Mechanical Ventilation Complication Clinical Trial
Official title:
Determining the Appropriate Setting of an Automated Secretion Removal Technology (TrachFlush) Danish Title: Bestemmelse af Den Optimale Indstilling for en Teknologi Til Automatisk Fjernelse af Luftvejssekret (Trachflush)
Using a new device, the TrachFlush, the aim of this pilot study is to investigate whether secretions can be removed at the patient's current ventilator settings, or whether pressures and durations considered at the maximal end of clinical practice are required, so as to push secretions around the cuff. The study is a pilot study to investigate the settings required to ensure clinical efficacy of the technology, prior to large scale clinical studies.
Design: Prospective, non-controlled, pilot study of the TrachFlush© technology on 20 patients, mechanically ventilated in the intensive care unit. Study procedure This study is designed to evaluate whether the TrachFlush technology the symptoms associated with need of tracheal suctioning, when applied at the patient's current ventilator settings, or following a change in ventilator settings to the maximal inspiratory pressure and time acceptable in clinical practice. Figure 2 illustrates the protocol procedure. Patients will be studied during mechanical ventilation when on pressure control or pressure support mode. When recruited, and on clinical need for suctioning, the patient will be evaluated to see if they are eligible for the TrachFlush procedure. If the patient is on a volume regulated mode; has an inspiratory time < 1 second; has a value of positive end expiratory pressure >15 cmH2O; has a PaO2 (arterial partial pressure of oxygen)/FiO2 (fraction of inspired oxygen) ratio lower that 100 mmHg, i.e. indicative of severe ARDS (acute respiratory distress syndrome); or has tachycardia defined as >120 bpm then the patient will be considered ineligible for the procedure. As such, the patient will be considered again on the next clinical need for suctioning. On detection of a clinical need for suctioning, and when the patient is eligible for the TrachFlush procedure, the reason for suctioning will be documented - as inadequate oxygenation, rising ventilation pressures with disturbing ventilation pressure waveforms, or audible sounds of secretions. The TrachFlush procedure will then be performed following the 5 steps described below: 1. Ventilator settings for inspiratory pressure, positive end expiratory pressure and, for control mode, respiratory rate will be maintained at current clinical values. 2. The TrachFlush "button" will be pressed three times over a period of 1 minute, allowing 3 cuff deflations and inflations during 3 non-consecutive inspirations. As the procedure is rapid, no pre-oxygenation will be performed. SpO2 (oxygen saturation) will be monitored continuously and oxygen flushing applied immediately, should oxygenation deteriorate. 3. Following this procedure, clinical indications towards the need of suctioning will be re-evaluated and recorded, with two possible outcomes as evaluated by the investigator at the bedside. i. Success - Clinical state is such that endotracheal suctioning is no longer required. ii. Failure - Clinical state has not improved sufficiently. For case 1 suctioning is not performed, suctioning of the mouth is permitted. For case 2, ventilator settings are adjusted to a maximal safe level for the short duration, i.e. PEEP(positive end expiratory pressure) and pressure support or pressure control will be increased such that the sum of these, i.e. the peak pressure is 30 cmH20. In doing so, PEEP will not be > 15 cmH2O. For control mode ventilation, if respiratory rate is higher than 10 breaths per minute, this will be reduced to 10, to allow increase in inspiratory time. In addition, the TrachFlush device will be set to deliver the cuff deflation and inflation over a longer period, allowing increased time to remove secretions. This setting can be performed directly on the device and will be set to be 100 ms lower than the inspiratory time achieved with a respiratory rate of 10, allowing for full cuff deflation and inflation within this period. For either of these situations, if current settings are already at maximal pressure and minimal respiratory frequency, the protocol will move to step 5, with that step recorded as a failure. 4. Following modification of ventilator settings, the TrachFlush "button" will be pressed three times over a period of 1 minute, allowing 3 cuff deflations and inflations during 3, non-consecutive inspirations, as previously described. 5. Following this procedure, clinical indications of the need for suctioning will be re-evaluated and recorded, with two possible outcomes. i. Success - Clinical state is such that endotracheal suctioning is no longer required. Suctioning of the mouth is permitted. ii. Failure - Clinical state has not improved sufficiently. 6. Ventilator settings will be returned to baseline values and following failure of the TrachFlush procedure, clinical suctioning will be performed if necessary and in accordance with normal clinical practice. All tasks will be performed by the research team associated with the project. To assess intra-patient variability, the above procedure will be performed 3 times on the same patient, for three different occasions where there is a need for airway suctioning. As an average of 3 suctions are performed routinely per patient per day, it is expected that this study will take 1 day with a maximum of 2 days per patient. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05030337 -
Optimising Ventilation in Preterms With Closed-loop Oxygen Control
|
N/A | |
Completed |
NCT05144607 -
Impact of Inspiratory Muscle Pressure Curves on the Ability of Professionals to Identify Patient-ventilator Asynchronies
|
N/A | |
Recruiting |
NCT03697785 -
Weaning Algorithm for Mechanical VEntilation
|
N/A | |
Completed |
NCT05084976 -
Parental Perception of COVID-19 Vaccine in Technology Dependent Patients
|
||
Active, not recruiting |
NCT05886387 -
a Bayesian Analysis of Three Randomised Clinical Trials of Intraoperative Ventilation
|
||
Completed |
NCT04429399 -
Lowering PEEP: Weaning From High PEEP Setting
|
N/A | |
Completed |
NCT02249039 -
Intravenous Clonidine for Sedation in Infants and Children Who Are Mechanically Ventilated - Dosing Finding Study
|
Phase 1 | |
Recruiting |
NCT02071524 -
Evaluation of the Effects of Fluid Therapy on Respiratory Mechanics
|
N/A | |
Completed |
NCT01114022 -
Prevention Inhalation of Bacterial by Using Endotracheal Tube Balloon Polyvinyl Chloride or Polyurethane
|
N/A | |
Completed |
NCT00893763 -
Strategies To Prevent Pneumonia 2 (SToPP2)
|
Phase 2 | |
Terminated |
NCT05056103 -
Automated Secretion Removal in ICU Patients
|
N/A | |
Active, not recruiting |
NCT04558476 -
Efficacy of CONvalescent Plasma in Patients With COVID-19 Treated With Mechanical Ventilation
|
Phase 2 | |
Recruiting |
NCT05295186 -
PAV Trial During SBT Trial
|
||
Active, not recruiting |
NCT05370248 -
The Effect of 6 ml/kg vs 10 ml/kg Tidal Volume on Diaphragm Dysfunction in Critically Mechanically Ventilated Patient
|
N/A | |
Completed |
NCT04589910 -
Measuring Thickness of the Normal Diaphragm in Children Via Ultrasound.
|
N/A | |
Completed |
NCT04818164 -
Prone Position Improves End-Expiratory Lung Volumes in COVID-19 Acute Respiratory Distress Syndrome
|
||
Completed |
NCT04193254 -
LPP , MP and DP:Relation With Mortality and SOFA in Mechanically Ventilated Patients in ER, Ward and ICU
|
||
Completed |
NCT06332768 -
NIV Versus HFO Versus Standard Therapy Immediately After Weaning From Mechanical Ventilation in ARDS Patients
|
N/A | |
Not yet recruiting |
NCT03245684 -
Assisted or Controlled Ventilation in Ards (Ascovent)
|
N/A | |
Not yet recruiting |
NCT03259854 -
Non Invasive Mechanical Ventilation VERSUS Oxygen MASK
|
N/A |