain to "feel" what the robotic arm is touching. The device being used in this study is called the Neuroport Array and is surgically implanted in the brain. This device and the implantation procedure are experimental which means that it has not been approved by the Food and Drug Administration (FDA). One Neuroport Array consists of a small grid of electrodes that will be implanted in brain tissue and a small cable that runs from the electrode grid to a small hourglass-shaped pedestal. This pedestal is designed to be attached to the skull and protrude through the scalp to allow for connection with the computer equipment. The top portion of the pedestal has a protective cover that will be in place when the pedestal is not in use. The top of this pedestal and its protective cover will be visible on the outside of the head. Three Neuroport Arrays and pedestals will be implanted in this study so three of these protective covers will be visible outside of the head. It will be possible to cover these exposed portions of the device with a hat or scarf. The investigators hope to learn how safe and effective the Neuroport array plus stimulation is in controlling computer generated images and real world objects, such as a robotic arm, using imagined movements of the arms and hands.


Description:

The long-term objective of this application is to understand cortical processing of sensory to motor transformations within the human cerebral cortex. A vast number of computations must be performed to achieve sensory-guided motor control. Standing out among these computations, visual information of the goals of action must be transformed from the coordinates of the retina to the coordinates of effectors used for movement, for instance limb coordinates for reaching under visual guidance and to world coordinates for interactions in the environment. Once an object is grasped, somatosensory signals from the hand are required for dexterous manipulation of grasped objects. Internal models within the sensory motor pathway are essential for estimating the current state of the body and the external environment, accounting for lags in sensory feedback, and calibrating the body to the environment. We will use the rare opportunity of being able to record from populations of single neurons in a clinical study designed to develop neural prosthetics for tetraplegic participants paralyzed by spinal cord injuries. Cortical implants of microelectrode arrays will be made within three key locations in the sensorimotor system: primary motor cortex, primary somatosensory cortex, and posterior parietal cortex. These microelectrode arrays enable both recording and intracortical microstimulation. We will test the hypothesis that somatosensory and motor cortex represent imagined reaches in hand coordinates, but posterior parietal cortex is task dependent, and it's population neural activity can flexibly change coordinate frames depending on the effector used in the task. Percepts evoked by intracortical microstimulation and imagined sensations will be used to understand the representation of cutaneous and proprioceptive information within primary somatosensory cortex and posterior parietal cortex. The hypothesis to be tested is that imagined sensation and electrically evoked sensations are highly overlapping - not just in primary somatosensory cortex but also in posterior parietal cortex. Lastly, we hypothesize that the posterior parietal cortex contains in humans an internal model of state estimation that shows plasticity for both natural and brain-control behaviors and transfers this learning to motor cortex. These studies will not only greatly advance our understanding of the human sensorimotor cortical circuit, but also will provide basic knowledge for the design of future neural prosthetics.


Recruitment information / eligibility

Status Recruiting
Enrollment 5
Est. completion date January 31, 2027
Est. primary completion date July 31, 2026
Accepts healthy volunteers No
Gender All
Age group 22 Years to 65 Years
Eligibility Inclusion Criteria: - High cervical spinal lesion - Age 22-65 - Able to provide informed consent - Able to understand and comply with instructions in English - Communicate via speech - Surgical clearance - Life expectancy greater than 12 months - Travel up to 60 miles to study locations up to five days per week - Caregiver monitor for surgical site complications and behavioral changes on a daily basis - Psychosocial support system Exclusion Criteria: - Presence of memory problems - Intellectual impairment - Psychotic illness or chronic psychiatric disorder, including major depression if untreated - Poor visual acuity - Pregnancy - Active infection or unexplained fever - Scalp lesions or skin breakdown - HIV or AIDS infection - Active cancer or chemotherapy - Diabetes - Autonomic dysreflexia - History of seizure - Implanted hydrocephalus shunt - Previous neurosurgical history affecting parietal lobe function - Medical conditions contraindicating surgery and chronic implantation of a medical device - Prior cranioplasty - Unable to undergo MRI or anticipated need for MRI during study - Nursing an infant or unwilling to bottle-feed infant - Chronic oral or intravenous use of steroids or immunosuppressive therapy - Suicidal ideation - Drug or alcohol dependence - Planning to become pregnant, or unwilling to use adequate birth control - Implanted Cardiac Defibrillator, Pacemaker, vagal nerve stimulator, or spinal cord stimulator. - Implanted deep brain stimulator (DBS), DBS leads, or cochlear implant.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Neural Prosthetic System 2 (NPS2)
The NPS2 comprises 3 NeuroPort Arrays (SIROF). The tip of the electrodes are sputtered iridium oxide film (SIROF). Each array is comprised of 100 1.5 mm microelectrodes organized on a 4mm x 4mm silicon base that is 0.25 mm thick. Each microelectrode is insulated with Parylene-C polymer and is electrically isolated from neighboring electrodes by non-conducting glass. Of the 100 electrodes, 96 are wire bonded using 25m gold alloy insulated wires sealed with a silicone elastomer. The wire bundle is potted to a printed circuit board with epoxy, the circuit board is inserted into the Patient Pedestal (percutaneous connector), and then the Patient Pedestal is filled with silicone elastomer. Two fine platinum reference wires are also attached to the Patient Pedestal. The Patient Pedestal is 19 mm wide at the skin interface.

Locations

Country Name City State
United States University of Colorado Anschutz Medical Campus Aurora Colorado
United States Rancho Los Amigos National Rehabilitation Center Downey California
United States University of Southern California Los Angeles California
United States Richard Andersen Pasadena California

Sponsors (4)

Lead Sponsor Collaborator
Richard A. Andersen, PhD Rancho Los Amigos National Rehabilitation Center, University of Colorado - Anschutz Medical Campus, University of Southern California

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Patient control over the end effector (virtual or physical) The primary effectiveness objective of this study is to evaluate the effectiveness of the NPS2 in controlling virtual or physical end effectors. Signals from posterior parietal cortex will allow the subject to control the end effector with accuracy significantly greater than chance; the subject will be able to perceive and discriminate ICMS above the level of chance; and,incorporating stimulation will improve the subject's control over the end effector.
We will evaluate the effectiveness of the NPS2 primarily by calculating the accuracy of the subjects' control over the end effector with and without ICMS, and comparing these different accuracies to the chance level, and to each other. Each subject will serve as his or her own control.
One year after array implantation
Primary Absence of infection or irritation The primary objective of this study is to evaluate the safety of the NPS2. Implantation will not be associated with infection or irritation, and that the serious adverse event rate will not rise above 1%. We will evaluate the safety of the NPS2 by inspecting the subjects' scalps for evidence of reddening or discharge, by performing regularly scheduled neurologic history and physical exam, and by obtaining feedback from the subjects. The condition of the area will be compared with its condition on previous visits, history will be obtained regarding new symptoms and neurological and physical exam will be compared to baseline exams. One year after array implantation
See also
  Status Clinical Trial Phase
Completed NCT00385918 - Robotically Assisted Treadmill Training in Spinal Cord Injury (SCI) N/A
Completed NCT04306328 - Neural Stimulation for Hand Grasp N/A
Recruiting NCT05321017 - Wrist Extensor MEP Up-conditioning for Individuals With Incomplete Spinal Cord Injury N/A
Recruiting NCT01958086 - Visuomotor Prosthetic for Paralysis N/A
Terminated NCT01498991 - Spinal Cord Injury Leg Rehabilitation Phase 1/Phase 2
Terminated NCT04265560 - Progressive Resistance Training in Acute Spinal Cord Injury N/A
Completed NCT01124292 - Evaluation of a Tongue Operated Assistive Technology for Individuals With Severe Paralysis Phase 1
Completed NCT00270855 - Exercise to Reduce Obesity in Spinal Cord Injury N/A
Completed NCT00656149 - In-home Telerehabilitation for Quadriplegic Hand Function Phase 2/Phase 3
Active, not recruiting NCT00059553 - Retraining Walking After Spinal Cord Injury Phase 2/Phase 3
Terminated NCT00004415 - Study of Combined Intercostal and Diaphragm Pacing for Artificial Respiration in Quadriplegic Patients N/A
Completed NCT00632528 - MEOPA to Improve Physical Therapy Results After Multilevel Surgery Phase 3
Completed NCT01899664 - Upper Extremity Surgery in Spinal Cord Injury N/A
Completed NCT00221767 - Medico-economical Impact of the Brindley Neurosurgical Technique in France N/A
Completed NCT03482310 - Restoring High Dimensional Hand Function to Persons With Chronic High Tetraplegia N/A
Recruiting NCT06429735 - Precise Robotically IMplanted Brain-Computer InterfacE N/A
Completed NCT02354625 - The Safety of ahSC in Chronic SCI With Rehabilitation Phase 1
Completed NCT01911559 - Effectiveness of Standing Frame on Constipation in Children With Cerebral Palsy N/A
Completed NCT00010374 - Electrical Activation of The Diaphragm for Ventilatory Assist N/A
Withdrawn NCT02861612 - Nerve Transfers to Restore Hand Function in Spinal Cord Injury