Osteoarthritis of the Knee Clinical Trial
Official title:
Comparison Between Cooled (C-RFA) and Standard (t-RFA) Radiofrequency Ablation, and Control for Pain Management Following Unilateral Knee Arthroplasty: A Double-Blinded, Parallel-Grouped, Placebo-Controlled Randomized Clinical Trial
Three primary reasons prolong hospital stays following unilateral knee arthroplasty. Pain is the primary reason followed by opioid drowsiness and nausea/vomiting side effects. Standard genicular radiofrequency ablation (t-RFA) has been effective pain management for non-operative knee pain associated with osteoarthritis. Additionally, cooled radiofrequency ablation (C-RFA), is now available for knee pain management. Both t-RFA and C-RFA offer minimally invasive, non-surgical, non-opioid pain relief options following surgery. The study will perform a double-blinded, parallel grouped, placebo-controlled randomized study to compare three pain management paradigms involving preoperative genicular C-RFA, t-RFA, and control placebo/sham. The aim of this study is to establish if C-RFA and t-RFA, offered preoperatively to patients undergoing unilateral knee arthroplasty, provide postoperative pain relief.
Total knee replacements are a leading orthopedic procedure in the United States totaling 600,000 in 2010, and are anticipated to grow to 3.48 million procedures by 2030. Three primary reasons prolong hospital stays following unilateral knee arthroplasty. Pain is the primary reason followed by opioid drowsiness and nausea/vomiting side effects. Reducing opioid usage and decreasing hospital length of stays are paramount in improving patient care during recovery and rehabilitation, subsequently reducing overall costs associated with total knee replacement. Standard genicular radiofrequency ablation (t-RFA) has been effective pain management for non-operative knee pain associated with osteoarthritis. Additionally, cooled radiofrequency ablation (C-RFA), which was previously used for spinal pain, is now available for knee pain management. C-RFA, compared to t-RFA, causes large volume spherical lesions and potentially reduces time and fluoroscopic exposure with direct placement techniques. However, both t-RFA and C-RFA offer a minimally invasive, non-surgical, non-opioid pain relief options following surgery. Preliminary reports involving 40 patients who underwent either C-RFA or t-RFA prior to unilateral knee arthroplasty by the investigator indicate both procedures improved postoperative pain assessments and decreased opioid/narcotic utilization. The study will perform a double-blinded, parallel grouped, placebo-controlled randomized study to compare three pain management paradigms involving preoperative C-RFA, t-RFA, and sham. The aim of this study is to establish if C-RFA and t-RFA, offered preoperatively to patients undergoing unilateral knee arthroplasty, provide postoperative pain relief, reduce hospital length of stays and decrease opioid utilization thereby improving patient outcomes and decreasing overall costs. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03277066 -
A 4-week Study to Evaluate the Efficacy and Safety of HP-5000 in Subjects With Knee Osteoarthritis
|
Phase 2 | |
Recruiting |
NCT03090698 -
Outcomes of Injections in Patients Waiting for Total Knee Replacement
|
Phase 4 | |
Completed |
NCT02556710 -
A Study to Evaluate the Efficacy & Safety of an Intra-Articular Ampion Injection for Pain of Osteoarthritis of the Knee
|
Phase 3 | |
Withdrawn |
NCT02237846 -
Clinical Study of Umbilical Cord Tissue Mesenchymal Stem Cells (UC-MSC) for Treatment of Osteoarthritis
|
Phase 1/Phase 2 | |
Completed |
NCT02242435 -
A Multiple Injection Study Evaluating Safety and Efficacy of Ampion in Osteoarthritis
|
Phase 3 | |
Completed |
NCT02096393 -
Patient Specific Instrumentation in TKR
|
N/A | |
Completed |
NCT01849445 -
Targeted Rehabilitation to Improve Outcome After Knee Replacement- A Physiotherapy Study
|
N/A | |
Completed |
NCT01704157 -
A Prospective Study Evaluating the Treatment of Knee Osteoarthritis With the Cryo-Touch III Device
|
N/A | |
Active, not recruiting |
NCT01374230 -
Long-Term Multicenter Evaluation of the E1® Tibial Bearing
|
N/A | |
Not yet recruiting |
NCT01270412 -
Platelet Rich Plasma (PRP) as a Treatment for Knee Osteoarthritis PRP as a Treatment for Knee Osteoarthritis
|
Phase 2/Phase 3 | |
Completed |
NCT02156440 -
Cross-over Study of the Efficacy and Safety of SierraSil Joint Formula 14 in Osteoarthritis of the Knee
|
Phase 2 | |
Completed |
NCT01410409 -
Structured Treatment of Osteoarthritis of the Knee With or Without Total Knee Replacement
|
N/A | |
Completed |
NCT01207115 -
A Study of ABT-652 in Adults With Osteoarthritis Pain of the Knee
|
Phase 2 | |
Completed |
NCT00970008 -
Exploring Massage Benefits for Arthritis of the Knee
|
Phase 2 | |
Completed |
NCT00988091 -
Investigation of 1.2% Sodium Hyaluronate for Treatment of Painful Chronic Osteoarthritis of the Knee
|
Phase 3 | |
Completed |
NCT01331278 -
A Comparative Study of Knee Systems
|
Phase 4 | |
Completed |
NCT00531427 -
Buprenorphine Transdermal System (BTDS) in Subjects w/Mod-sev Osteoarthritis (OA) Chronic Pain of Knee
|
Phase 3 | |
Completed |
NCT00792727 -
HKT-500 in Adult Patients With Osteoarthritis (OA) Knee Pain
|
Phase 3 | |
Completed |
NCT00449696 -
Gel-200 Versus Placebo in Osteoarthritis of the Knee
|
Phase 3 | |
Completed |
NCT04145011 -
Coolief Cooled Radiofrequency vs. Conventional Radiofrequency to Manage OA Knee Pain
|
N/A |