Study information

Verified date September 2016
Source Columbia University
Contact n/a
Is FDA regulated No
Health authority United States: Institutional Review Board
Study type Observational

Clinical Trial Summary

The proposed research project will continue the application and development of a new method (biomagnetic susceptometry) that measures magnetic fields to determine how much iron is in the liver. The amount of iron in the liver is the best indicator of the amount of iron in the whole body. Measuring the amount of iron in the body is important because either too much (iron overload) or too little iron (iron deficiency) can be harmful. At present, the most reliable way to measure the amount of iron in the liver is to remove a sample of the liver by biopsy, either by surgery or by using a needle which pierces the skin and liver. Iron stored in the liver can be magnetized to a small degree when placed in a magnetic field. In patients with iron overload, the investigators previous studies have shown that magnetic measurements of liver iron in patients with iron overload are quantitatively equivalent to biochemical determinations on tissue obtained by biopsy. In the past the investigators have developed a device to measure the amount of magnetization, which was called a SQUID (Superconducting QUantum Interference Device) susceptometer. This device was validated and in use for over 20 years. The safety, ease, rapidity and comfort of magnetic measurements make frequent, serial studies technically feasible and practically acceptable to patients. The investigators have now developed a new susceptometer, which uses very similar technology to the SQUID, but the investigators believe is more accurate and precise. This study aims to validate this new instrument. The investigators will do prospective, serial studies of the diagnosis and management of patients with iron overload, including thalassemia major (Cooley's anemia), sickle cell disease, aplastic anemia, myelodysplasia, hereditary hemochromatosis, and other disorders. Funding Source - FDA OOPD.


Description:

This project will validate our new high-transition-temperature (high-Tc; operating at 77°K, cooled by liquid nitrogen) superconducting magnetic susceptometer as the most clinically effective means for monitoring iron overload in patients who require chronic red blood cell transfusion. Transfusional iron overload is an orphan disease that develops in patients who require regular blood transfusions for treatment of a variety of refractory anemias that are themselves orphan disorders, including sickle-cell disease, thalassemia major (Cooley's anemia), Diamond-Blackfan anemia, aplastic anemia, pure red cell aplasia, hypoplastic and myelodysplastic disorders. In the United States, the number of anemic patients with transfusional iron overload is estimated to be less than 50,000. Without iron-chelating therapy, potentially lethal amounts of iron accumulate in these patients. Because the body lacks an effective means to eliminate excess iron, the iron contained in transfused red cells is progressively deposited in the liver, heart, pancreas and other organs. Cirrhosis, heart failure, diabetes and other disorders develop. Treatment with a chelating agent capable of sequestering iron and permitting its excretion from the body provides a means of managing transfusional iron overload that can prolong survival and avert or ameliorate iron-induced organ damage. Two iron-chelating agents are now approved for use in the U.S. for the treatment of transfusional iron overload: (1) deferoxamine B (Desferal®), a parenteral agent in use for almost four decades, and (ii) deferasirox (Exjade®), an orally administered agent introduced in 2005. With both chelators, optimal management of patients requires careful monitoring of body iron to prevent iron-induced toxicity while avoiding adverse effects of excessive chelator administration. Our laboratories originally proposed that storage iron (ferritin and hemosiderin) could be non-invasively assessed in vivo by measurement of magnetic susceptibility. We subsequently developed low-transition-temperature (low-Tc; operating at 4°K, cooled by liquid helium) superconducting quantum interference device (SQUID) susceptometry as a clinical method for quantitation of hepatic iron stores. The transition temperature is the temperature at which the electrical resistance of a superconducting material drops to zero. The safety, ease, rapidity and comfort of magnetic measurements have made frequent, serial investigations technically feasible and practically acceptable to patients. Susceptometry permits accurate, direct, reliable, and repeated measurements of hepatic iron stores. Despite these advantages, the cost (about $1,000,000 per device), instrumental complexity and need for liquid-helium cooling of the low-Tc susceptometers restricted clinical adoption of the method. Worldwide, only four low-Tc susceptometers have been used clinically (in New York, Oakland, Hamburg and Turin). Recently, with the support of a Bioengineering Research Partnership Grant (R01 DK057209), we have made a series of technological breakthroughs and instrumental innovations that have made possible replacement, redesign and refinement of the elements of the low-Tc susceptometer, operating at 4°K in liquid helium, with components able to function at 77°K in liquid nitrogen. This new high-Tc susceptometer, the first medical device utilizing the phenomenon of high-temperature superconductivity, is an inexpensive instrument that can easily be used in a hospital environment. These Phase 2 clinical studies are designed to test the hypothesis that measurements of hepatic iron stores with our new high-Tc susceptometer are clinically superior to all other available methods and to supply essential data needed for FDA approval of the medical device. The proposed project has three specific aims:

1. to calibrate the high-Tc susceptometer with the results of biochemical analysis of tissue from liver explants from adult and pediatric patients undergoing liver transplantation and from clinically indicated liver biopsy; and

2. to prospectively validate the high-Tc susceptometer using the results of biochemical analysis of tissue from liver explants from adult and pediatric patients undergoing liver transplantation and from clinically indicated liver biopsy; and

3. to prospectively compare measurements of hepatic iron concentration by the high-Tc susceptometer with (i) estimates derived from liver magnetic resonance imaging (MRI) relaxation rates (R2, R2*, signal intensity ratios), (ii) with determinations of serum ferritin, and (iii) with histopathological examination, using biochemical analysis of liver storage iron concentrations as the reference standard.

FDA approval of an affordable, readily usable instrument for the non-invasive measurement of hepatic iron stores would lead to major advances in the management of patients with transfusional iron overload that would find immediate and widespread clinical use both in the U.S. and worldwide.


Recruitment information / eligibility

Status Completed
Enrollment 99
Est. completion date May 2016
Est. primary completion date October 2015
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Both
Age group 5 Years to 80 Years
Eligibility Inclusion Criteria:

- being an adult male, nonpregnant female or child who is scheduled for liver transplantation, has transfusional iron overload or is healthy with no known disorder affecting body iron stores,

- being of sufficient size for the susceptometer (about 15 kg body weight),

- being able to lie quietly during the measurement procedure (about 5 to 10 minutes),

- being either able to give fully informed consent or, if a minor, with a parent or legal guardian who is able to give fully informed consent for participation of the minor.

Exclusion Criteria:

- any form of magnetic contamination or electrical device which cannot be removed for the magnetic measurement procedure, including jewelry, pacemakers, artificial joints, metal staples, indwelling catheters with metallic components, dental braces or other magnetic objects;

- obesity, ascites or other conditions in which the liver to surface distance exceeds 25 mm;

- pregnancy, treatment for mental illness, imprisonment, institutionalization, or any condition that impairs ability to provide fully informed consent.

Study Design

Time Perspective: Prospective


Intervention

Device:
Hepatic biomagnetic susceptibility measurement
Subjects will first have an ultrasound study to determine the location of the liver and measure the distance from skin surface to the liver. Subjects will then be examined with the high Tc susceptometer to determine the amount of iron in the liver. The entire procedure will usually take one-half hour or less.

Locations

Country Name City State
United States Columbia University Medical Center New York New York

Sponsors (1)

Lead Sponsor Collaborator
Columbia University

Country where clinical trial is conducted

United States, 

References & Publications (2)

Farrell DE, Allen CJ, Whilden MW, Kidane TK, Baig TN, Tripp JH, Brown RW, Sheth A, Brittenham GM. A new instrument designed to measure the magnetic susceptibility of human liver tissue in vivo. IEEE Trans Magnetics 2007;43:3543-3554.

Farrell DE, Allen CJ, Whilden MW, Tripp JH, Usoskin A, Sheth A, Brittenham GM. Magnetic measurement of liver iron stores: engineering aspects of a new scanning susceptometer based on high temperature superconductivity. IEEE Trans Magnetics 2007; 43:4030-4036.

Outcome

Type Measure Description Time frame Safety issue
Primary Hepatic non-heme iron concentration determined by biomagnetic susceptometry The primary study analysis will be a comparison of the results of measurements of the hepatic storage iron concentration by biomagnetic susceptometry with the results of biochemical analysis of the storage iron concentration in liver tissue. 2 years No
Secondary Serum ferritin concentration A secondary study analysis will be a comparison of the results of measurements of the hepatic storage iron concentration by biomagnetic susceptometry with the results of measurements of the serum ferritin concentration. 2 years No
See also
  Status Clinical Trial Phase
Recruiting NCT05400122 - Natural Killer (NK) Cells in Combination With Interleukin-2 (IL-2) and Transforming Growth Factor Beta (TGFbeta) Receptor I Inhibitor Vactosertib in Cancer Phase 1
Terminated NCT04313881 - Magrolimab + Azacitidine Versus Azacitidine + Placebo in Untreated Participants With Myelodysplastic Syndrome (MDS) Phase 3
Recruiting NCT05088356 - Reduced Intensity Allogeneic HCT in Advanced Hematologic Malignancies w/T-Cell Depleted Graft Phase 1
Recruiting NCT04003220 - Idiopathic Chronic Thrombocytopenia of Undetermined Significance : Pathogenesis and Biomarker
Completed NCT02916979 - Myeloid-Derived Suppressor Cells and Checkpoint Immune Regulators' Expression in Allogeneic SCT Using FluBuATG Phase 1
Active, not recruiting NCT03755414 - Study of Itacitinib for the Prophylaxis of Graft-Versus-Host Disease and Cytokine Release Syndrome After T-cell Replete Haploidentical Peripheral Blood Hematopoietic Cell Transplantation Phase 1
Completed NCT00003270 - Chemotherapy, Radiation Therapy, and Umbilical Cord Blood Transplantation in Treating Patients With Hematologic Cancer Phase 2
Recruiting NCT04904588 - HLA-Mismatched Unrelated Donor Hematopoietic Cell Transplantation With Post-Transplantation Cyclophosphamide Phase 2
Terminated NCT04866056 - Jaktinib and Azacitidine In Treating Patients With MDS With MF or MDS/MPN With MF. Phase 1/Phase 2
Recruiting NCT04701229 - Haploinsufficiency of the RBM22 and SLU7 Genes in Del(5q) Myelodysplastic Syndromes
Suspended NCT04485065 - Safety and Efficacy of IBI188 With Azacitidine in Subjects With Newly Diagnosed Higher Risk MDS Phase 1
Recruiting NCT04174547 - An European Platform for Translational Research in Myelodysplastic Syndromes
Enrolling by invitation NCT04093570 - A Study for Participants Who Participated in Prior Clinical Studies of ASTX727 (Standard Dose), With a Food Effect Substudy at Select Study Centers Phase 2
Completed NCT02508870 - A Study of Atezolizumab Administered Alone or in Combination With Azacitidine in Participants With Myelodysplastic Syndromes Phase 1
Completed NCT04543305 - A Study of PRT1419 in Patients With Relapsed/Refractory Hematologic Malignancies Phase 1
Recruiting NCT05384691 - Efficacy of Luspatercept in ESA-naive LR-MDS Patients With or Without Ring Sideroblasts Who do Not Require Transfusions Phase 2
Recruiting NCT05365035 - A Phase II Study of Cladribine and Low Dose Cytarabine in Combination With Venetoclax, Alternating With Azacitidine and Venetoclax, in Patients With Higher-risk Myeloproliferative Chronic Myelomonocytic Leukemia or Higher-risk Myelodysplastic Syndromes With Excess Blasts Phase 2
Recruiting NCT06008405 - Clinical Trial Evaluating the Safety of the TQB2928 Injection Combination Therapy Phase 1
Not yet recruiting NCT05969821 - Clonal Hematopoiesis of Immunological Significance
Withdrawn NCT05170828 - Cryopreserved MMUD BM With PTCy for Hematologic Malignancies Phase 1