Transcatheter Aortic Valve Replacement Clinical Trial
Official title:
A Continuous ECG Monitoring Data Collection Study in Patients Undergoing Transcatheter Aortic Valve Replacement (TAVR) to Evaluate the Performance of the Cara Monitor Conduction Disturbance Risk Score (CDRS).
Prospective, non-randomized, multicenter data collection study. Eligible TAVR patients will be enrolled in the study. Cardiac conduction disturbances (CD) requiring permanent pacemaker implantation (PPM) or causing new-onset CD are frequent complications of TAVR that have been shown to be associated with increased mortality and re-hospitalization rates. The purpose of the study is to collect continuous ECG data in order to validate the performance of the Cara Conduction Disturbance Risk Score (CDRS) in patients undergoing transcatheter aortic valve replacement (TAVR). Subjects will be studied during the TAVR procedure and their ECG recordings according to the study schedule below of pre-, during, and after the TAVR procedure up to 14/30 days FU will be collected. 600 patients will be enrolled in this study with the hypothesis that Cara can deliver a statistically significant conduction disturbance risk stratification for patients undergoing TAVR. No investigation intervention is planned during this study. The Cara System analysis will be performed offline.
TAVR will be performed using site investigators' best practices including the use of standard-of-care catheters, devices, imaging, and monitoring modalities. Data will be collected to include the following patients' measures during this study: 1. Pre-procedure 1. Demographics 2. Medical history 3. Cardiac CT 4. 12 lead ECG 2. Procedure 1. Continuous 3-12 lead Holter will be supplied, data will be collected and analyzed by the study sponsor 2. Fluoroscopy (captured automatically by video system ) 3. Device manufacturer (type) and size 3. Post-procedure (in hospital) a. Continuous 1-3 lead Holter for 14 days will be supplied, and the data from the Holter recordings will be collected from the patient's home and analyzed. 4. Post-procedure (discharge) a. 12 lead ECG 5. Patients will be followed according to the current medical practice. Data to be collected during the FU : a. 12 lead ECG at 14/30 days The data collected from the study will be used to evaluate the performance Cara System, a conduction disturbance monitor that provides an indication of conduction disturbances during TAVR procedures. Conduction Disturbances (CD) outcome will be subdivided into: 1. PPM or High-Grade AV Block (HGAVB) 2. All other new onsets (or deterioration) of CD that are not listed in #1 3. No new onset CD ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05465655 -
Cara CDRM (Conduction Disturbance Risk Monitor) 2.0
|
N/A | |
Recruiting |
NCT04870424 -
Colchicine for Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement
|
Phase 3 | |
Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
Recruiting |
NCT05758701 -
CT TAVR Abdomen Study
|
Phase 4 | |
Active, not recruiting |
NCT04281771 -
Assessment of Paravalvular Leak After TAVI by Hemodynamic Measurements and Cardiac MRI
|
N/A | |
Enrolling by invitation |
NCT06212050 -
Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
|
||
Recruiting |
NCT04573049 -
The Effectiveness and Safety of Levosimendan in Patients With Severe Aortic Stenosis and Heart Failure Undergoing Transcatheter Aortic Valve Replacement
|
Phase 4 | |
Recruiting |
NCT05235555 -
EffecTAVI Registry
|
||
Completed |
NCT05082337 -
The SAVVY Guidewire in Transcatheter Aortic Valve Replacement Procedures
|
N/A | |
Completed |
NCT01627691 -
REPRISE II: REpositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus™ Valve System
|
N/A | |
Recruiting |
NCT05075590 -
Coronary Access After Supra-Annular THV Implantation
|
N/A | |
Completed |
NCT01651780 -
Open-label, Randomized Trial in Patients Undergoing TAVR to Determine Safety & Efficacy of Bivalirudin vs UFH
|
Phase 3 | |
Recruiting |
NCT05259241 -
ADAPT Transcatheter Aortic Valve Intervention (TAVI & Chronic Total Occlusion Percutaneous Coronary Intervention (CTO PCI)
|
N/A | |
Completed |
NCT04489914 -
Observational Study on the Application of High-Flow Therapy After Percutaneous Transfemoral Aortic Valve Replacement
|
||
Recruiting |
NCT03649594 -
Risk Stratification Post TAVI Using TEG
|
||
Completed |
NCT04659538 -
The CAPTIS® Study - Embolic Protection in TAVR
|
N/A | |
Recruiting |
NCT04107038 -
Monitored Anesthesia Care vs. General Anesthesia for Transcatheter Aortic Valve Replacement
|
N/A | |
Withdrawn |
NCT04268160 -
GPx Activity in Subjects With Aortic Stenosis Undergoing TAVR
|
||
Recruiting |
NCT02812953 -
Biological Collection and Registry of Patients Who Will Have a TAVR (Transcatheter Aortic Valve Replacement) Intervention
|
||
Recruiting |
NCT05217888 -
The Sentinel Registry
|