Clinical Trials Logo

Clinical Trial Summary

Knee osteoarthritis (KOA) patients, have impairments in gait and balance. Accurate gait and postural balance analysis is needed to detect this impairments. Nevertheless methodological quality about the recording of gait and balance analysis in KOA patients is lacking in literature.


Clinical Trial Description

In patients with knee osteoarthritis (KOA), impairments in gait and balance are well recognized and therefore objective and accurate gait and postural balance analysis is crucial to detect potential alterations in balance and gait function in this patient group. Gait analysis in orthopaedic patients has been mainly investigated during level walking at a self-selected speed or at pre-determined gait velocities. Nevertheless, walking at a comfortable speed may not necessary result in any gait impairments and therefore the use of more challenging tasks is probably required. In addition, some patients are not able to walk at a required walking speed or slope, because of pain and disability. Therefore it seems reasonable to evaluate gait parameters of KOA patients while walking at different speeds and surface inclinations. Postural balance parameters are also important outcome measures in the assessment of KOA patients. Postural stability is generally assessed throughout the quantification of the displacement and velocity of the centre of pressure (COP) with larger excursions and higher velocities indicating poorer balance. Recently, instrumented treadmill systems (ITS) have been introduced for the evaluation of spatiotemporal and kinetic gait as well as postural balance parameters throughout a capacitance-based foot pressure platform. Further, they permit an assessment of the gait parameters at different speeds and slopes. Spatiotemporal and kinetic gait parameters provided by ITS have been shown to be valid and reliable during level walking in healthy young and elderly persons and during walking at different speeds and slopes. ITS can also be used for the quantification of static balance, because they are able to provide the velocity and displacement changes of COP. However the validity and reliability of gait and postural balance analysis at different slopes and speeds in patients with KOA are lacking. Similarly to ITS, photoelectric cell systems (PCS) also permit the quantification of spatiotemporal gait parameters but in addition they are portable, their set up is very quick, they are relatively cheap and can be adapted to a treadmill. PCS have been shown to be both valid and reliable for the assessment of spatiotemporal gait parameters in healthy adults and also in KOA patients. The main aim of this study is to evaluate the methodological quality of postural and gait parameters assessed at different treadmill inclinations and velocities using an ITS in patients with KOA. In particular, we will investigate the test-retests reliability, the discriminant validity and the concurrent validity. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02543736
Study type Interventional
Source Schulthess Klinik
Contact
Status Completed
Phase N/A
Start date July 2015
Completion date September 2016

See also
  Status Clinical Trial Phase
Recruiting NCT03895489 - Effectiveness of the Journey Total Knee Arthroplasty Versus Two Standard of Care Total Knee Arthroplasty Prostheses N/A
Completed NCT03660943 - A Clinical Study to Test Efficacy and Safety of Repeat Doses of CNTX-4975-05 in Patients With Osteoarthritis Knee Pain Phase 3
Completed NCT04531969 - Comparison of Outpatient and Inpatient Spa Therapy N/A
Completed NCT02848027 - Correlating the Osteoarthritic Knee Microenvironment to Clinical Outcome After Treatment With Regenexx®SD Treatment Phase 3
Completed NCT05160246 - The Instant Effect of Kinesiology Taping in Patients With Knee OA N/A
Recruiting NCT06080763 - Biomechanics and Clinical Outcomes in Responders and Non-Responders
Completed NCT03643588 - The Comparison of HYAJOINT Plus and Hyalgan Hyaluronan Supplement for Knee Osteoarthritis Pain N/A
Active, not recruiting NCT05100225 - Efficacy and Safety Trial of PTP-001 (MOTYS) for Symptomatic Knee Osteoarthritis Phase 2
Active, not recruiting NCT04061733 - New Hydroxyethyl Cellulose Hydrogel for the Treatment of the Pain of Knee Arthrosis N/A
Completed NCT04051489 - A Novel Smartphone Application for "Smart" Knee Osteoarthritis Trials
Recruiting NCT05546541 - Epidemiology and Nutrition
Recruiting NCT05447767 - Prediction AlgoriThm for regeneraTive Medicine Approach in knEe OA: New Decision-making Process Based on Patient pRofiliNg Phase 2
Not yet recruiting NCT04448106 - Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis Phase 2
Not yet recruiting NCT03225911 - Effect of a Lateral Wedge Insole and Simple Knee Sleeve in Individuals With Knee Osteoarthritis N/A
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Completed NCT05703087 - Positive Cueing in Knee Arthroplasty. N/A
Not yet recruiting NCT06042426 - Effects of Perioperative Intravenous Dexamethasone in Clinical Outcomes After Total Knee Arthroplasty in a Hispanic Population Phase 4
Not yet recruiting NCT02854176 - Somatosensory Stimulation in Knee Osteoarthritis Phase 2
Completed NCT02905747 - The Effect of Medical Exercise Therapy on Pain, Function and Physical Activity in Patients With Knee Osteoarthritis N/A
Completed NCT02901964 - Effect of Strengthening the Hip Abductor in Patients With Knee Osteoarthritis: Randomized Controlled Trial N/A