Clinical Trials Logo

Clinical Trial Summary

In recent years, portable and ultra-portable ultrasound devices are increasingly used by the non radiologists, notably cardiologists or obstetrician gynecologist, at the patient's bedside to visualize and measure anatomical structures and fluid and provide the clinical examination with additional signs allowing quicker and more confident clinical decisions. This innovative approach is slowed down by the accessibility of these miniaturized devices, the price of which remains high. The echOpen device includes an ultra-portable ultrasound probe and a mobile application that allows the image to be displayed on a smartphone via a WIFI protocol. The objective of the clinical investigation is to show that the echOpen device, using three frequencies 3.5 Mhz, 5.0 Mhz and 7.5 Mhz, allows identifying the semiological signs or anatomical structures of interest located at several depths of the body, with a performance similar to other devices routinely used in clinical departments.


Clinical Trial Description

The echOpen device includes an ultrasound probe and a mobile application. The mechanical probe emits at three ultrasound frequencies, 3.5 Mhz, 5.0 Mhz and 7.5 Mhz, which allows the exploration of the interior of the body at different depths in a non-invasive and non-irradiating manner. Thus, the purpose of the echOpen device is, on one hand, to guide the diagnosis during the clinical examination and, on the other hand, to identify anatomical structures in order to assist in management. The objective of the clinical investigation is to demonstrate that the echOpen device is able to identify semiological signs and localize anatomical structures at different depths of the body, with a performance not inferior to that of other ultrasound devices, routinely employed in hospital clinical departments. The signs of interest (i.e. search for an intra-abdominal (3.5 Mhz) and pleural (5.0 Mhz) effusion) were chosen for their clinical usefulness (their presence during the clinical examination constitutes an argument for orientation and/or severity) and for their prevalence in the study population. The identification of anatomical structure of interest (i.e. detection of basilic vein (7.5Mhz)) was chosen because it is a gesture frequently used when taking in charge of a patient hospitalized in the selected departments. An ultrasound probe in use in the hospital clinical departments where the investigation takes place will be employed as a comparator to judge the performance of the echOpen device. This clinical investigation is part of a CE marking procedure. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05280119
Study type Interventional
Source Assistance Publique - Hôpitaux de Paris
Contact
Status Completed
Phase N/A
Start date April 4, 2022
Completion date August 19, 2022

See also
  Status Clinical Trial Phase
Completed NCT04159831 - A Study to Evaluate LTI-01 in Patients With Infected, Non-draining Pleural Effusions Phase 2
Recruiting NCT02891642 - Liquid Biopsy With Immunomagnetic Beads Capture Technique for Malignant Cell Detection in Body Fluid
Completed NCT02232841 - Electrical Impedance Imaging of Patients on Mechanical Ventilation N/A
Completed NCT02045641 - Pleural and Pericardial Effusion Following Open Heart Surgery N/A
Completed NCT01948076 - Evaluation of a Pocket-Sized Ultrasound Device As an Aid to the Physical Examination N/A
Completed NCT01416519 - Physiotherapy Technique Decreases Respiratory Complications After Cardiac Operation N/A
Completed NCT01560078 - Efficacy Study of Thrice Weekly Directly Observed Treatment Short-Course Regimen in Tubercular Pleural Effusion N/A
Completed NCT04891705 - Point of Care Ultrasound Lung Artificial Intelligence (AI) Validation Data Collection Study
Recruiting NCT05759117 - Prospective Evaluation of Patients With Pleural Effusion
Recruiting NCT05910112 - Prospective Data Collection on Clinical, Radiological and Patient Reported Outcomes After Pleural Intervention
Completed NCT03896672 - Clinical Implementation of the Use of Positive Pressure in Chest Drainage N/A
Active, not recruiting NCT06075836 - AI Assisted Detection of Chest X-Rays
Recruiting NCT03728491 - Education and Training Competences in Thoracic Ultrasound N/A
Not yet recruiting NCT03260088 - Evaluation Of Pleural Effusion At Assiut University Hospital N/A
Completed NCT03535883 - The Safety of Thoracentesis, Tunneled Pleural Catheter, and Chest Tubes in Patients Taking Novel Oral Anti-Coagulants
Completed NCT03296280 - Evaluation of Implementation of a National Point-of-Care Ultrasound Training Program
Completed NCT03661801 - Novel Pleural Fluid, Biopsy and Serum Biomarkers for the Investigation of Pleural Effusions
Completed NCT01778270 - Not Invasive Monitoring of Pleural Drainage N/A
Terminated NCT00402896 - Malignant Pleural Effusion With ZD6474 Phase 2
Recruiting NCT00103766 - Alteplase for Treatment of Empyema and Complicated Parapneumonic Effusion N/A