Study type | Interventional |
The routine use of a styletted endotracheal tube during videolaryngoscopy is advocated by some manufacturers, but styletted endotracheal tube can elicit rare but potentially serious complications. We compared the intubation time and success rate whether or not use of stylet for endotracheal intubation with McGrath videolaryngoscope.
Status | Completed |
Enrollment | 140 |
Est. completion date | May 2016 |
Est. primary completion date | May 2016 |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 19 Years to 70 Years |
Eligibility |
Inclusion Criteria: - American Society of Anesthesiologists physical status I or II undergoing orotracheal intubation for elective surgery Exclusion Criteria: - cervical spine injury - rapid sequence induction - body mass index> 35 kg/m2 - airway pathology |
Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Subject), Primary Purpose: Prevention
Country | Name | City | State |
---|---|---|---|
Korea, Republic of | Ajou University Hospital | Suwon | Gyeongki-do |
Korea, Republic of | Ajou University Hospital | Suwon |
Lead Sponsor | Collaborator |
---|---|
Ajou University School of Medicine |
Korea, Republic of,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | intubation time | time the blade passed the lips until endtidal CO2 was detected | 2 min after rocuronium injection | Yes |
Status | Clinical Trial | Phase | |
---|---|---|---|
Withdrawn |
NCT04858906 -
Neutral Position Facilitates Orotracheal Intubation With Videolaryngoscopes
|
N/A | |
Completed |
NCT04857190 -
Parker Flex-it Stylet Versus Malleable Stylet in Orotracheal Intubation Using a Fiber-optic Laryngoscope
|
N/A | |
Completed |
NCT00631176 -
"Just-In-Time Training" in Pediatric Airway Management
|
N/A | |
Completed |
NCT01908218 -
The Reliability and Validity of the Upper Lip Bite Test to Predict Difficult Laryngoscopy in Korean
|
N/A | |
Completed |
NCT03743831 -
Comparison of Haemodynamic Effects During Orotracheal Intubation, by Direct or Indirect Laryngoscopy With Airtraq
|
N/A |