Osteoarthritis, Knee Clinical Trial
Official title:
Comportement Electrochimique d'Alliages Biomedicaux Dans Des Liquides Synoviaux en Fonction de l'Etat Pathologique
Biomedical implant metals are reactive when in contact with body fluids. Some reactions may adverse the biocompatibility character of the material and should be studied. This can be achieved by direct measurement through electrochemical, gravimetric, spectrophotometric and surface analysis of reaction occurring at the interface between functionalized metal samples and body fluids (synovia) directly extracted from patients. The general aim of this project is to contribute to develop a comprehensive vision of interfacial reactions occurring on biomedical alloy surfaces exposed to human synovial fluid and to link them to clinical data
Most widely used biomedical materials are polymeric, ceramics and metals. Among these materials, metals exhibit a unique combination of mechanical strength, toughness, wear resistance and forming easiness. Metals are chemically reactive when in contact with body fluids. While some of the reactions are welcome, such as the surface oxidation providing corrosion protection, other reactions may adverse the biocompatibility character of the material.The understanding of these reactions is the object of several studies. Corrosion scientists try to characterise the corrosion response of metals when in contact with simulated body fluids in order to verify the occurrence of hypothetical mechanisms. Biologists look at specific reaction products expected to be released by cells when set in contact with structured or functionalized surfaces. These approaches are necessary but also time consuming due to the complexity of possible reaction mechanisms. As complement to these deductive approaches we propose here an inductive one based on direct measurement through electrochemical, gravimetric, spectrophotometric and surface analysis of reaction occurring at the interface between functionalized metal samples and body fluids (synovia) directly extracted from patients. The general aim of this project is to contribute to develop a comprehensive vision of interfacial reactions occurring on biomedical alloy surfaces exposed to human synovial fluid and to link them to clinical data. This will be achieved through a collaboration between surgeons and corrosion scientists. The synovial fluid will be extracted form patients using an established procedure and transferred to a portable sterile corrosion laboratory located close to the surgery room. There, surface reaction will be characterized using electrochemical methods already successfully applied in recent studies carried out by the same team. We will be integrating in-situ quartz crystal microgravimetry and in-situ Raman spectroscopy as well as ex-situ methods. Further, metal surfaces will be chemically functionalized (wettability, oxidation, surface charge) in order to selectively influence specific reactions of body fluid components (i.e. adsorption depends on surface energy and wettability while Redox reactions are influenced by the oxidation state of the surface. The acquired information will be compared to the clinical state of the patient in order to establish possible correlations between interface reactivity and patient state. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT03895489 -
Effectiveness of the Journey Total Knee Arthroplasty Versus Two Standard of Care Total Knee Arthroplasty Prostheses
|
N/A | |
Completed |
NCT03660943 -
A Clinical Study to Test Efficacy and Safety of Repeat Doses of CNTX-4975-05 in Patients With Osteoarthritis Knee Pain
|
Phase 3 | |
Completed |
NCT04531969 -
Comparison of Outpatient and Inpatient Spa Therapy
|
N/A | |
Completed |
NCT02848027 -
Correlating the Osteoarthritic Knee Microenvironment to Clinical Outcome After Treatment With Regenexx®SD Treatment
|
Phase 3 | |
Completed |
NCT05160246 -
The Instant Effect of Kinesiology Taping in Patients With Knee OA
|
N/A | |
Recruiting |
NCT06080763 -
Biomechanics and Clinical Outcomes in Responders and Non-Responders
|
||
Completed |
NCT03643588 -
The Comparison of HYAJOINT Plus and Hyalgan Hyaluronan Supplement for Knee Osteoarthritis Pain
|
N/A | |
Active, not recruiting |
NCT05100225 -
Efficacy and Safety Trial of PTP-001 (MOTYS) for Symptomatic Knee Osteoarthritis
|
Phase 2 | |
Active, not recruiting |
NCT04061733 -
New Hydroxyethyl Cellulose Hydrogel for the Treatment of the Pain of Knee Arthrosis
|
N/A | |
Completed |
NCT04051489 -
A Novel Smartphone Application for "Smart" Knee Osteoarthritis Trials
|
||
Recruiting |
NCT05546541 -
Epidemiology and Nutrition
|
||
Recruiting |
NCT05447767 -
Prediction AlgoriThm for regeneraTive Medicine Approach in knEe OA: New Decision-making Process Based on Patient pRofiliNg
|
Phase 2 | |
Not yet recruiting |
NCT04448106 -
Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis
|
Phase 2 | |
Not yet recruiting |
NCT03225911 -
Effect of a Lateral Wedge Insole and Simple Knee Sleeve in Individuals With Knee Osteoarthritis
|
N/A | |
Completed |
NCT05070871 -
A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women
|
N/A | |
Completed |
NCT05703087 -
Positive Cueing in Knee Arthroplasty.
|
N/A | |
Not yet recruiting |
NCT06042426 -
Effects of Perioperative Intravenous Dexamethasone in Clinical Outcomes After Total Knee Arthroplasty in a Hispanic Population
|
Phase 4 | |
Not yet recruiting |
NCT02865174 -
Topical Tranexamic Acid and Floseal® in Total Knee Arthroplasty
|
Phase 4 | |
Completed |
NCT02901964 -
Effect of Strengthening the Hip Abductor in Patients With Knee Osteoarthritis: Randomized Controlled Trial
|
N/A | |
Not yet recruiting |
NCT02826850 -
Saphenous Nerve Radiofrequency for Knee Osteoarthritis Trial
|
Phase 3 |