The purpose of this study is to evaluate the sensitivity and specificity of the Cardiox Flow Detection System (FDS) in identifying an intracardiac right-to-left shunt (RLS) compared to the results of transesophageal echocardiography (TEE).

RLS intracardiac shunts are associated with a number of clinically important syndromes including paradoxical thromboembolism (causing stroke or other systemic infarct), migraine headaches (particularly with aura), desaturation with obstructive sleep apnea, and decompression illness. From a research perspective, the detection of shunts in subjects with these types of syndromes is critical in helping to define the role of RLS in these disease processes. From a clinical perspective, shunt detection will be increasingly important in an era where interventional procedures for repairing cardiac defects are available for subjects determined to be at risk.

The currently accepted reference standard for detection of an intra-cardiac patent foramen ovale/atrial septal defect (PFO/ASD) RLS is a transesophageal echocardiography (TEE), a procedure that is invasive, uncomfortable, and requires conscious sedation.

Alternative options include transthoracic echocardiography (TTE) with injection of agitated saline (with and without Valsalva strain), a procedure that is far less sensitive than TEE due to the echocardiography imaging limitations seen in many adults.

Finally, transcranial Doppler (TCD) with injection of agitated saline (with and without Valsalva strain) is a newer entrant into this arena that does not require sedation or any invasive instrumentation.

The Cardiox Model 100 FDS utilizes an optical sensor positioned on the surface of the subject's skin at the scaphoid fossa of the ear. Next, a predetermined dose of an indicator dye, indocyanine green (ICG), is injected at a predetermined rate into a peripheral antecubital vein of the subject while the subject performs a breathing maneuver called a Valsalva maneuver. The exhalation by the subject into a mouthpiece connected to a pressure transducer via a flexible tubing extension, or its equivalent (ie, performing the Valsalva maneuver), is an essential step for all existing RLS detection methods. The Valsalva maneuver by the subject creates a pressure differential between the right and left sides of the heart. This Valsalva maneuver results in blood flow from the right side of the heart to the left side of the heart through an ASD, and/or causes a PFO, if present, to open, also allowing blood to flow directly from the right side to the left side of the heart without passing through the lungs (pulmonary vasculature) for oxygenation.

The Earpads, including their fluorescence sensor arrays (FSA), are used to measure the relative concentration (ie, fluorescence signal level) of ICG dye in the bloodstream as a function of time. If a premature inflection or peak occurs in the ICG dye concentration level at a time point prior to the rise and fall of the concentration associated with the main bolus of indicator, then a RLS is present in the heart. The amplitude of this premature ICG dye-dilution curve (referred to as "RLS-indicator dilution curve") is used to subsequently quantify the magnitude of the right-to-left shunt by ratiometrically comparing the amplitude of this RLS indicator dilution curve to the amplitude of the main indicator dilution curve associated with that portion of the injected ICG dye that follows the normal pathway from the right side of the heart, through the lungs, and into the left side of the heart (referred to as "normal indicator dilution curve").


Clinical Trial Description

n/a


Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic


Related Conditions & MeSH terms


NCT number NCT01773252
Study type Interventional
Source Cardiox Corporation
Contact
Status Terminated
Phase Phase 3
Start date November 2012
Completion date November 2015

See also
  Status Clinical Trial Phase
Completed NCT06192173 - Patent Foramen Ovale Closure in Migraine
Recruiting NCT04610463 - Evaluation of the Severity of Right to Left Shunt in PFO Patients After Systemic Embolism N/A
Completed NCT02882815 - Post Market Clinical Follow-up Study of IrisFITTM PFO (Patent Foramen Ovale) Occluder N/A
Completed NCT04604015 - RoBotic TCD Ultrasound BubbLe Study Compared to Transthoracic Echocardiography for Detection of Right to Left Shunt N/A
Active, not recruiting NCT04950192 - Philips Intracardiac Echocardiography (ICE) Clinical Registry
Not yet recruiting NCT04549272 - Assessment of Early Vascular Damage With Advanced Neuroimaging in Patient With Patent Foramen Ovale
Completed NCT02621528 - Lifetech CeraFlex™ Post-Market Surveillance Study N/A
Terminated NCT01018355 - The Effect of Device Closure of Patent Foramen Ovale in Elderly Patients With Crytogenic Stoke/TCI N/A
Completed NCT00831259 - Risk of Stroke in Pulmonary Embolism With a Patent Foramen Ovale (PFO) N/A
Not yet recruiting NCT05360771 - Study on the Safety and Effectiveness of the SnowyTM PFO Closure System N/A
Recruiting NCT05546320 - Comparison of the Effect of Medication Therapy in Alleviating Migraine With Patent Foramen Ovale Phase 4
Recruiting NCT05561660 - COMParison of the EffecT of dEvice Closure in Alleviating Migraine With PFO (COMPETE-2) Phase 4
Completed NCT03904277 - Does Patent Foramen Ovale Size Matter in Men and Women
Recruiting NCT06120270 - CeraFlex PFO Closure System PMCF Study
Completed NCT01216423 - Pulmonary Embolism and Stroke in Patient With Patent Foramen Ovale N/A
Completed NCT03377465 - Biomarkers, Hemodynamic and Echocardiographic Predictors of Ischemic Strokes and Their Influence on the Course and Prognosis N/A
Active, not recruiting NCT04738071 - International Multicenter Patent foRamen OVale & strokE (IMPROVE) Registry
Not yet recruiting NCT06344494 - Cardiac Interventional ICE Imaging Trial N/A
Withdrawn NCT02378623 - Patients With Patent Foramen Ovale and Endocardial Device Leads on Apixaban for Prevention of Paradoxical Emboli Phase 2
Completed NCT01854281 - Nitrogen Bubble Detection After Simulated Dives in Divers With PFO and After PFO Closure N/A