Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04022954
Other study ID # CRD975
Secondary ID
Status Completed
Phase
First received
Last updated
Start date September 11, 2019
Est. completion date August 13, 2021

Study information

Verified date October 2023
Source Abbott Medical Devices
Contact n/a
Is FDA regulated No
Health authority
Study type Observational [Patient Registry]

Clinical Trial Summary

The aim of this study is to quantify and characterize the outcomes of radiofrequency (RF) ablation after, and the utility of, electroanatomical mapping with the market-released HD mapping catheters Inquiry™ AFocusII™ Double Loop and Advisor™ HD Grid, Sensor Enabled™ with the EnSite Cardiac Mapping System and the EnSite Automap module in subjects with AF in the real-world environment of the Asian population.


Recruitment information / eligibility

Status Completed
Enrollment 200
Est. completion date August 13, 2021
Est. primary completion date August 13, 2021
Accepts healthy volunteers No
Gender All
Age group 18 Years to 99 Years
Eligibility Inclusion Criteria: 1. Subject must provide written informed consent for study participation and willing and able to comply with the protocol described evaluations and follow up schedule 2. Subject must be over 18 years of age. (In Japan, the subject must be of 20 years of age or older) 3. Subject is diagnosed with AF as defined by: - Documented symptomatic paroxysmal AF defined as AF that terminates spontaneously or with intervention within 7 days of onset - Documented symptomatic persistent AF defined as continuous atrial fibrillation that is sustained beyond 7 days but less than 12 months 4. Subject is indicated for cardiac electroanatomical mapping and RF ablation procedure to treat AF 5. Subject is planned to have electroanatomical mapping performed with the HD mapping catheters under investigation Exclusion Criteria: 1. Previous ablation or surgery in the left atria 2. Implanted left atrial appendage occluder 3. Implanted mitral or tricuspid valve replacement 4. Implanted cardiac defibrillator (ICD) 5. Participation in another clinical investigation that may confound the results of this study 6. Pregnant or nursing 7. Presence of other anatomic or comorbid conditions, or other medical, social, or psychological conditions that, in the investigator's opinion, could limit the subject's ability to participate in the clinical investigation or to comply with follow-up requirements, or impact the scientific soundness of the clinical investigation results. 8. Life expectancy less than 12 months

Study Design


Intervention

Device:
Catheter ablation
Inquiry AFocusII Double Loop and Advisor HD Grid, Sensor Enabled

Locations

Country Name City State
China Sir Run Run Shaw Hospital Hangzhou
China The Second Affiliated Hospital of Xian Jiaotong University Xi'an
Hong Kong Prince of Wales Hospital Hong Kong
Japan Yokosuka Kyosai Hospital Kanagawa
Japan Kokura Memorial Hospital Kitakyushu-shi Fukuoka
Japan Kyoto University Hospital Kyoto
Japan Ogaki Municipal Hospital Ogaki
Japan Saga University Hospital Saga
Japan Kitasato University Hospital Sagamihara
Japan Kyorin University Hospital Tama
Japan University of Tsukuba Hospital Tsukuba Ibaraki
Korea, Republic of Korea University Anam Hospital Seoul
Korea, Republic of Severance Hospital Seoul
Taiwan Kaohsiung Chang Gung Memorial Hospital Kaohsiung City
Taiwan Taipei Veterans General Hospital (VGH) Taipei City

Sponsors (1)

Lead Sponsor Collaborator
Abbott Medical Devices

Countries where clinical trial is conducted

China,  Hong Kong,  Japan,  Korea, Republic of,  Taiwan, 

Outcome

Type Measure Description Time frame Safety issue
Other Number of Participants With Adverse Events Adverse events include any device-, procedure-, or death-related events through study completion, an average of 1 year
Other Number of Subjects With Repeat Ablations Rate of repeat ablations was defined as proportion of subjects with an additional ablation procedure to treat indicated cardiac arrhythmia (outside blanking period, if applicable). This measure is presented here as the number of participants, and the associated percentage of subjects (proportion * 100%) is also displayed as the result of an automatic calculation. 12-months post-procedure
Other Change in Quality of Life (QoL): EQ-5D-5L VAS Score Defined as change in quality of life score assessed by the validated QoL survey, EQ-5D-5L. The EQ-5D-5L is a descriptive system comprised of five questions related to mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each question has 5 levels: no problems, slight problems, moderate problems, severe problems and extreme problems. The patient is asked to indicate his/her health state by ticking the box next to the most appropriate statement in each of the five dimensions. This decision results in a 1-digit number that expresses the level selected for that dimension. The digits for the five dimensions can be combined into a 5-digit number that describes the patient's health state.
EQ-5D-5L EQ VAS scores range from 0 (worst) to 100 (best). A positive change indicates an improvement.
12-months post-procedure
Primary Number of Participants With Acute Success of RF Ablation After Electroanatomical Mapping With HD Mapping Catheters. The rate of acute success was defined as the proportion of subjects who receive HD mapping and RF energy delivery resulting in acute termination of clinical arrhythmia, defined by termination to SR (or AT if being treated for PersAF) or non-inducibility of clinical arrhythmia after ablation (cardioversion allowed prior to inducibility attempt). This measure is presented here as the number of participants with acute success, and the associated percentage of subjects (proportion * 100%) with acute success is also displayed as the result of an automatic calculation. End of Procedure
Primary Number of Participants With Clinical Long-Term Success Freedom from all atrial arrhythmias (AF/AFL/AT) greater than 30 seconds (as documented by 24-hr Holter at 12-month follow-up) and on or off class I/III AADs. This measure is presented here as the number of participants, and the associated percentage of subjects (proportion * 100%) is also displayed as the result of an automatic calculation. 12 months post-procedure
Primary Number of Participants With AAD-Free Long-Term Success Freedom from all atrial arrhythmias (AF/AFL/AT) greater than 30 seconds (as documented by 24-hr Holter at 12-month follow-up) and off all class I/III AADs. This measure is presented here as the number of participants, and the associated percentage of subjects (proportion * 100%) is also displayed as the result of an automatic calculation. 12-month post-procedure
Secondary Overall Procedure Time Defined as time from initial catheter insertion to final catheter removal. This is one measure of the amount of time it took for the physician to use invasive tools (catheters) during the procedure to investigate, diagnose, and treat the participant's heart condition. During Procedure
Secondary Radiofrequency (RF) Time Defined as duration of time radiofrequency energy is delivered. This is a measure the amount of time the physician was actively applying treatment to the heart to treat the participant's heart condition. During Procedure
Secondary Fluoroscopy Time Defined as total time subject is exposed to fluoroscopy. Fluoroscopy is a type of medical imaging that uses x-rays. This imaging is used by the physician to facilitate a safe and effective procedure. Less fluoroscopy time may help reduce the risk of issues related to x-ray exposure, however other factors such as fluroscopy intensity (not measured in this study) may also be important. During Procedure
Secondary Mapping Time Associated With Mapping Arrhythmia Defined as the total cumulative mapping time and mapping time for the creation of each map (including any new or retrospective map created with Manual, AutoMap, and TurboMap mapping). As part of an ablation procedure to treat atrial fibrillation, some physicians create a map of the heart's electrical activity. The information in the map may be used by the physician to plan the treatment strategy. Mapping time provides a measure of how much time the physician spent creating, updating, and analyzing maps during the procedure. A short mapping time is not necessarily better or worse than a long mapping time, as other factors such as the amount and type of information gathered may also affect how useful the map is to the physician. During Procedure
Secondary Number of Mapping Points Collected Defined as total number of mapping points collected for the creation of each map. As part of an ablation procedure to treat atrial fibrillation, some physicians create a map of the heart's electrical activity. The information in the map may be used by the physician to plan the treatment strategy. Number of mapping points collected is a measure of how much information was collected. A small number of mapping points collected is not necessarily better or worse than a large number of points, as other factors such as the amount of time spent and type of information gathered may also affect how useful the map is to the physician. During Procedure
Secondary Number of Mapping Points Used Defined as the total number of mapping points used in each map. As part of an ablation procedure to treat atrial fibrillation, some physicians create a map of the heart's electrical activity. The information in the map may be used by the physician to plan the treatment strategy. Number of mapping points collected is a measure of how much information was collected, while number of mapping points used is a measure of how many such points were considered useful. A small number of mapping points used is not necessarily better or worse than a large number of points, as other factors such as the amount of time spent and type of information gathered may also affect how useful the map is to the physician. During Procedure
Secondary Number of Used Mapping Points Per Minute Defined as the total number of mapping points used divided by the relative mapping time. As part of an ablation procedure to treat atrial fibrillation, some physicians create a map of the heart's electrical activity. The information in the map may be used by the physician to plan the treatment strategy. Mapping time is a measure of how much time the physician spent collecting, updating, and analyzing the information in the map. Number of mapping points collected is a measure of how much information was collected, while number of mapping points used is a measure of how many such points were considered useful. The number of used mapping points per minute is a measure of how efficient the mapping process is. A larger number of used mapping points per minute may be associated with a more efficient mapping process. Mapping efficiency may be of interest to a physician, however other factors such as the type of information gathered may also be of interest. During Procedure
Secondary Substrate Characteristics Identified For each type of arrhythmogenic substrate this will be defined as the frequency of substrate type identified in cases that attempted to identify the specific substrate. As part of an ablation procedure to treat atrial fibrillation, some physicians create a map of the heart's electrical activity or use other tests to characterize the state, function, or health of certain areas of the heart tissue, and to localize certain areas that may be problematic (substrate). These localized characteristics may provide information to the physician that could be used to treat the participant's heart condition. This outcome measure lists common substrate characteristics and the number of subjects for which the characteristic was found or otherwise used as part of the treatment plan. During Procedure
Secondary Ablation Strategy(s) Used Defined by both the type of map used to define ablation strategy and the frequency each ablation strategy/target was used by physicians. A physician may use one or more strategies to treat the participant's heart condition, including selectively burning (ablating) certain areas of the heart. This outcome measure lists common ablation strategies and the number of participants that received treatment based on each strategy. During Procedure
See also
  Status Clinical Trial Phase
Completed NCT05970120 - A Study of Intracardiac Ultrasound With the NUVISION NAV Ultrasound Catheter N/A
Recruiting NCT06014996 - Comparison of PFA vs. RFA in Patients With Symptomatic Paroxysmal Atrial Fibrillation. N/A
Completed NCT03624881 - Evaluation of VISITAG SURPOINT™ Module With External Processing Unit (EPU) Phase 4
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Recruiting NCT05905835 - Treatment of PAF With the Synaptic System N/A
Active, not recruiting NCT05534581 - SINGLE SHOT CHAMPION Phase 4
Active, not recruiting NCT05618340 - PFA for Paroxysmal Atrial Fibrillation N/A
Not yet recruiting NCT05024630 - Renal Denervation and pUlmonary Vein isolAtion With cryoabLation on Patients With Atrial Fibrillation and hypErtension N/A
Completed NCT02610803 - Paroxysmal Atrial Fibrillation in Patients With Acute Ischemic Stroke N/A
Completed NCT01913522 - Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation: Double Short vs. Standard Exposure Duration N/A
Withdrawn NCT01917981 - Testing the Accuracy of a Personal Heart Rhythm Monitor to Detect Prolonged Paroxysmal Atrial Fibrillation Phase 3
Terminated NCT01925885 - Focal Impulse and Rotor Modulation Ablation Trial for Treatment of Paroxysmal Atrial Fibrillation (FIRMAT-PAF) N/A
Completed NCT01693107 - Atrial Fibrillation Force Contact Ablation Study
Completed NCT01842529 - Botulinum Toxin Injection in Epicardial Fat Pads To Treat Atrial Fibrillation After Cardiac Surgery Phase 2
Completed NCT00971204 - Clinical Study of the CardioFocus Endoscopic Ablation System - Adaptive Contact (EAS-AC) for the Treatment of Symptomatic Atrial Fibrillation Phase 2
Completed NCT05043883 - Automated Assessment of PVI Using a Novel EP Recording System N/A
Recruiting NCT05172765 - Biomarker-Guided Optimization of Transcutaneous Vagal Stimulation for Atrial (BiG tVNS-AF) N/A
Recruiting NCT04529785 - Added Value of Vein of Marshal Ethanol Infusion Compared to Superior Vena Cava Isolation Alone in Patients Undergoing Repeat Ablation for Recurrent Paroxysmal Atrial Fibrillation Despite Durable PV Isolation N/A
Completed NCT00964392 - NAVISTAR® THERMOCOOL® Catheter Post Approval Registry Phase 4
Recruiting NCT03912324 - Computed Tomogram Myocardial Thickness Map Guided pulmOnary Vein iSolaTion vs. Empirical Pulmonary Vein Isolation in Cryoballoon Ablation for Paroxysmal Atrial Fibrillation (UTMOST AF II) N/A