Clinical Trials Logo

Clinical Trial Details — Status: Enrolling by invitation

Administrative data

NCT number NCT04528576
Other study ID # DragonFly-M-2020
Secondary ID
Status Enrolling by invitation
Phase N/A
First received
Last updated
Start date July 23, 2020
Est. completion date December 31, 2023

Study information

Verified date August 2021
Source Hangzhou Valgen Medtech Co., Ltd
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

To establish the safety and effectiveness of the DragonFly transcatheter mitral valve repair system in symptomatic patients with moderate to severe and severe mitral regurgitation who have been determined to be at an high risk of mortality with mitral valve surgery by the cardiac surgeon with concurrence by the local Heart Team


Description:

The subjects with moderate-to-severe (3+) and severe (4+) mitral valve regurgitation (MR) at high or prohibitive surgical risk will be evaluated by the study sites, and study eligibility confirmed by the echocardiographic core laboratory and eligibility committee. Those qualifying will then be treated with Dragonfly transcatheter mitral valve repair system after signing the informed consent. The follow-up will be conducted at discharge, 30 days, 6 months and 12 months after the operation. The primary endpoints are the incidence of major adverse events (MAE) at 30 days, and acute procedural success. Acute procedural success is defined as placement of one or more Dragonfly devices on the mitral valve with reduction of MR to 2+ or less. The secondary endpoints include all-cause mortality, cardiovascular mortality, incidence of serious adverse event, cardiovascular rehospitalization, NYHA functional class, mitral valve hemodynamics, acute technical success rate and device success rate at 6 months. Acute technical success is defined as no procedural mortality, successful in access, delivery, and retrieval of the device delivery system, and no emergency surgery or reintervention related to the device or access procedure in the catheterization laboratory. Device success is defined as no procedural mortality, proper delivery and deployment of the device, no unplanned surgical or interventional procedures related to the device, no specific device-related technical failure and or complications, function improvement of MR without significant stenosis (MR ≤ 2+) and without associated hemolysis or thrombogenesis.


Recruitment information / eligibility

Status Enrolling by invitation
Enrollment 20
Est. completion date December 31, 2023
Est. primary completion date December 31, 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. Age = 18 yrs 2. Moderate-to-severe (3+) or severe (4+) mitral valve regurgitation on transthoracic or transesophageal echocardiography, and confirmed by echocardiographic core laboratory 3. The patient is on optimal guideline directed medical therapy for heart failure and remains symptomatic. 4. High or prohibitive surgical risk as defined by either Society for Thoracic Surgery Risk Calculator score for valve replacement = 8 points; or STS score for valve repair = 6 points , prohibitive risk as determined by the clinical judgement of the site heart team, including a cardiac surgeon experienced in mitral valve surgery and a cardiologist experience in mitral valve disease, due to the presence of one or more documented surgical risk factors. 5. Anatomically suitable for mitral valve repair and can be treated by Dragonfly confirmed by both site investigators, echocardiographic core laboratory, and the eligibility committee. 6. Transseptal catheterization and femoral vein access is determined to be feasible 7. Life expectancy = 12 months 8. The subject or the subject's legal representative has been informed of the nature of the trial, willing to accept the experimental tests and follow-ups, and has provided written informed consent Exclusion Criteria: 1. History of heart transplantation, prior mitral valve replacement surgery. or transcatheter mitral valve procedure; 2. Leaflet anatomy which may preclude Dragonfly-MTM implantation and position, as judged by the site investigators and confirmed by the echocardiographic core laboratory and eligibility committee 3. Evidence of calcification or significant cleft in the grasping area 4. LVEF < 20% 5. LVESD= 60mm; 6. Mobile leaflet length<10mm 7. Mitral valve effective orifice area (EOA) < 3.5cm2 or in the opinion of site investigators and confirmed by the echocardiographic core laboratory and eligibility committee that mitral stenosis would result from implantation of the Dragonfly-MTM device. 8. Echocardiographic evidence of intracardiac mass, thrombus or vegetation; 9. Severe non-mitral valve disease requiring treatment . 10. Severe pulmonary artery hypertension (sPAP>70mmHg) 11. Severe right ventricular dysfunction; 12. Active endocarditis or previous mitral valve endocarditis; Active rheumatic heart disease or leaflets degenerated from rheumatic disease 13. Severe untreated coronary artery stenosis requiring revascularization; or with other cardiovascular disease requiring surgical treatment; 14. Extreme frailty 15. Hypertrophic cardiomyopathy, restrictive cardiomyopathy, constrictive pericarditis and any other structural heart disease causing heart failure other than dilated cardiomyopathy; 16. Renal failure requiring dialysis; 17. Blood cachexia including granulocytopenia (WBC < 3×109/L), acute anemia (HB < 90g/L), thrombocytopenia (PLT < 50×109/L), severe coagulopathy, and contradictions of anticoagulant and antiplatelet agents; 18. Evidence of an acute myocardial infarction in the prior 4 weeks; 19. Evidence of a shock in the prior 90 days; 20. Any percutaneous cardiac intervention or carotid surgery or any cardiac surgery within the 30 days prior to randomization; 21. Evidence of acute peptic ulcer upper or gastrointestinal hemorrhage in the prior 90 days; 22. Severe symptomatic carotid artery stenosis over 70% confirmed by echocardiography; 23. The subjects suffer from diseases which may lead difficulty in evaluating treatment (e.g., cancer, infection, severe metabolic disease, psychosis, etc.); or special cases that were evaluated by the heart team of local experimental center as not suitable for the surgical application of this clinical trial; 24. Life expectancy = 12 months; 25. Subject participating in an investigational drug or another device study within the past 1 month; 26. In the judgment of the investigator, subjects may not complete the trial according to poor compliance.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Dragonfly mitral valve repair system
With transesophageal echocardiographic guidance,implanting clip using Dragonfly mitral valve repair system

Locations

Country Name City State
China The Second Affiliated Hospital of Zhejiang University Hangzhou Zhejiang

Sponsors (1)

Lead Sponsor Collaborator
Hangzhou Valgen Medtech Co., Ltd

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Primary Incidence of acute procedural success The acute procedural success is defined as successful Dragonfly implantation, and residual MR of 2+ or less at discharge. An echocardiogram at 30 days can be accepted if the discharge image was not available or hard to interpret. A death before discharge or a re-operation of mitral valve prior to 30 days is defined as acute procedure failure 1 month
Primary Incidence of major adverse event (MAE) at 30 days Major adverse event is defined as one of the following components: death, myocardial infarction (MI), stroke, renal failure requiring dialysis, and cardiac surgery for Dragonfly device failure. 1 month
Secondary All-cause mortality Death from any cause 6 months
Secondary Cardiovascular mortality Death from cardiac causes 6 months
Secondary Incidence of serious adverse event (SAE) If the adverse event meets any of the criteria below, it is regarded as a serious adverse event (SAE): 1) results in death; 2) is life threatening, results in illness or injury; 3) requires inpatient hospitalization or prolongation of existing hospitalization; 4) results in a persistent or significant disability/incapacity; 5) results in a congenital anomaly/birth defect, fetal death, fetal distress; 6) results in medical or surgical intervention to prevent permanent impairment to body structure or a body function; 7) an important medical event that may not result in death, be life-threatening, or require hospitalization but may be considered serious when, based upon appropriate medical judgment, may jeopardize the patient or subject and/or may require intervention to prevent one of the outcomes listed in this definition. 6 months
Secondary NYHA NYHA functional class 6 months
Secondary Technical success must meet all of the following items: 1) no procedural mortality; and 2) successful in access, delivery, and retrieval of the device delivery system; and 3) no emergency surgery or reintervention related to the device or access procedure. Immediately after procedure
Secondary Device success must meet all of the following items:1) No procedural mortality; 2) Proper delivery and deployment of the device; 3) No unplanned surgical or interventional procedures related to the device; 4) No specific device-related technical failure or complication. 5) Improvement of MR without significant stenosis (MR = 2+) without associated hemolysis or thrombogenesis. 6 months
See also
  Status Clinical Trial Phase
Completed NCT03278574 - Flexible Band vs Rigid Ring for Degenerative Mitral Valve Disease N/A
Recruiting NCT04960280 - A Study to Evaluate a Computerized Stethoscope Called ©Voqx to Diagnose Heart Disease N/A
Recruiting NCT05021614 - Valveclip® Transcatheter Mitral Valve Repair Study N/A
Not yet recruiting NCT06167213 - ALLIANCE Mitral: Safety and Effectiveness of SAPIEN X4 Transcatheter Heart Valve - Mitral N/A
Withdrawn NCT05040451 - Carillon Mitral Contour System for Treatment of Exercise Induced Functional Mitral Regurgitation
Withdrawn NCT03714412 - Feasibility Study of Patients With Severe MR Treated With the Cardiovalve TMVR System N/A
Recruiting NCT02592889 - (MitraClip in Non-Responders to Cardiac Resynchronization Therapy) Phase 4
Completed NCT02355418 - The Role of Myocardial Fibrosis in Degenerative Mitral Regurgitation
Completed NCT01841554 - Cardioband With Transfemoral Delivery System N/A
Not yet recruiting NCT01431222 - Abrogation of Mitral Regurgitation Using the MitraClip System in High-Risk Patients Unsuitable for Surgery Phase 4
Not yet recruiting NCT03870516 - Left Chamber Function in Mitral Regurgitation and Predicting Outcome After Replacement and Targeting for Early Surgery N/A
Active, not recruiting NCT03230747 - SAPIEN M3 EFS: Early Feasibility Study of the Edwards SAPIEN M3 System for the Treatment of Mitral Regurgitation N/A
Enrolling by invitation NCT04031274 - Transcatheter Treatment for Combined Aortic and Mitral Valve Disease. The Aortic+Mitral TRAnsCatheter (AMTRAC) Valve Registry
Completed NCT05836532 - Long Term Results of Surgical and Percutaneous Double Orefices Mitral Repair in Patient With p2 Prolapse Causing Degenerative Mitral Regurgitation
Completed NCT05836480 - Immediate Suboptimal Result of Mitral Valve Repair: Late Implications in a Matched Cohort Study
Completed NCT05850026 - Mitral Regurgitation in Hypertrophic Obstructive Cardiomyopathy: Fix it in a Simple, Effective and Durable Way!
Recruiting NCT03975998 - Dutch-AMR: Early Mitral Valve Repair Versus Watchful Waiting in Asymptomatic Patients With Severe Mitral Regurgitation
Completed NCT01162083 - Identifying an Ideal Cardiopulmonary Exercise Test Parameter N/A
Suspended NCT00787293 - Study of Safety and Efficacy of the Percutaneous Reduction of Mitral Valve Regurgitation in Heart Failure Patients Phase 2
Recruiting NCT00745680 - Speckle Tracking Imaging and Realtime 3 Dimensional Echocardiograhy to Study LV Function and Remodeling After Acute Myocardial Infarction (AMI) N/A