Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT02112968
Other study ID # 1302
Secondary ID
Status Not yet recruiting
Phase Phase 4
First received April 10, 2014
Last updated November 19, 2014
Start date December 2014
Est. completion date May 2017

Study information

Verified date November 2014
Source Technolas Perfect Vision GmbH
Contact Melanie Doerner
Phone +49 89 94004130
Email melanie.doerner@bausch.com
Is FDA regulated No
Health authority Czech: Ethics Committee
Study type Interventional

Clinical Trial Summary

This clinical study has been planned to evaluate the safety and effectiveness of common treatment algorithms using 500 Hz laser repetition rate for the correction of Ammetropia and Presbyopia


Description:

This clinical study has been planned to evaluate the safety and effectiveness of the excimer laser treatment algorithms Proscan, Zyoptix and Supracor of the 500 Hz laser system for ametropia and/or presbyopia when performed on the cornea of virgin eyes.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 97
Est. completion date May 2017
Est. primary completion date February 2016
Accepts healthy volunteers No
Gender Both
Age group 18 Years to 85 Years
Eligibility Inclusion Criteria:

- Subjects have to be at least 18 years of age.

- Subjects have to be able to read, understand, and sign a statement of Informed Consent (be given a copy of the signed Informed Consent Form (ICF).

- Subjects have to be willing and able to return for scheduled follow-up examinations for up to 6 respectively 12 months after surgery.

- For Proscan and Zyoptix Treatments the myopic subjects require a sphere between -0.5 D up to a maximum sphere of -10.0 D. If the patient has a refractive astigmatism to be treated, this must be between -0.5 D up to -4.0 D (not corneal astigmatism) as expressed in spectacle minus cylinder form (by manifest subjective refraction). Overall the SE for myopes must be no more than -12.0 D.

- The Hyperopic subjects require a sphere between +0.5 D up to a maximum sphere of +4.0 D. If the patient has a refractive astigmatism to be treated, this must be between +0.5 D up to +4.0 D (not corneal astigmatism) as expressed in spectacle plus cylinder form (by manifest subjective refraction). Overall the SE for hyperopes must be no more than +6.0 D.

- Subjects who are contact lens wearers must have gas permeable lenses discontinued for at least 3 weeks and soft lenses discontinued for at least 1 week prior to the pre-operative evaluation in the eye to be treated.

- Corneal topography should be qualified.

- Subjects who are contact lens wearers must have two (2) central keratometry readings and two (2) manifest subjective refractions taken pre-operatively at least one week apart. The refraction values must not differ by more than 0.50 D as defined by manifest refraction spherical equivalent (MRSE). The keratometry values must not differ from the previous values by more than 0.50 D in either meridian.

- High contrast, manifest, best spectacle-corrected distance visual acuity correctable binocular to at least 1.0 (Snellen 20/20 or 6/6) and monocular to at least 0.8 (Snel-len 20/25 or 6/7.5). In case of a monocular surgery the eye which should not be treated must have a best corrected distance visual acuity of at least 0.8 (Snellen 20/25 or 6/7.5).

- For treatments with the SUPRACOR presbyopic algorithm, subjects have to be at least 45 years old and no more than 85 years.

- For treatments with the SUPRACOR presbyopic algorithm, subjects must have presbyopia as determined by an age-related need for optical aid (> +1.50 D) for reading with their best distance correction and been screened successfully for acceptance of the SUPRACOR simulation.

- For treatments with the SUPRACOR presbyopic algorithm, subjects must been screened successfully for acceptance of the SUPRACOR simulation

- For treatments with the SUPRACOR presbyopic algorithm, Myopic subjects must have up to -7.0 diopters (D) of absolute spherical myopia (not spherical equivalent), with up to -4.0 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction. The spherical equivalent and must be no more than -9.0 D.

- Hyperopic subjects must have up to +4 diopters (D) of absolute spherical hyperopia (not spherical equivalent), with up to +2.5 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction in both eyes. The spherical equivalent must be no more than +5.25 D.

- Mesopic pupil size measured with the Zywave II WaveFront Aberrometer must be < 7.0 mm and photopic pupil size measured with the Orbscan II/ IIz must be > 2.9 mm.

- For treatments with the Zyoptix algorithm, the high-order-aberration must be at least 0.35µm.

Exclusion Criteria:

- Subjects for whom the combination of their baseline corneal thickness and the planned operative parameters for the LASIK procedure would result in less than 250 microns of remaining posterior corneal thickness below the flap postoperatively.

- Hyperopic eyes for which the baseline manifest subjective refraction exhibits a difference of greater than ± 0.75 D in sphere power, or a difference of greater than ± 0.50 D in cylinder power, or a difference in cylinder axis of more than 15 degrees compared to the baseline cycloplegic subjective refraction. For manifest cylinder of less than ±0.75 D, the difference in cylinder axis would not be taken into consideration.

- Any subject who is going to be co-managed by an ophthalmologist or optometrist who were not approved as a Technolas Perfect Vision Investigator.

- Subjects with anterior segment pathology, including dry eye syndrome and cataracts, which in the Investigator's opinion would interfere with best spectacle-corrected visual acuity or a successful treatment.

- Subjects with evidence of retinal vascular disease.

- Subjects with any residual, recurrent, or active ocular disease, or corneal abnormality that in the Investigator's opinion would interfere with BSCVA or a successful treatment.

- Subjects with signs of keratoconus.

- Subjects with unstable central keratometry readings with irregular mires.

- Subjects who had previous intraocular or corneal surgery of any kind, including any type of Excimer laser surgery for either refractive or therapeutic purposes.

- Subjects who have a history of Herpes simplex or Herpes zoster keratitis.

- Subject who have a history of glaucoma or glaucoma suspect.

- Subjects with corneal edema, or increased IOP > 22mmHg.

- Subjects at risk for angle closure.

- Subjects immunocompromised or carrying diagnosis of connective tissue disease, clinically significant atopic disease, diabetes, autoimmune diseases and other acute or chronic illnesses that will increase the risk to the subject or confound the outcomes of this study.

- Subject taking systemic medications likely to affect wound healing such as corticosteroids or antimetabolites.

- Subjects who are known to be pregnant, lactating, or who plans to become pregnant over the course of the study.

- Subjects with known sensitivity to medications used for standard LASIK.

- Subjects participating in any other ophthalmic clinical trials during this clinical study.

- Subjects with an ocular muscle disorder including a strabismus or nystagmus, or other disorders affecting fixation.

- Subjects with cognitive impairments or other vulnerable persons.

- Subjects with anterior or posterior synechiae.

Study Design

Allocation: Non-Randomized, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Procedure:
Proscan
One device (500 Hz Excimer Laser) with three interventions (Proscan, Zyoptix and Supracor as algorithms)
Zyoptix
One device (500 Hz Excimer Laser) with three interventions (Proscan, Zyoptix and Supracor as algorithms)
Supracor
One device (500 Hz Excimer Laser) with three interventions (Proscan, Zyoptix and Supracor as algorithms)

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Technolas Perfect Vision GmbH

Outcome

Type Measure Description Time frame Safety issue
Primary For Proscan and Zyoptix: - The percentage of treated eyes within +/- 0.50D of target refraction. For Supracor: - The percentage of treated eyes with a best corrected high contrast distance VA of Snellen 20/25 (6/7.5 or 0.1 logMAR) or better Myopia: 6 months, Hyperopia 12 months No
See also
  Status Clinical Trial Phase
Active, not recruiting NCT04923841 - Myopia Control Using Bright Light Therapy, Myopic Defocus and Atropine N/A
Active, not recruiting NCT04080128 - Examination of Myopia Progression and Soft Bifocal Contact Lens Myopia Control N/A
Active, not recruiting NCT05275959 - Beijing (Peking)---Myopia and Obesity Comorbidity Intervention (BMOCI) N/A
Completed NCT04604405 - Effects of 650nm Low Energy Light on Human Retina and Choroid Microcirculation N/A
Recruiting NCT05594719 - The Effect of Sun-like Spectrum With Different Spectrum Composition on Retinal Blood Flow N/A
Completed NCT05594732 - The Effects of Different Outdoor Light Exposure Modes on Retinal Blood Flow N/A
Completed NCT04492397 - Comparing The Performance Of Two Different Daily Disposable Lenses (MIKI) N/A
Completed NCT04536571 - Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses N/A
Completed NCT06046209 - Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens N/A
Recruiting NCT06344572 - Pivotal Study of SAT-001 in Treatment of Pediatric Patient With Myopia Phase 3
Recruiting NCT05611294 - Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction N/A
Completed NCT05656885 - Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses N/A
Active, not recruiting NCT05534022 - Clinical Evaluation of a Myopia Control Lens in Slowing Myopia Progression. N/A
Completed NCT03934788 - the Clinical Performance of the Oxysoft Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT03701516 - Clinical Evaluation of Etafilcon A Contact Lenses Using a Novel Molding Process 2 N/A
Completed NCT05538754 - Post-Market Evaluation of the EVO ICL N/A
Completed NCT03139201 - Clinical Performance of the OxyAqua Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT02555722 - Evaluation of the CooperVision, Inc. Fanfilcon A and Enfilcon A Daily Wear Contact Lenses When Used for Frequent Replacement for up to One (1) Month of Daily Wear N/A
Not yet recruiting NCT06009458 - Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear N/A
Recruiting NCT05548478 - Corneal Endothelial Cell Injury Induced by Mitomycin-C N/A