Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02444663
Other study ID # 109367
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date January 13, 2016
Est. completion date December 14, 2016

Study information

Verified date October 2021
Source Oxford University Hospitals NHS Trust
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

X-rays are the most frequently used imaging test when evaluating the knee for joint replacement. They are non-invasive, safe and cost effective. They allow assessment of: progression of disease, appropriateness for joint replacement (in particular unicompartmental knee replacement (UKR)) as well as likely prognosis following replacement. Currently standard assessment involves: standing anteroposterior, lateral and skyline X-ray views. In addition in patients being considered for joint replacement valgus/varus stress X-rays are used to evaluate the lateral compartment (as well as medial collateral ligament) and medial compartment respectively to assess the status of the cartilage. Stress X-rays require the clinician to attend X-ray, often during busy clinics, exposing them to additional radiation, and as such they are seldom performed. A patient and user friendly device for performing valgus and varus stress X-rays of the knee for diagnostic and pre-operative planning purposes in the setting of knee replacement surgery has been developed. This device has the potential to benefit patients as it will allow an accurate assessment of the pattern and severity of arthritis affecting their knee without the need for additional diagnostics such as MRI or arthroscopy. Furthermore for healthcare practitioners and providers this device will facilitate the smooth running of clinics and reduce the additional clinic appointments required to review MRI results. Ultimately this device will allow an informed discussion about treatment options, reduce the pre-operative uncertainty about suitability for UKR in those undergoing surgery and ensure that those patients who are suitable for UKR benefit from this procedure. This device will help ensure that patients receive the optimum treatment in a clinically and cost efficient manner. This study will validate valgus and varus stress X-rays performed using the investigators' device against the gold standard of clinician performed manual stress.


Description:

X-rays are the most frequently used imaging test when evaluating the knee for joint replacement. They are non-invasive, safe and cost effective. They allow assessment of: progression of disease, appropriateness for joint replacement (in particular unicompartmental knee replacement (UKR)) as well as likely prognosis following replacement. Currently standard assessment involves: standing anteroposterior, lateral and skyline X-ray views. In addition in patients being considered for joint replacement valgus/varus stress X-rays are used to evaluate the lateral compartment (as well as medial collateral ligament) and medial compartment respectively to assess the status of the cartilage. The assessment of pattern and severity of disease is critical when evaluating suitability for joint replacement and well as when deciding between total knee replacement (TKR), where all articulating surface are replaced, or UKR, where only the diseased portion of the joint is replaced. Understanding the pattern of disease is essential to ensure appropriate patient selection for UKR, which is appropriate in up to half of patients undergoing knee replacement, and has significant benefits over TKR including: half the risk of venous thromboembolism, myocardial infarction or deep infection, two thirds the risk of stroke, one quarter the risk of blood transfusion and significantly lower mortality up to eight years following their operation. Stress X-rays are currently performed by the clinician, requiring them to attend radiology, often during clinic. To perform the stress views the clinician fixes the knee and moves the tibia away from the midline, valgus stress, where an X-ray is taken. The alignment of this view is confirmed before the tibia is moved towards the midline, varus stress, where another X-ray is taken. Stress X-rays are resource dependent and can be time consuming. In addition, the technique can be uncomfortable for patients as well as resulting in additional radiation exposure to the clinical practitioner. On an average, a knee surgeon may be exposing themselves to excess of 300 exposures every year with the cumulative effect of radiation exposure being significant. As such in many centers stress views are often not performed, and as standing antero-posterior X-ray views are inadequate to assess disease severity and pattern many clinicians have adopted additional imaging modalities such as MRI or direct observation via arthroscopy to evaluate the status of the cartilage in each compartment. The use of these additional imaging techniques introduces significant additional costs as well as delays to treatment. Furthermore the long term outcomes of UKR have been established using stress views, and as a consequence outcomes based on MRI or arthroscopic findings have not been fully established. A patient and user friendly device for performing valgus and varus stress X-rays of the knee for diagnostic and pre-operative planning purposes in the setting of knee replacement surgery has been developed. This device has the potential to benefit patients as it will allow an accurate assessment of the pattern and severity of arthritis affecting their knee without the need for additional diagnostics such as MRI or arthroscopy. Furthermore for healthcare practitioners and providers this device will facilitate the smooth running of clinics and reduce the additional clinic appointments required to review MRI results. Ultimately this device will allow an informed discussion about treatment options, reduce the pre-operative uncertainty about suitability for UKR in those undergoing surgery and ensure that those patients who are suitable for UKR benefit from this procedure. This device will help ensure that patients receive the optimum treatment in a clinically and cost efficient manner. This study will validate valgus and varus stress X-rays performed using the investigators' device against the gold standard of clinician performed manual stress.


Recruitment information / eligibility

Status Completed
Enrollment 9
Est. completion date December 14, 2016
Est. primary completion date December 14, 2016
Accepts healthy volunteers No
Gender All
Age group 50 Years and older
Eligibility Inclusion Criteria: - Participant is willing and able to give informed consent for participation in the study. - Male or Female, aged 50 years or above. - Knee osteoarthritis any grade, affecting the tibio-femoral joint - In the Investigator's opinion, is able and willing to comply with all trial requirements. - Willing to allow his or her General Practitioner and consultant, if appropriate, to be notified of participation in the trial. Exclusion Criteria: - Previous joint replacement on ipsilateral knee - Previous anterior cruciate ligament reconstruction or injury - Previous high tibial osteotomy - Previous intra-articular fracture - History of Inflammatory arthritis

Study Design


Related Conditions & MeSH terms


Intervention

Radiation:
Clinician Valgus
Clinician performed valgus stress X-ray under fluoroscopy
Clinician Varus
Clinician performed varus stress X-ray under fluoroscopy
Device Valgus - 0 Newton
Device (Oxford Stress System for Knee Arthroplasty Radiographs (OSSKAR)) performed valgus stress X-ray under fluoroscopy.
Device Valgus - 10 Newton
Device (Oxford Stress System for Knee Arthroplasty Radiographs (OSSKAR)) performed varus stress X-ray under fluoroscopy.
Device Valgus - 20 Newton
Device (Oxford Stress System for Knee Arthroplasty Radiographs (OSSKAR)) performed valgus stress X-ray under fluoroscopy.
Device Valgus - 30 Newton
Device (Oxford Stress System for Knee Arthroplasty Radiographs (OSSKAR)) performed valgus stress X-ray under fluoroscopy.
Device Varus - 0 Newton
Device (Oxford Stress System for Knee Arthroplasty Radiographs (OSSKAR)) performed valgus stress X-ray under fluoroscopy.
Device Varus - 10 Newton
Device (Oxford Stress System for Knee Arthroplasty Radiographs (OSSKAR)) performed valgus stress X-ray under fluoroscopy.
Device Varus - 20 Newton
Device (Oxford Stress System for Knee Arthroplasty Radiographs (OSSKAR)) performed valgus stress X-ray under fluoroscopy.
Device Varus - 30 Newton
Device (Oxford Stress System for Knee Arthroplasty Radiographs (OSSKAR)) performed valgus stress X-ray under fluoroscopy.

Locations

Country Name City State
n/a

Sponsors (2)

Lead Sponsor Collaborator
Oxford University Hospitals NHS Trust University of Oxford

Outcome

Type Measure Description Time frame Safety issue
Primary Compartment Specific Knee Minimum Joint Space Width (Varus - Medial Compartment, Valgus - Lateral Compartment) Knee minimum joint space width measured on anteroposterior fluoroscopic images using custom, validated, in house software (KneeMorph, MATLAB, MathWorks, Massachusetts). Day 0
Secondary Pain (VAS 0 - 10) Pain Score during stress radiographs (VAS 0 - 10) where a higher score represents more pain (10 = worst pain). At time of procedure
See also
  Status Clinical Trial Phase
Recruiting NCT03895489 - Effectiveness of the Journey Total Knee Arthroplasty Versus Two Standard of Care Total Knee Arthroplasty Prostheses N/A
Completed NCT03660943 - A Clinical Study to Test Efficacy and Safety of Repeat Doses of CNTX-4975-05 in Patients With Osteoarthritis Knee Pain Phase 3
Completed NCT04531969 - Comparison of Outpatient and Inpatient Spa Therapy N/A
Completed NCT02848027 - Correlating the Osteoarthritic Knee Microenvironment to Clinical Outcome After Treatment With Regenexx®SD Treatment Phase 3
Completed NCT05160246 - The Instant Effect of Kinesiology Taping in Patients With Knee OA N/A
Recruiting NCT06080763 - Biomechanics and Clinical Outcomes in Responders and Non-Responders
Completed NCT03643588 - The Comparison of HYAJOINT Plus and Hyalgan Hyaluronan Supplement for Knee Osteoarthritis Pain N/A
Active, not recruiting NCT05100225 - Efficacy and Safety Trial of PTP-001 (MOTYS) for Symptomatic Knee Osteoarthritis Phase 2
Active, not recruiting NCT04061733 - New Hydroxyethyl Cellulose Hydrogel for the Treatment of the Pain of Knee Arthrosis N/A
Completed NCT04051489 - A Novel Smartphone Application for "Smart" Knee Osteoarthritis Trials
Recruiting NCT05546541 - Epidemiology and Nutrition
Recruiting NCT05447767 - Prediction AlgoriThm for regeneraTive Medicine Approach in knEe OA: New Decision-making Process Based on Patient pRofiliNg Phase 2
Not yet recruiting NCT04448106 - Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis Phase 2
Not yet recruiting NCT03225911 - Effect of a Lateral Wedge Insole and Simple Knee Sleeve in Individuals With Knee Osteoarthritis N/A
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Completed NCT05703087 - Positive Cueing in Knee Arthroplasty. N/A
Not yet recruiting NCT06042426 - Effects of Perioperative Intravenous Dexamethasone in Clinical Outcomes After Total Knee Arthroplasty in a Hispanic Population Phase 4
Not yet recruiting NCT02865174 - Topical Tranexamic Acid and Floseal® in Total Knee Arthroplasty Phase 4
Completed NCT02905747 - The Effect of Medical Exercise Therapy on Pain, Function and Physical Activity in Patients With Knee Osteoarthritis N/A
Completed NCT02881775 - Immediate Effects of rTMS on Excitability of the Quadriceps With Knee Osteoarthritis N/A