Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT06113354
Other study ID # 202302
Secondary ID
Status Not yet recruiting
Phase N/A
First received
Last updated
Start date December 2023
Est. completion date December 2029

Study information

Verified date November 2023
Source Polares Medical SA
Contact Stephen Kao
Phone +1 650 776 8433
Email skao@polaresmedical.com
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

An early feasibility study to evaluate the safety and feasibility of the MRace Implant and Delivery System to treat severe mitral regurgitation and to gather preliminary data on its performance thereby providing guidance for future clinical development. The study is a single-arm registry with the last follow-up visit at 5 years post-intervention. The study will enroll up to 10 patients at one (1) center in Brazil.


Description:

Percutaneous approaches to treat MR promise to provide a sufficient reduction in MR without the risks typically associated with open heart surgery. Furthermore there is an unmet clinical need for patients with severe MR who are refused or denied surgery due to high risk. Percutaneous therapy provides a novel alternative treatment option for these patients with the aim of reducing morbidity and mortality over and above current medical therapy. The Polares Medical MRace Implant and Delivery System is a catheter-based technology designed to permanently implant a prosthesis using a transvenous / transseptal approach to augment the posterior mitral valve leaflet and improve coaptation with the anterior leaflet. Approved edge-to-edge repair has already been shown to be a viable alternative for high risk MR patients. However treatment with these devices is limited to specific anatomies and often requires multiple devices which increases clinical risk, adds to procedural time, and can result in residual MR. The MRace Implant and Delivery System has been designed to overcome and mitigate some of these shortfalls.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 10
Est. completion date December 2029
Est. primary completion date March 2025
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. 18 years of age or older 2. Greater than moderate mitral regurgitation (Grade 3+ or higher) as confirmed by transesophageal echocardiography (TEE) within 90 days prior to study procedure 3. Patient must present with an STS Score less than 10% 4. High surgical risk for conventional mitral repair or replacement due to morphological criteria (e.g. leaflet or annulus calcifications), but operable, as assessed by the local heart team comprised of a cardiac surgeon experienced in mitral valve surgery and a cardiologist experienced in treating mitral valve disease and heart failure 5. New York Heart Association (NYHA) Functional Class III or IV 6. Patient willing to participate in study and provide signed IRB/EC-approved informed consent 7. Treating physician and patient agree that patient is able to return for all required post-procedure follow-up visits Exclusion Criteria: 1. Severe tricuspid regurgitation 2. Severe aortic stenosis or insufficiency 3. Severe mitral annulus calcification 4. Diseased mitral anterior leaflet such as flail / prolapse/ heavy calcification 5. Implanted vena cava filter 6. Femoral veins with severe angulation and calcification 7. Contraindication for transesophageal echocardiography (TEE) or MDCT scan 8. Active infection or endocarditis 9. Previous mitral valve surgery 10. Prior orthotopic heart transplantation 11. Pulmonary artery systolic hypertension > 70mmHg 12. Evidence of intra-cardiac, inferior vena cava (IVC) or femoral venous thrombus 13. Left ventricular ejection fraction (LVEF) < 30% 14. Implant or revision of any pacing device < 30 days prior to intervention 15. Symptomatic coronary artery disease treated < 30 days prior to study procedure 16. Myocardial infarction requiring intervention < 30 days prior to study procedure 17. Infiltrative cardiomyopathies (e.g., amyloidosis, hemochromatosis, sarcoidosis), hypertrophic or restrictive cardiomyopathies, and constrictive pericarditis 18. Active peptic ulcer or upper gastrointestinal bleeding < 90 days prior to study procedure 19. Stroke < 180 days prior to study procedure 20. Severe renal insufficiency (creatinine > 3.0 mg/dL) or patient requiring dialysis 21. Cardiogenic shock at time of enrolment 22. Hemodynamic instability requiring inotropic support or mechanical heart assistance 23. Concurrent medical condition with a life expectancy of less than 2 years 24. Pregnancy at time of enrolment 25. History of bleeding diathesis or coagulopathy or leukopenia (WBC < 3,000 mcL) or acute anemia (Hb < 9 g/dL) or thrombocytopenia (platelets < 50,000 cells mcL) 26. Known hypersensitivity or contraindication to aspirin, heparin, ticlopidine or clopidogrel, nitinol, tantalum or allergy to contrast agents that cannot be pre-medicated 27. Severe dementia or lack of capacity due to conditions that result in either inability to provide informed consent for the trial/procedure, prevent independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up assessments 28. Emergency situations 29. Company employees or their immediate family members 30. Patient is under guardianship 31. Patient is participating in another clinical study for which follow-up is currently ongoing

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Transcatheter mitral valve repair (MRace Implant and Delivery System)
The MRace Implant is placed mitral valve posterior annulus using its delivery system via femoral vein access and a transeptal puncture Other Names: TMVr

Locations

Country Name City State
Brazil InCor - Instituto do Coração do Hospital das Clínicas da FMUSP São Paulo

Sponsors (2)

Lead Sponsor Collaborator
Polares Medical SA Polares Medical, Inc.

Country where clinical trial is conducted

Brazil, 

Outcome

Type Measure Description Time frame Safety issue
Primary Incidence of all-cause mortality following treatment with the MRace Implant and Delivery System Primary safety outcome 30-days follow-up
Primary Incidence of change from severe mitral regurgitation at baseline (Grade 3+ or more) to moderate or less mitral regurgitation (Grade 2+ or less) following treatment with the MRace Implant and Delivery System as evaluated by 2D TTE Primary performance endpoint 30-days follow-up
Secondary Rate of major safety events as defined by MVARC2 definitions Secondary safety endpoint Follow-up at 30 days, at 6 and 12 months, and at 2, 3, 4 and 5 years
Secondary Technical success rate per MVARC2 definitions All of the following must be present for technical success:
Absence of procedure mortality Successful access, delivery and retrieval of investigation delivery system Successful deployment and correct positioning of intended implant(s) Freedom from emergency surgery/re-intervention related to device or access procedure
Technical success is measured immediately following the procedure
Secondary Procedure success rate per MVARC2 definitions Both of the following must be present for procedure success:
Device success
Absence of major device or procedure-related serious adverse events as below:
Death Stroke Life-threatening bleed Major vascular complication Major cardiac structural complication Stage 2 or 3 AKI MI or coronary ischemia requiring PCI or CABG Shock, heart or respiratory failure requiring IV vasopressors, mechanical intervention or prolonged intubation Valve-related dysfunction, migration, thrombosis, or other complication requiring surgery or repeat intervention
Procedure success is measured at 30 days follow-up
Secondary Device success rate per MVARC 2 definitions All of the following must be present for device success:
Absence of procedure mortality or stroke Proper placement and positioning of device Freedom from unplanned re-intervention related to device or access procedure
Continued intended safety and performance of the device as below:
No evidence of structural or functional failure No device technical failure issues/complications MR reduction to moderate or less without stenosis
Device success is measured at 30 days, at 6 and 12 months, and at 2, 3, 4, and 5 years follow-up
Secondary Patient success rate per MVARC2 definitions All of the following must be present for patient success:
Device success Patient returned to pre-procedure setting No rehospitalization or reintervention for mitral regurgitation or heart failure • Functional improvement from baseline by one or more NYHA class 6MWT improvement from baseline by 50 metres or more
Patient success is measured at 12 months follow-up
See also
  Status Clinical Trial Phase
Completed NCT03283722 - PRESERVE-MITRAL Post-Market Registry
Not yet recruiting NCT06167213 - ALLIANCE Mitral: Safety and Effectiveness of SAPIEN X4 Transcatheter Heart Valve - Mitral N/A
Recruiting NCT06001489 - The Effects of 360-degree Virtual Reality on Pre-procedural Anxiety in Patients Awaiting Elective Cardiac Surgery Involving a Sternotomy N/A
Recruiting NCT06025149 - The Study on the Use of "UniLine" Bioprosthesis in the Treatment of Isolated Aortic and Mitral Valve Diseases
Completed NCT05193760 - Robustness Check of Placement and Measurement Algorithms for Blood Flow Measurement on Common Carotid Artery
Completed NCT05836558 - Are the Results of Minimally Invasive Mitral Valve Repair Still Satisfactory When Looked at Very Long-term?
Recruiting NCT05531253 - Respired Gases in Patients Post Cardiac Surgery
Completed NCT04045340 - Intraoperative Global Longitudinal Strain and Global Longitudinal Strain Rate as Predictors of Unfavorable Outcome in On-Pump Mitral Surgery
Active, not recruiting NCT04950192 - Philips Intracardiac Echocardiography (ICE) Clinical Registry
Recruiting NCT02925819 - Management and Clinical Outcomes of Patients With Severe Mitral Valve Disease Not Suitable for Surgery
Completed NCT03438825 - PRediction of Early PostoperAtive Right vEntricular Failure in Mitral Valve Replacement/Repair Patients
Completed NCT02000544 - Clinical Evaluation of a Modular Extracorporeal Circulation Circuit N/A
Recruiting NCT03574311 - Preoperative Intravenous Ferric Carboxymaltose and Placebo in the Treatment of Patients Undergoing Cardiac Surgery Phase 4
Recruiting NCT06153563 - Evaluation of the Elasticity of the Mitral Valve
Active, not recruiting NCT03539458 - Feasibility Study of the Tendyne Mitral Valve System in Mitral Annular Calcification N/A
Recruiting NCT05898230 - Retrospective Clinical Data Collection on Carbomedics OptiForm Mitral Heart Valve
Withdrawn NCT01849757 - Comparison of Priming Constituents in Patients Undergoing CPB Assisted Cardiac Surgery: HES 130/0.4 or Albumin 5% N/A
Active, not recruiting NCT04147884 - A Feasibility Study of the Millipede Transcatheter Annuloplasty Ring System in Patients With Functional Mitral Regurgitation N/A
Active, not recruiting NCT02097420 - HALO: A Single Arm Prospective Investigation of the SJM™ Masters HP™ 15mm Rotatable Mechanical Heart Valve N/A
Enrolling by invitation NCT04067635 - Primary Mitral Regurgitation Repair