Blood Gas Monitoring, Transcutaneous Clinical Trial
Official title:
The Accuracy of Non-invasive Continuous Carbon Dioxide Monitoring by the Sentec V-Sign Digital Monitor System
Arterial carbon dioxide partial pressure (PaCO2) is an essential indicator of ventilation and respiratory function. It is routinely tested invasively by arterial blood gas analysis (ABGA) but recently developed miniaturized carbon dioxide tension sensors promise non-invasive and continuous transcutaneous PCO2 (PtcCO2) monitoring. We, the researchers at University Hospital, Basel, Switzerland, determined the accuracy of two PtcCO2 monitors (TOSCA 500 with Sensor 92, Linde Medical Sensors AG, Basel; and Sentec Digital Monitor with V-Sign Sensor, Sentec AG, Therwil) for measurement of single values and trends in PaCO2 in critically ill patients, using ABGA as a reference.
Measurement of SO2 is used in nearly every patient receiving anesthesia or sedation, whereas monitoring of pCO2 is important in patients during and shortly after major surgery and in critically ill patients. But measurement of pCO2 requires arterial blood sampling and laboratory testing. Non-invasive monitors for continuous assessment of arterial pCO2 have been developed but their accuracy and feasibility were insufficient to make them useful in the clinical setting. Recently, a new digital system for continuous and non-invasive monitoring of arterial pCO2 and SO2 has been introduced (SenTec Digital Monitor System, SenTec AG, Therwil, Switzerland). This present study has been designed to evaluate the accuracy of the SenTec V-SignTM monitoring system for measuring pCO2 in comparison with repeated arterial blood gas testing in the operation room and in the intensive care unit. ;
Observational Model: Cohort, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03934515 -
End-Tidal CO2 (etCO2) and pH in the Correct Naso-gastric Tube Placement
|
||
Terminated |
NCT03156764 -
Qp/Qs Ratio by Noninvasive Methods in Children With Shunt Dependent Pulmonary Circulation
|
||
Completed |
NCT03992651 -
Optical Transcutaneous Sensors of Capnia and Oxygenation
|
N/A | |
Completed |
NCT03176589 -
Effect of PEP on Oxygen Saturation and Carbon Dioxide After Abdominal Surgery
|
N/A | |
Withdrawn |
NCT00420069 -
Biphasic Extrathoracic Cuirass Ventilation During Dental Treatment
|
N/A | |
Active, not recruiting |
NCT03224936 -
Propofolsleep - A Study on Cardiopulmonary and Pharyngeal Reactions While Drug Induced Sleep Endoscopy (DISE)
|