View clinical trials related to Ocular Hypertension.
Filter by:A randomized, double-blind, parallel-group, two-arm, multiple dose, multicenter, clinical endpoint bioequivalence study
The CATS Tonometer prism clinical study is intended to determine repeatability of intraocular pressure measurement in human corneas which have undergone a LASIK procedure when compared to a standard Goldmann prism, validating the human LASIK eye findings comparing CATS Tonometer and Goldmann prisms to intracameral pressure in cadaver eyes.
The purpose of this study was to explore the efficacy and safety of the weekly intraocular pressure change of the TFC-003 group and the dorzolamid/timolol combination group in patients with primary open-angle glaucoma or ocular hypertension.
Effectiveness of anterior chamber drainage on the structure of the anterior chamber, the position of the intraocular lens and the shape of the corneal incision in the early stage of cataract surgery with high intraocular pressure
This is a randomized control trial comparing the effects of subconjunctival triamcinolone administration during surgery to topical prednisolone drops on the development of post-operative inflammation and macular edema in manual small incision cataract surgery.
This is a phase 3 study to confirm the efficacy in reduction of intraocular pressure and safety of PHP-201 ophthalmic solution in patients with primary open-angle glaucoma or ocular hypertension.
This is a prospective, multi-centre, cross sectional observational study to determine the prevalence of ocular surface disease (OSD) in glaucoma patients, nationwide. The study also analyses sub group of OSD prevalence, stratified according to the treatment types (i.e. preserved, preservative-free, and combination of preservative-free and preserved eyedrops), and illustrates the patient perspective on OSD.
While elevated intraocular pressure (IOP) is no longer part of the definition of glaucoma it remains the sole proven modifiable risk factor for the onset and progression of glaucoma. IOP is known to vary with the time of day as well as with daily activities. The importance of the nycthemeral IOP pattern for successful management of glaucoma has been well documented, especially for patients who experience visual loss despite apparently normal and/or controlled IOP during office hours. The current way of assessing nycthemeral IOP fluctuation is to perform repeated discrete tonometry measurements, once per hour in the best cases. Since its development in the 50s, Goldmann applanation tonometry (GAT) has remained the gold standard method for measuring IOP, despite its limitations. However, tonometry may be an imperfect method for measuring changes in IOP because it allows only snapshot and non-continuous measurements, it is not physiologic and disturbs the sleep architecture. There have been many efforts in the past decades to search for an ambulatory and frequent method to monitor IOP for 24 hours. In this context, Sensimed AG has recently developed a sensing contact lens-based device intended to measure IOP over 24 hours, the Goldfish (GF). First-in-man data obtained with this device showed agreements between IOP measured by GF and values obtained by standard tonometry in the same eye, comparable to literature results for routinely used tonometry devices. However, this pilot study included 9 subjects only with improvable safety, tolerability and efficacy profiles. The main goal of this study is to assess IOP measurements with the GF and compare the values with those obtained by standard tonometry in patients with open angle glaucoma (OAG) and ocular hypertension (OHT).
The purpose of this study is to evaluate efficacy and safety of CKD-351.
Study the change of retrofoveolar choroidal thickness measured by optical coherence tomography during aerobic exercise inducing an increase in systolic blood pressure in healthy subjects.Ten healthy participants will perform an exercise (riding a bicycle ergometer) and will be examined with EDI-OCT. Each participant will be scanned before exercise, during the exercise and afterwards at 0 and 5 min. Each OCT measurement will be coupled to the arterial blood pressure evaluation.