Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT06337435
Other study ID # 8223
Secondary ID
Status Completed
Phase
First received
Last updated
Start date December 15, 2022
Est. completion date January 18, 2024

Study information

Verified date March 2024
Source Cairo University
Contact n/a
Is FDA regulated No
Health authority
Study type Observational [Patient Registry]

Clinical Trial Summary

this study aim to evaluate the multi-looped lingual retainer activated by a new method to relief the anterior crowding


Description:

1. patients preparation( photo- impression- x-ray- scan the lower cast to calculate the crowding ) 2. The multi-looped lingual retainer was fabricated on the patient's lower cast 3. The lingual surfaces of teeth were etched with 35% phosphoric acid for 20 seconds The multi-looped lingual retainer was activated in the new way (Kattan method ) by tightening a steel ligature wire 0.010 inches, to the reinforcement 0.020-inch stainless steel arch-wire. 4. the bonding agent was applied on such surfaces after a good isolation and was light-cured for 20 seconds. 5. A flowable composite resin was applied. After checking its fit on the surface of the teeth, The lingual wire was bonded with a drop of flowable composite resin and was light-cured for 20 seconds. 6. follow-up the patients * Outcomes: The improvement of lower incisors irregularity using Little Irregularity Index.


Recruitment information / eligibility

Status Completed
Enrollment 12
Est. completion date January 18, 2024
Est. primary completion date July 10, 2023
Accepts healthy volunteers No
Gender All
Age group 16 Years to 25 Years
Eligibility Inclusion Criteria: - Adult male and female patients, the ages of 16 to 25, the patients having class I canine with mild to moderate lower incisors crowding - good oral hygiene. Exclusion Criteria: - Facial trauma, Oral habits such as onychophagia, pen biting, and tooth mobility.

Study Design


Related Conditions & MeSH terms

  • Crowding of Anterior Mandibular Teeth

Intervention

Other:
multi-looped wire
using multi-looped wire as a retainer

Locations

Country Name City State
Egypt faculty of dentistry Cairo university Cairo

Sponsors (1)

Lead Sponsor Collaborator
Cairo University

Country where clinical trial is conducted

Egypt, 

Outcome

Type Measure Description Time frame Safety issue
Primary The improvement of lower incisors irregularity using Little Irregularity Index. using multi-looped for relief crowding, the digital model analysis will be used to calculate the amount of irregularity by using Little Irregularity Index .the measurement will be done on 3-shape software. follow-up three to six months
Secondary The stability of lower incisor positioning after ending treatment using multi-looped as a retainer for stability to prevent the relapse after end treatment and the amount of lower incisor irregularity will be evaluated on scanned post-treatment digital models and measured on the 3-shape software. after 1-3 months
See also
  Status Clinical Trial Phase
Enrolling by invitation NCT05676840 - Comparing the Alignment Efficiency of Three Types of Nickel-titanium Archwires N/A
Recruiting NCT04815200 - Efficiency of Using Copper-Nickel-Titanium Versus Nickel-Titanium Arch Wires on Anterior Segment Crowding Alleviation in Group of Adults With Moderate Crowding N/A
Completed NCT04601662 - Evaluation of the Root Resorption and Dehiscence Formation Between Two Methods of Leveling and Alignment of Lower Teeth N/A
Completed NCT06401369 - Comparing Labial and Lingual Orthodontic Appliances on Root Resorption and Bone Height N/A
Completed NCT06401382 - Oral Health-Related Quality of Life Between Two Different Types of Orthodontic Appliances N/A
Recruiting NCT04940351 - Evaluation of the Effectiveness of Piezocision and Micro-osteoperforation in Alleviating Mandibular Anterior Crowding N/A
Recruiting NCT05492773 - Evaluating the Efficacy of Micro-Osteoperforations Technique on the Orthodontic Tooth Movement Acceleration in Moderate Mandibular Anterior Crowding Cases Treated With Clear Aligners N/A
Recruiting NCT03256279 - Mechanical Properties and Clinical Efficacy of Two Nickel-Titanium (NiTi) Archwires N/A
Completed NCT04988373 - Evaluation of the Efficiency of Single Aligner Appliance for Treatment of Mild Crowding Cases in Adults. N/A
Completed NCT04728464 - Pain, Acceptance, and Discomfort With Periodontally Accelerated Osteogenic Orthodontics (PAOO)
Completed NCT05510206 - SmartArch vs Super Elastic NiTi Aligning Archwires N/A