Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03608332
Other study ID # DUS in weaning
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date April 30, 2018
Est. completion date September 29, 2019

Study information

Verified date September 2019
Source Cairo University
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

To assess value of adding ultrasound derived variables to the usual parameters on success rate of weaning from mechanical ventilation in critically ill patients and to validate sensitivity and specificity of ultrasound derived variables (thickening fraction /diaphragmatic excursion)


Description:

Difficult weaning from mechanical ventilation (MV) is a common problem in critically ill patients. Many parameters have been developed to aid weaning from MV such as P/F ratio (PO2/FiO2) and rapid shallow breathing index (respiratory rate/tidal volume), however, sensitivity and specificity for most variables are still variable in literature.

Multiple studies have found that patients tolerantof SBTs were found to have successful discontinuationsat least 77% of the time.

Causes of weaning failure include: airway and lung dysfunction, brain dysfunction, cardiac dysfunction, diaphragm dysfunction, and endocrine dysfunction .

Diaphragmatic dysfunction is a common cause of weaning failure , however most of the traditional methods used for evaluation of diaphragmatic function (fluoroscopy, trans-diaphragmatic pressure measurement) are invasive and not available.

Ultrasound assessment of diaphragmatic function has been developed recently providing an easy and safe method for evaluation of diaphragmatic excursion and thickening.

It was found that weaning failure (Re-intubation within 48 hours) was associated with diaphragmatic excursion <1 cm and thickening fraction <28% several studies reported the value of diaphragmatic ultrasound to predict weaning failure ,however no one of them used diaphragmatic ultrasound to guide weaning.

previous studies showed that failure rate of weaning from mechanical ventilation was 27% ,however failure rate in our department was 43% adding ultrasound derived values aims for improving success rate of weaning from mechanical ventilation.


Recruitment information / eligibility

Status Completed
Enrollment 160
Est. completion date September 29, 2019
Est. primary completion date September 29, 2019
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

- Critically ill patients intubated for more than 48 hours who are ready for weaning

Exclusion Criteria:

- • Age < 18 years

- surgical dressings over the right lower rib cage which would preclude ultrasound examination

- patients with chest trauma, thoracotomy, diaphragmatic paralysis, diaphragmatic injury and diaphragmatic surgery

- patients with neuromuscular diseases ( myasthenia gravis ,Muscular dystrophies ,Multiple sclerosis and Amyotrophic lateral sclerosis)

Study Design


Related Conditions & MeSH terms

  • Diaphragmatic Ultrasound in Weaning

Intervention

Device:
diaphragmatic ultrasound
Diaphragmatic excursion; Diaphragmatic movement will be measured with a 3.5-MHz US probe (Mindray machine, DC-N6).

Locations

Country Name City State
Egypt Cairo University-Manial Cairo

Sponsors (1)

Lead Sponsor Collaborator
Cairo University

Country where clinical trial is conducted

Egypt, 

References & Publications (11)

DiNino E, Gartman EJ, Sethi JM, McCool FD. Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation. Thorax. 2014 May;69(5):423-7. doi: 10.1136/thoraxjnl-2013-204111. Epub 2013 Dec 23. — View Citation

El-Khatib MF, Bou-Khalil P. Clinical review: liberation from mechanical ventilation. Crit Care. 2008;12(4):221. doi: 10.1186/cc6959. Epub 2008 Aug 6. Review. — View Citation

Esteban A, Alía I, Tobin MJ, Gil A, Gordo F, Vallverdú I, Blanch L, Bonet A, Vázquez A, de Pablo R, Torres A, de La Cal MA, Macías S. Effect of spontaneous breathing trial duration on outcome of attempts to discontinue mechanical ventilation. Spanish Lung Failure Collaborative Group. Am J Respir Crit Care Med. 1999 Feb;159(2):512-8. — View Citation

Esteban A, Frutos F, Tobin MJ, Alía I, Solsona JF, Valverdú I, Fernández R, de la Cal MA, Benito S, Tomás R, et al. A comparison of four methods of weaning patients from mechanical ventilation. Spanish Lung Failure Collaborative Group. N Engl J Med. 1995 Feb 9;332(6):345-50. — View Citation

Fagon JY, Chastre J, Hance AJ, Montravers P, Novara A, Gibert C. Nosocomial pneumonia in ventilated patients: a cohort study evaluating attributable mortality and hospital stay. Am J Med. 1993 Mar;94(3):281-8. — View Citation

Ferrari G, De Filippi G, Elia F, Panero F, Volpicelli G, Aprà F. Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation. Crit Ultrasound J. 2014 Jun 7;6(1):8. doi: 10.1186/2036-7902-6-8. eCollection 2014. — View Citation

Heunks LM, van der Hoeven JG. Clinical review: the ABC of weaning failure--a structured approach. Crit Care. 2010;14(6):245. doi: 10.1186/cc9296. Epub 2010 Dec 8. Review. — View Citation

Jiang JR, Tsai TH, Jerng JS, Yu CJ, Wu HD, Yang PC. Ultrasonographic evaluation of liver/spleen movements and extubation outcome. Chest. 2004 Jul;126(1):179-85. — View Citation

Kim WY, Suh HJ, Hong SB, Koh Y, Lim CM. Diaphragm dysfunction assessed by ultrasonography: influence on weaning from mechanical ventilation. Crit Care Med. 2011 Dec;39(12):2627-30. doi: 10.1097/CCM.0b013e3182266408. — View Citation

MacIntyre NR, Cook DJ, Ely EW Jr, Epstein SK, Fink JB, Heffner JE, Hess D, Hubmayer RD, Scheinhorn DJ; American College of Chest Physicians; American Association for Respiratory Care; American College of Critical Care Medicine. Evidence-based guidelines for weaning and discontinuing ventilatory support: a collective task force facilitated by the American College of Chest Physicians; the American Association for Respiratory Care; and the American College of Critical Care Medicine. Chest. 2001 Dec;120(6 Suppl):375S-95S. Review. — View Citation

Matamis D, Soilemezi E, Tsagourias M, Akoumianaki E, Dimassi S, Boroli F, Richard JC, Brochard L. Sonographic evaluation of the diaphragm in critically ill patients. Technique and clinical applications. Intensive Care Med. 2013 May;39(5):801-10. doi: 10.1007/s00134-013-2823-1. Epub 2013 Jan 24. Review. — View Citation

* Note: There are 11 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Success rate of weaning from mechanical ventilation in both groups (The trial will be considered a successful weaning trial if the patient passed 48 hours without the need for neither invasive nor non-invasive ventilation) 48 Hours after weaning
Secondary • Rapid shallow breathing index (RSBI) and its correlation with ultrasound derived variables baseline
Secondary • Days of ventilation (before weaning trial) in correlation to diaphragmatic dysfunction baseline
Secondary • Number of weaning trials prior to inclusion in the study baseline

External Links