Diabetes Free Completely Edentulous Patients Clinical Trial
Official title:
Detection of Pressure Areas for Elastomeric Impressions With and Without Spacer Using Novel Digital Analyzing Software and Its Correlation With Retention.A Randomized Clinical Trial.
| Verified date | July 2017 |
| Source | Cairo University |
| Contact | n/a |
| Is FDA regulated | No |
| Health authority | |
| Study type | Interventional |
Forty completely edentulous patients were selected and randomly distributed into two groups 20 patients each.Group I received complete dentures constructed from elastomeric impression with wax spacer,group II received complete dentures constructed from elastomeric impression with no wax spacer.then on time of denture insertion pressure areas were detected using pressure indicating paste and the denture retention was detected.The results showed less pressure areas in group I and more denture retention values than group II.
| Status | Completed |
| Enrollment | 40 |
| Est. completion date | July 1, 2017 |
| Est. primary completion date | July 1, 2017 |
| Accepts healthy volunteers | No |
| Gender | All |
| Age group | 50 Years to 60 Years |
| Eligibility |
Inclusion Criteria: - completely edentulous upper and lower arches. well to moderately developed ridges saliva of average viscosity and amount with normal temporomandibular joint Exclusion Criteria: diabetic patients radiation therapy signs of inflammation, ulceration or hyperplasia neurological disorders clicking or mandibular deviation. |
| Country | Name | City | State |
|---|---|---|---|
| Egypt | Nancy Nader Elsherbini | Cairo |
| Lead Sponsor | Collaborator |
|---|---|
| Cairo University |
Egypt,
Al-Ahmar AO, Lynch CD, Locke M, Youngson CC. Quality of master impressions and related materials for fabrication of complete dentures in the UK. J Oral Rehabil. 2008 Feb;35(2):111-5. Epub 2007 Dec 5. — View Citation
Masri R, Driscoll CF, Burkhardt J, Von Fraunhofer A, Romberg E. Pressure generated on a simulated oral analog by impression materials in custom trays of different designs. J Prosthodont. 2002 Sep;11(3):155-60. — View Citation
Wang CW, Shao Q, Sun HQ, Mao MY, Zhang XW, Gong Q, Xiao GN. Influence of inner circular sealing area impression method on the retention of complete dentures. Braz Dent J. 2015 Mar-Apr;26(2):198-202. doi: 10.1590/0103-6440201300383. Epub 2015 Apr 1. — View Citation
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | pressure areas | pressure indicating paste on the fitting surface ,then the surface was captured then saved as JPEG format then Analysis was done using Image J software | 1month | |
| Secondary | denture retention | using force gauge to give retentive values in Newtons | 1 month |