Cardiac Resynchronization Therapy Clinical Trial
Official title:
Revisit the Value of Imaging in Best Using CArdiac Resynchronization Therapy
Many studies have shown the benefits of cardiac resynchronization therapy (CRT) with biventricular pacing in patients with heart failure with left ventricular dysfunction. CRT restores contraction coordination between different regions of the left ventricle, which yields a significant improvement in LV systolic function, symptoms, exercise tolerance and quality of life. In the longer term, treatment with resynchronization induces a reverse remodeling of the left ventricle and a decrease in mortality and morbidity (hospitalization for heart failure). Nevertheless, even if a majority of patients treated with CRT feel the benefit, some (up to 40% depending on the response criteria of CRT) do not experience significant improvement (nonresponders). Echocardiography and imaging have not so far demonstrated their added value to optimize delivery of CRT. Monocentric promising work on limited numbers of patients, however, were carried out. Meanwhile, equipment for delivering CRT evolves and new probes with four poles stimulation of the left ventricle are now used. The objective of this research is to validate new sequences of ultrasound processing estimating the CRT. These tools are based on usual echocardiographic examination of patients
Pilot study for testing tools pre and post-treatment images echocardiography but also MRI with a descriptive purpose and identification of the computed parameters should be secondarily test a large multicenter cohort . Patients in the study will be explored in RICART preimplantation as then in the manner used in current clinical routine. The use of data by cons will focus on the study of new tools ever compared in the same patients. Data echocardiography (as with other techniques) are those used in clinical routine. Then, the data processing to be carried characterized the asynchrony posteriori, regardless of initial clinical data on a dedicated search software. Each quantitative parameter will be compared with others in order to predict the response to resynchronization. Response prediction of threshold values to the resynchronization can be obtained and compared to each of the tools. The value of relative and an addition to another may be tested. The predictive value of the change (delta) of each parameter between the pre- and post-implantation to predict response to al resynchronization, will be evaluated. ;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT05564689 -
Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy
|
||
| Completed |
NCT06444386 -
ECGi of SyncAV With MultiPoint Pacing
|
||
| Recruiting |
NCT01515761 -
POsition of Leads in Advanced heaRt Failure: the POLAR Study
|
N/A | |
| Completed |
NCT04595305 -
Septal Mapping And Resynchronisation Therapy- (SMART) Study
|
N/A | |
| Not yet recruiting |
NCT05985408 -
LVSP Based CRT vs. RVAP Based CRT
|
N/A | |
| Completed |
NCT04065893 -
Impact of Catheter Ablation of Ventricular Arrhythmias on Suboptimal Biventricular Pacing in Cardiac Resynchronization Therapy
|
||
| Completed |
NCT04505384 -
Acute Effects of LBBP Versus BVP for CRT
|
N/A | |
| Suspended |
NCT04347109 -
cArdiac Non Invasive MApping in resynchronizaTION
|
||
| Recruiting |
NCT02962791 -
Prospective Randomized Trial Comparing TRIPLE Site ventriculAr Stimulation Versus Conventional Pacing in CRT canDidates
|
N/A | |
| Recruiting |
NCT03587064 -
Comparison of CRT-D and CRT-DX Systems (CRT-NEXT)
|
N/A | |
| Recruiting |
NCT03301363 -
Simultaneous or Sequential Multipoint Pacing
|
||
| Recruiting |
NCT06105580 -
Conduction System Pacing vs Biventricular Pacing in Systolic Dysfunction and Wide QRS: Mortality, Heart Failure Hospitalization or Cardiac Transplant
|
N/A | |
| Recruiting |
NCT03415945 -
Left Ventricular Septal Pacing: Potential Application for Cardiac Resynchronization Therapy
|
N/A | |
| Completed |
NCT04299360 -
Comparison of Multi-point Pacing and Conventional CRT Through Non-invasive Hemodynamics Measurement and Global Longitudinal Strain Assessment
|
||
| Suspended |
NCT02728336 -
MRI Assessment of Patient Suitability for Cardiac Resynchronization Therapy (CRT)
|
N/A | |
| Completed |
NCT00395642 -
TRIAGE-CRT Telemonitoring in Patients With CHF and Indication of CRT-D
|
Phase 4 | |
| Completed |
NCT03367104 -
Narrow QRS HF Patients Assessed by ECG Belt
|
||
| Recruiting |
NCT05971225 -
Verifying Remote Monitoring Effect on Net Cardiovascular Outcome; RemoteVerify (RêVe)
|
N/A | |
| Terminated |
NCT04870281 -
Atrial Fibrillation Associated With Heart Failure Treated by BIOTRONIK's CRT-DX System
|
||
| Recruiting |
NCT05327062 -
Cardiac Resynchronization Therapy Delivery Guided Non-Invasive Electrical and Venous Anatomy Assessment
|
N/A |