Clinical Trials Logo

Clinical Trial Summary

This clinical study has been planned to evaluate the safety and effectiveness of the SUPRACR presbyopic excimer laser treatment algorithm for myopic eyes developed for applying to the cornea of the human eye in a single center.

The developed software algorithm uses the subjective refraction of the eye to create a treatment for the distance vision correction. This part of the treatment does not show any difference to a regular aspheric LASIK treatment for myopic cases.

In addition to the treatment for the distance vision an additional central ablation component will be added to address the near vision.

The study design is applied as a single center unilateral eye safety and effectiveness study of the SUPRACOR presbyopic algorithm for myopia with a 3 months postoperative follow up.


Clinical Trial Description

Presbyopia is an age-related progressive decrease in the ability to bring near objects to clear focus. It is attributed to changes in the accommodative apparatus in the visual system which includes the ciliary muscle and crystalline lens. Current Presbyopia management includes bifocal or multifocal corrections in spectacles or contact lenses that provide good focus over a range of object distances.

Current LASIK refractive surgery algorithms using Excimer laser are a safe, effective, and precise way to treat ametropia in eyes with regular corneas. The LASIK procedure uses a microkeratome to create a lamellar resection of the cornea at an intended depth ranging from 90 to 160 microns. The microkeratome is designed to maintain a "hinge" of tissue so that a flap of corneal epithelium and superficial stroma can be lifted to expose deeper stromal tissue while remaining attached to the cornea. The ablative energy of the excimer laser is then applied directly on the exposed corneal stroma to remove the required amount of tissue for a given refractive error. The amount of corneal tissue to be removed is determined by the magnitude of refractive correction and treatment area (optic zone). Once the laser ablation is completed, the flap is repositioned over the residual stromal bed.

The presbyopic treatment consists of a standard aspheric treatment for distance vision and the so called SUPRACOR addition to correct near vision.

The SUPRACOR addition provides a multifocal ablation with a central near addition with an aberration controlled transition zone towards the periphery, thereby allowing good focus over a range of object distances. This approach showed good near visual performance in hyperopic eyes (see also section 2.1).

The SUPRACOR presbyopic treatment algorithm subject to this study has been specifically developed to prospectively generate a treatment file for the Technolas 217z100 laser that will provide Presbyopia correction among eyes with primary myopia or myopic astigmatism (distance correction). ;


Study Design

Allocation: Non-Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT01404884
Study type Interventional
Source Technolas Perfect Vision GmbH
Contact
Status Active, not recruiting
Phase Phase 3
Start date June 2011
Completion date April 2016

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04923841 - Myopia Control Using Bright Light Therapy, Myopic Defocus and Atropine N/A
Active, not recruiting NCT04080128 - Examination of Myopia Progression and Soft Bifocal Contact Lens Myopia Control N/A
Active, not recruiting NCT05275959 - Beijing (Peking)---Myopia and Obesity Comorbidity Intervention (BMOCI) N/A
Completed NCT04604405 - Effects of 650nm Low Energy Light on Human Retina and Choroid Microcirculation N/A
Recruiting NCT05594719 - The Effect of Sun-like Spectrum With Different Spectrum Composition on Retinal Blood Flow N/A
Completed NCT05594732 - The Effects of Different Outdoor Light Exposure Modes on Retinal Blood Flow N/A
Completed NCT04492397 - Comparing The Performance Of Two Different Daily Disposable Lenses (MIKI) N/A
Completed NCT04536571 - Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses N/A
Completed NCT06046209 - Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens N/A
Recruiting NCT06344572 - Pivotal Study of SAT-001 in Treatment of Pediatric Patient With Myopia Phase 3
Recruiting NCT05611294 - Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction N/A
Completed NCT05656885 - Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses N/A
Active, not recruiting NCT05534022 - Clinical Evaluation of a Myopia Control Lens in Slowing Myopia Progression. N/A
Completed NCT03934788 - the Clinical Performance of the Oxysoft Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT03701516 - Clinical Evaluation of Etafilcon A Contact Lenses Using a Novel Molding Process 2 N/A
Completed NCT05538754 - Post-Market Evaluation of the EVO ICL N/A
Completed NCT03139201 - Clinical Performance of the OxyAqua Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT02555722 - Evaluation of the CooperVision, Inc. Fanfilcon A and Enfilcon A Daily Wear Contact Lenses When Used for Frequent Replacement for up to One (1) Month of Daily Wear N/A
Not yet recruiting NCT06009458 - Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear N/A
Recruiting NCT05548478 - Corneal Endothelial Cell Injury Induced by Mitomycin-C N/A