Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01797731
Other study ID # 10137
Secondary ID
Status Completed
Phase N/A
First received February 7, 2013
Last updated July 10, 2017
Start date December 2010
Est. completion date September 16, 2013

Study information

Verified date July 2017
Source Hospital for Special Surgery, New York
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This is a randomized, controlled, blinded prospective study comparing the use of the usual cutting guides with a palm-sized digital surgical navigation system in unilateral total knee arthroplasty. Analysis of pre- and post-operative X-rays will be used to compare alignment of the tibial (shinbone) implant components. The investigators expect that the FDA-approved hand-held surgical navigation device will increase the accuracy and precision of the tibial cut by telling the surgeon the exact position of the cutting block before the surgeon makes the cut, allowing minor adjustments to be made. The investigators expect the conventional device to take less time to use, but that this difference will decrease as the surgeon becomes more familiar with the device. The investigators expect the intraoperative measurements acquired by the KneeAlign system to strongly correlate with the radiographic alignments measured postoperatively.


Description:

Medical records, private office charts, and electronic medical records will be utilized by the co-investigators to review data on patients who fit the previously stated inclusion criteria. Demographic data including age, gender, height (cm), and weight (kg) will be collected. Preoperative, standing anteroposterior hip-to-ankle radiographs will be measured for the lower extremity mechanical axis, the tibiofemoral anatomic alignment, and the distal femoral and proximal tibial anatomic angles. Intraoperative time measurements for use of both the conventional extramedullary alignment guide, and the KneeAlignTM system will be measured and recorded. The time required to utilize each alignment guide will be measured in seconds, starting from the time at which the surgeon is handed the alignment guide (KneeAlignTM or conventional, extramedullary), to the time at which the surgeon is handed the oscillating saw to make the tibial cut. Of note, no intraoperative alignment measurements are required or will be recorded for the conventional, extramedullary systems, while intraoperative alignments reported by the KneeAlignTM system will be recorded when the KneeAlignTM device is used. In addition, regarding the use of conventional, extramedullary tibial guides, each surgeon will utilize the guide (regardless of manufacturer) which they currently use most frequently when performing a total knee arthroplasty. While there may be minimal differences with regards each of the surgeon's conventional guides, they are all essentially the same with regards to utilizing an extramedullary rod for alignment of the tibial resection.

Currently, a total knee replacement requires an average tourniquet time of 30-50 minutes depending on the surgeon. We estimate an approximate increase in total tourniquet time of 5-6 minutes when using the hand-held surgical navigation system.

For each procedure (either KneeAlignTM or conventional, extramedullary guides), after making the initial cut, if at any point in the procedure the surgeon re-cuts the tibia, they will be asked a series of questions postoperatively as to why they re-cut the tibia as part of the data collection. These questions will include:

1. Did you re-cut the tibia because you thought more varus or valgus was required?

2. Did you re-cut the tibia to increase or decrease the posterior slope?

3. Did you re-cut the tibia to increase the amount of bone resected?

4. Were you happy with the overall tibial alignment? Postoperative radiographs will be obtained as part of each surgeon's postoperative protocol, and will include a standing anteroposterior hip-to-ankle radiograph and a standing lateral knee-to-ankle radiograph, from which the lower extremity mechanical axis, the tibiofemoral anatomic alignment, the tibial component mechanical alignment, and the tibial component posterior slope will be measured.

This study has the potential to provide significant information regarding the clinical accuracy and precision of the KneeAlignTM system compared to that of conventional, extramedullary alignment systems. If mechanical and tibial mechanical alignment is significantly improved with the use of the KneeAlignTM system, this may encourage surgeons to utilize this device to improve postoperative alignment in total knee arthroplasty. In addition, surgeon's may find this type of hand-held system more user-friendly (in contrast to a large console, computer-assisted surgical system), and this may stimulate future investigations into similar devices for femoral component alignment, and also total hip arthroplasty.


Recruitment information / eligibility

Status Completed
Enrollment 100
Est. completion date September 16, 2013
Est. primary completion date March 2013
Accepts healthy volunteers No
Gender All
Age group N/A and older
Eligibility Inclusion Criteria:

- a history of osteoarthritis, rheumatoid arthritis, or post-traumatic arthritis

- patients who have been indicated for a primary, posterior-stabilized, total knee arthroplasty

- patients have had a preoperative standing anteroposterior hip-to-ankle radiograph and standing lateral knee-to-ankle radiographs

Exclusion Criteria:

- patients with proximal tibial defects requiring either a metal or allograft augment

- inadequate radiographic studies as required by the study protocol

- if they do not receive a total knee arthroplasty, or receive a unicondylar arthroplasty

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Digital hand-held surgical navigation system
Digital hand-held surgical navigation system used for tibial component placement in total knee arthroplasty
Conventional tibial extramedullary alignment system
This is the standard of care for total knee arthroplasty.

Locations

Country Name City State
United States Hospital for Special Surgery New York New York

Sponsors (1)

Lead Sponsor Collaborator
Hospital for Special Surgery, New York

Country where clinical trial is conducted

United States, 

References & Publications (5)

Nam D, Dy CJ, Cross MB, Kang MN, Mayman DJ. Cadaveric results of an accelerometer based, extramedullary navigation system for the tibial resection in total knee arthroplasty. Knee. 2012 Oct;19(5):617-21. doi: 10.1016/j.knee.2011.09.008. Epub 2011 Oct 26. — View Citation

Nam D, Jerabek SA, Cross MB, Mayman DJ. Cadaveric analysis of an accelerometer-based portable navigation device for distal femoral cutting block alignment in total knee arthroplasty. Comput Aided Surg. 2012;17(4):205-10. doi: 10.3109/10929088.2012.689335. — View Citation

Nam D, Jerabek SA, Haughom B, Cross MB, Reinhardt KR, Mayman DJ. Radiographic analysis of a hand-held surgical navigation system for tibial resection in total knee arthroplasty. J Arthroplasty. 2011 Dec;26(8):1527-33. doi: 10.1016/j.arth.2011.01.012. Epub — View Citation

Nam D, Nawabi DH, Cross MB, Heyse TJ, Mayman DJ. Accelerometer-based computer navigation for performing the distal femoral resection in total knee arthroplasty. J Arthroplasty. 2012 Oct;27(9):1717-22. doi: 10.1016/j.arth.2012.02.007. Epub 2012 Mar 21. — View Citation

Nam D, Weeks KD, Reinhardt KR, Nawabi DH, Cross MB, Mayman DJ. Accelerometer-based, portable navigation vs imageless, large-console computer-assisted navigation in total knee arthroplasty: a comparison of radiographic results. J Arthroplasty. 2013 Feb;28( — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Postoperative Tibial Component Alignment The primary outcome will be the number of patients (percentage of patients) that met a predetermined criteria for Alignment as defined by within 2° of perpendicular to the tibial mechanical axis or 2° of a 3° posterior slope, postoperative tibial component alignment (mechanical varus/valgus, and posterior slope) as measured on postoperative standing anteroposterior hip-to-ankle radiographs, and standing, lateral knee-to-ankle radiographs, respectively. 6 weeks after surgery
Secondary Time Required to Utilize System The amount of time required to utilize conventional, tibial extramedullary alignment guides versus the KneeAlignTM system, which will be recorded intraoperatively. Minutes during surgery ( Estimated time per surgery 1 hour)
See also
  Status Clinical Trial Phase
Recruiting NCT03895489 - Effectiveness of the Journey Total Knee Arthroplasty Versus Two Standard of Care Total Knee Arthroplasty Prostheses N/A
Completed NCT03660943 - A Clinical Study to Test Efficacy and Safety of Repeat Doses of CNTX-4975-05 in Patients With Osteoarthritis Knee Pain Phase 3
Completed NCT04531969 - Comparison of Outpatient and Inpatient Spa Therapy N/A
Completed NCT02848027 - Correlating the Osteoarthritic Knee Microenvironment to Clinical Outcome After Treatment With Regenexx®SD Treatment Phase 3
Completed NCT05160246 - The Instant Effect of Kinesiology Taping in Patients With Knee OA N/A
Recruiting NCT06080763 - Biomechanics and Clinical Outcomes in Responders and Non-Responders
Completed NCT03643588 - The Comparison of HYAJOINT Plus and Hyalgan Hyaluronan Supplement for Knee Osteoarthritis Pain N/A
Active, not recruiting NCT05100225 - Efficacy and Safety Trial of PTP-001 (MOTYS) for Symptomatic Knee Osteoarthritis Phase 2
Active, not recruiting NCT04061733 - New Hydroxyethyl Cellulose Hydrogel for the Treatment of the Pain of Knee Arthrosis N/A
Completed NCT04051489 - A Novel Smartphone Application for "Smart" Knee Osteoarthritis Trials
Recruiting NCT05546541 - Epidemiology and Nutrition
Recruiting NCT05447767 - Prediction AlgoriThm for regeneraTive Medicine Approach in knEe OA: New Decision-making Process Based on Patient pRofiliNg Phase 2
Not yet recruiting NCT04448106 - Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis Phase 2
Not yet recruiting NCT03225911 - Effect of a Lateral Wedge Insole and Simple Knee Sleeve in Individuals With Knee Osteoarthritis N/A
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Completed NCT05703087 - Positive Cueing in Knee Arthroplasty. N/A
Not yet recruiting NCT06042426 - Effects of Perioperative Intravenous Dexamethasone in Clinical Outcomes After Total Knee Arthroplasty in a Hispanic Population Phase 4
Not yet recruiting NCT02865174 - Topical Tranexamic Acid and Floseal® in Total Knee Arthroplasty Phase 4
Terminated NCT02909257 - Motor-Sparing Femoral Nerve Block Dose Phase 4
Not yet recruiting NCT02826850 - Saphenous Nerve Radiofrequency for Knee Osteoarthritis Trial Phase 3