Clinical Trial Summary

Objective: The main objective of this study is to compare the (early) migration of the cemented BiMobile cup at two year post-surgery between two different cup sizes after standard optimal reaming, and consequently adjusting the cement mantle into circa 2 or 4 mm, in patients with a primary cemented total hip arthroplasty (THA). Additionally, the results of the BiMobile cup will be compared to the Avantage cup, which is placed with a standard cup size, resulting in a cement mantle of approximately 2 mm. Study design: A prospective single centre blinded randomised controlled trial. Study population: All patients who meet the criteria to undergo a cemented THA.


Clinical Trial Description

Rationale: Total hip arthroplasty (THA) is a commonly performed surgery in patients with end-stage osteoarthritis (OA) of the hip. Although it is known as a successful procedure, (recurrent) dislocation after THA is a major problem and results in a deterioration in quality of life. Dislocation after THA is the number one cause of early revision surgery. Dual-Mobility (DM) acetabular cups should provide more stability and biomechanically reduce the risk of (early) dislocation. Potential disadvantages of DM cups are increased liner wear, psoas impingement and loosening. This might result in more revision surgery at mid- and longer-term follow-up for the cemented cups. If the cemented fixation technique improves, this might diminish the disadvantages of more revisions due to loosening in cemented cups. High quality evidence guiding the best technique for cemented fixation is however lacking. The risk of implant loosening might be reduced by increasing the amount of cement used for cup fixation. It is currently unknown whether size of the implant, and thereby the amount of cement, affects stability and survival. To fill this gap in knowledge, this study will compare cup migration, as an indicator for loosening, in a new dual mobility cup (BiMobile, Waldemar Link GmbH & Co. KG, Hamburg, Germany), using a larger or smaller cup size (and thereby different amounts of cement: approximately 2mm or 4mm cement mantle). These results will also be compared with the Avantage cup (ZimmerBiomet), which is yet considered as a standard dual mobility cup in the Netherlands. Migration will be measured with Rontgen Stereophotogrammetry Analysis (RSA), which is currently the gold standard for measuring early migration and predicting long term survival. A relatively new and less intensive way to measure migration of prostheses is the use of computer tomography (CT) scans, however there is still little scientific evidence on how accurately this can be done. This study therefore also measures the accuracy with which migration is measured, between CT scans and RSA. Objective: The main objective of this study is to compare the (early) migration of the cemented BiMobile cup at two year post-surgery between two different cup sizes after standard optimal reaming, and consequently adjusting the cement mantle into circa 2 or 4 mm, in patients with a primary cemented THA. Additionally, the results of the BiMobile cup will be compared to the Avantage cup, which is placed with a standard cup size, resulting in a cement mantle of approximately 2 mm. Study design: A prospective single centre blinded randomised controlled trial. Study population: At the outpatient clinic of OLVG, all patients who meet the criteria to undergo a cemented THA will be screened for the in- and exclusion criteria. Intervention: Group A: 25 patients will receive a cemented THA with a BiMobile dual mobility cup, in a standard size after optimal reaming, resulting in a cement mantle of approximately 2mm. Group B: 25 patients will receive a cemented THA with a BiMobile dual mobility cup, in one size smaller than standard after optimal reaming, resulting in a cement mantle of approximately 4mm. Group C: 25 patients will receive a cemented THA with an Avantage dual mobility cup, in a standard size after optimal reaming, resulting in a cement mantle of approximately 2mm. Main study parameters/endpoints: Migration of the acetabular cup at two year postoperative, measured with RSA and CT. RSA x-rays will be collected at discharge, 6 weeks, 6 months, 1 year and 2 years after surgery. CT scans will be collected at discharge and 2 years after surgery. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04049279
Study type Interventional
Source JointResearch
Contact Loes van Beers, MSc
Phone +31(0)20-5993653
Email l.w.a.h.vanbeers@olvg.nl
Status Recruiting
Phase N/A
Start date January 1, 2019
Completion date March 31, 2029

See also
  Status Clinical Trial Phase
Active, not recruiting NCT05773261 - Clinical Investigation Comparing Two Different Ultra-porous Coated Surfaces of Uncemented Cups N/A
Recruiting NCT05223777 - KINCISEā„¢ Surgical Automated System in Total Hip Arthroplasty (THA) N/A
Recruiting NCT04731077 - Avenir Complete Post-Market Clinical Follow-Up Study N/A
Not yet recruiting NCT04448106 - Autologous Adipose Tissue-Derived Mesenchymal Stem Cells (AdMSCs) for Osteoarthritis Phase 2
Completed NCT05070871 - A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women N/A
Not yet recruiting NCT06162195 - The ACTIVE Trial: A Prospective Randomised Control Trial Of The H1 Implant Versus Total Hip Replacement N/A
Withdrawn NCT02743208 - Evaluation of a Short Femoral Stem in Total Hip Arthroplasty N/A
Completed NCT02944448 - A Study Evaluating Pain Relief and Safety of Orally Administered CR845 in Patients With Osteoarthritis of Hip or Knee Phase 2
Active, not recruiting NCT02229279 - Evaluation of Teleconsulting on Rehabilitation After Hip and Knee Surgical Procedures N/A
Active, not recruiting NCT02851992 - A Prospective Study to Evaluate Long-term Clinical Outcomes of the GTS Cementless Femoral Stem N/A
Completed NCT01618708 - A Study of the Safety and Effectiveness of Synvisc-One® (Hylan G-F 20) in Patients With Primary Osteoarthritis of the Hip N/A
Completed NCT01700933 - Dose-response: Exercise Therapy on Hip Osteoarthritis N/A
Completed NCT01214954 - Early Rehabilitation After Total Hip Replacement N/A
Active, not recruiting NCT00294424 - Study on Costs and Effects of Waiting Time in Total Hip and Knee Replacements N/A
Terminated NCT00588861 - Total Hip Replacement With the Answer® Hip Stem and Ranawat/Burnstein® Shell Using Simplex® or Palacos® Bone Cement N/A
Withdrawn NCT05054595 - Audio-Recorded vs. Nurse-Led Brief Mindfulness-Based Intervention N/A
Terminated NCT00973141 - A Dose-ranging Study of the Safety and Effectiveness of JNJ-42160443 as add-on Treatment in Patients With Osteoarthritis-related Pain Phase 2
Recruiting NCT05014113 - H-28 DELTA ST-C and Minima Retrospective Study.
Completed NCT01066936 - Mini Stem DEXA (Dual Energy X-ray Absorptiometry)
Recruiting NCT06185036 - Histological Validation of dGEMRIC Indices as a Quantitative Biomarker for Cartilage Damage in the Hip Joint