Clinical Trials Logo

Clinical Trial Summary

This study aims to investigate the effect of reducing ablation time for a hybrid approach of vHPSD and AI-guided ablation using the QDOT Micro catheter in PVI among patients with PAF.


Clinical Trial Description

Radiofrequency catheter ablation has become a cornerstone strategy for the rhythm control of AF. During the last decade, catheter technology has revolutionized and, accordingly, clinical outcomes after the ablation and procedural efficacy have been improved. In recent years, the use of the CLOSE protocol employing contiguous, closely spaced applications and targeted ablation index (AI) values has translated into robust acute and long-term success rates for PVI, typically with the power delivery of up to 35 W, and more recently with 40 to 50 W, in power and temperature-controlled mode. Contiguous ablation using very high-power, short-duration ablation at 90 W over 4 seconds is expected to shorten procedure time. However, changes in lesion geometry and the altered impact of catheter stability on lesion quality may influence procedural efficiency, safety, and effectiveness. The Q-FFICIENCY trial showed that the vHPSD (90 W, 4 sec), temperature-controlled radiofrequency ablation (25/50 W) has comparable efficacy to conventional-power temperature-controlled ablation. However, the efficacy of vHPSD ablation may depend on PV thickness due to its lesion characteristics. Therefore, AI-guided ablation may have merits over vHPSD ablation in thickened PV segments. According to the POWER PLUS trial, the proportion of 1st-pass PVI with vHPSD ablation was numerically lower than that of the conventional ablation, although there was marginal significance; 83.9% vs. 90.0%, p-value =0.085. According to the OPTIMUM trial, a study conducted by our group, roof and anterior walls of the left atrium often require higher AI targets due to their thickness. Therefore, a hybrid approach that combines both vHPSD and AI-guided ablations according to PV segments may achieve both high efficacy and short ablation time for PVI. The investigators of the POWER PLUS trial also speculated that the hybrid approach based on tissue thickness might offer the optimal balance of procedural efficacy. However, up to date, no studies have investigated the efficacy and safety of the hybrid approach for PVI. More data is needed to suggest that the hybrid approach could be useful for PVI. Therefore, this study aims to investigate the effect of reducing ablation time for a hybrid approach of vHPSD and AI-guided ablation using the QDOT Micro catheter in PVI among patients with PAF. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05996159
Study type Interventional
Source Seoul National University Hospital
Contact
Status Not yet recruiting
Phase N/A
Start date October 1, 2023
Completion date September 30, 2026

See also
  Status Clinical Trial Phase
Completed NCT05970120 - A Study of Intracardiac Ultrasound With the NUVISION NAV Ultrasound Catheter N/A
Recruiting NCT06014996 - Comparison of PFA vs. RFA in Patients With Symptomatic Paroxysmal Atrial Fibrillation. N/A
Completed NCT03624881 - Evaluation of VISITAG SURPOINT™ Module With External Processing Unit (EPU) Phase 4
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Recruiting NCT05905835 - Treatment of PAF With the Synaptic System N/A
Active, not recruiting NCT05534581 - SINGLE SHOT CHAMPION Phase 4
Active, not recruiting NCT05618340 - PFA for Paroxysmal Atrial Fibrillation N/A
Not yet recruiting NCT05024630 - Renal Denervation and pUlmonary Vein isolAtion With cryoabLation on Patients With Atrial Fibrillation and hypErtension N/A
Completed NCT02610803 - Paroxysmal Atrial Fibrillation in Patients With Acute Ischemic Stroke N/A
Completed NCT01913522 - Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation: Double Short vs. Standard Exposure Duration N/A
Terminated NCT01925885 - Focal Impulse and Rotor Modulation Ablation Trial for Treatment of Paroxysmal Atrial Fibrillation (FIRMAT-PAF) N/A
Withdrawn NCT01917981 - Testing the Accuracy of a Personal Heart Rhythm Monitor to Detect Prolonged Paroxysmal Atrial Fibrillation Phase 3
Completed NCT01842529 - Botulinum Toxin Injection in Epicardial Fat Pads To Treat Atrial Fibrillation After Cardiac Surgery Phase 2
Completed NCT01693107 - Atrial Fibrillation Force Contact Ablation Study
Completed NCT00971204 - Clinical Study of the CardioFocus Endoscopic Ablation System - Adaptive Contact (EAS-AC) for the Treatment of Symptomatic Atrial Fibrillation Phase 2
Completed NCT05043883 - Automated Assessment of PVI Using a Novel EP Recording System N/A
Recruiting NCT05172765 - Biomarker-Guided Optimization of Transcutaneous Vagal Stimulation for Atrial (BiG tVNS-AF) N/A
Recruiting NCT04529785 - Added Value of Vein of Marshal Ethanol Infusion Compared to Superior Vena Cava Isolation Alone in Patients Undergoing Repeat Ablation for Recurrent Paroxysmal Atrial Fibrillation Despite Durable PV Isolation N/A
Completed NCT04022954 - HD Mapping of Atrial Fibrillation in Asia Pacific
Completed NCT00964392 - NAVISTAR® THERMOCOOL® Catheter Post Approval Registry Phase 4