The current standard of practice for the maintenance of epidural analgesia is through use of a continuous infusion pump. Enhanced technology now supports the use of programmed intermittent bolus (PIEB) administration. This novel drug delivery system provides small boluses of local anesthetic and opioid at programmed intervals. Several studies suggest that administration of PIEB allows a more extensive spread of local anesthetic in the epidural space and provides superior labour analgesia compared to traditional continuous epidural infusions. PIEB is associated with lower anesthetic consumption, a shorter second stage of labour and greater patient satisfaction. The authors are focusing on a PIEB setting known as the "Next Bolus". "Next Bolus" (NB) determines when the first PIEB bolus is given after the initiation of the epidural and starting the PIEB pump. Currently we set this to be 15-45 minutes. In an attempt to optimize resources, authors hope to determine the optimal NB interval that will provide adequate analgesia but limit overall drug consumption. An optimally timed next bolus should minimize drug costs and limit nurse and physician intervention by decreasing the need for manual boluses.Increased local anesthetic consumption can cause undesirable side effects such as itchiness, decreased blood pressure and motor blockade. By assigning patients to receive the NB at 15, 30 or 45 minutes the authors hope to find the interval that provides analgesia while minimizing side effects, improving patient safety. If the bolus is given too late then there may be increased pain, less patient satisfaction, and the need for more analgesia in the form of Patient Controlled Epidural Anesthesia or a manual bolus.The authors hope that determining the NB will result in an institutional change to improve patient outcomes and facilitate knowledge transfer. This information will be the first available research to help guide other obstetrical centres using PIEB technology in determining the optimal NB interval.


Clinical Trial Description

Background Enhanced epidural pump technology now supports the use of automated or programmed intermittent bolus (PIB) administration. Anesthesiologists can now program pumps to deliver small, regularly timed intermittent boluses for maintenance of labour analgesia and specify "lockout" intervals to ensure patient safety. Several studies suggest that administration of PIB may result in a more extensive spread of local anesthetic in the epidural space and provide superior labour analgesia compared to CEI. In a recently published systematic review by George et al. (1), PIB was associated with lower anesthetic consumption, a shorter second stage of labour and greater patient satisfaction compared to CEI (1). The optimal PIB volume and dosing interval for programmed intermittent bolus has not been determined. A small volume with a short bolus interval may be associated with similar drawbacks as continuous infusion, while a large volume bolus interval may be associated with increased breakthrough pain and reduced patient satisfaction. Wong et al. showed that extending the PIB interval from 15 min to 60 min with a larger PIB volume (10 mL vs. 2.5 mL) results in decreased anesthetic consumption without affecting patient satisfaction (3). Until recently, there was not a pump that could provide PIB along with PCEA. Smith Medical now produces the CADD pump with this feature. It ensures that that there are specific limits set to not allow "stacking" of boluses and potentially unsafe administration of local anesthetics. This pump now has more variables to program and determine the quality of labour analgesia. A variable that has not received any research attention is the "Next Bolus" (Figure 5). "Next Bolus" (NB) determines when the first PIB bolus is given after the initiation of the epidural and starting of the pump. Currently we set this to be 15-45 minutes depending on the clinician. Determining the optimal timing of the NB is important because if the bolus is given too late there may be increased pain and less patient satisfaction. This could lead to earlier initiation of PCEA, more frequent PCEA attempts and possibly the need for physician intervention for a manual bolus. As more local anesthetic is delivered, the patient may have a decrease in blood pressure or greater motor blockade (i.e. leg weakness) than desired. Design & Procedure Potential participants will be identified by research personnel by communicating with the attending anesthesiologist on the Birth Unit and the Clinical Leader of Operations for the Birth Unit at the IWK Health Centre. Birth Unit nurses will receive an educational session and training provided by the research coordinator prior to study commencement. Birth unit nurses will be notified by the Clinical Leader of Operations if their patient meets study inclusion criteria. The patient's nurse will review options for labour pain relief with the patient. These options include non-pharmacological measures (baths, massage, hypnosis etc.), inhaled nitrous oxide, opioid injections, or an epidural. When labour pain management options are introduced, the nurse will provide the patient with a brochure that includes basic study information. If an epidural is requested for labour analgesia, nurses who have received education regarding the study, will ask the patient if they would be willing to speak with research staff. With their consent, participants will be approached by study personnel and informed, written consent will be obtained. As standard care in the birth unit, upon request of labour analgesia, the cervix will be measured and a baseline pain score and blood pressure will be determined. A staff anesthesiologist will use a combined spinal-epidural (CSE) technique to initiate labour analgesia. As per standard practice at the IWK, an IV catheter will be in place before initiation of the technique. With the patient in the sitting position, the epidural space will be identified at the L3-4 or L2-3 interspace with a 17G, 9 cm Tuohy epidural needle using a loss of resistance to air or saline (< 1 mL) technique. A 27G, 12 cm Whitacre spinal needle will be placed into the shaft of the epidural needle and the presence of cerebrospinal fluid in the hub of the spinal needle will confirm dural puncture. Bupivicaine 0.25% 0.8 mL (2 mg) + Fentanyl 10 mcg (total 1 mL) will be injected into the intrathecal space. Each participant will be randomly allocated (using a computer generated randomization table) to one of three groups. Group assignments will be sealed in sequentially numbered envelopes that will be opened by study personnel following the consent process. The pump will be programmed by an unblinded member of the anesthesia team (anesthesiologist or anaesthesia assistant) and maintenance epidural analgesia will be initiated in accordance with IWK policies when the epidural procedure is complete. The individual programming the pump will not be collecting data. The start time of the pump will be recorded on the envelope and the sealed envelope will be given to the study personnel. The pump will be connected and initiated once the epidural procedure is complete and will start the infusion exactly 5 minutes after the intrathecal injection. Each participant will have the same PIB settings (PIB bolus 8 mL, PIB interval 45 minutes). Group A will be assigned a NB of 15 minutes, group B 30 minutes and group C 45 minutes. The data collection will take place in the patient's assigned labour room in the IWK Birth Unit. The CADD Solis Ambulatory Infusion System (Smiths Medical ASD, Inc., St Paul MN) will be used to administer the programmed intermittent epidural bolus doses and patient-controlled epidural analgesia (PCEA). The current IWK labour analgesia standard ensures each labour room is equipped with a Smith Medical CADD pump, epidural infusion tubing and an epidural procedure tray. No new or additional supplies or personnel will be required for the study. Prior to study commencement, the research assistant will be trained by one of the investigators (anesthesiologist) on how to complete a dermatome sensory evaluation and Bromage score. In addition, the research assistant will receive training from the anesthesiologist regarding how to instruct patients to use the PCEA device. For all groups the PCEA will remain standardized. If after two confirmed PCEA doses that participant's pain is not suitably controlled the anesthesiologist will be consulted to provide a manual bolus (0.1% ropivacaine 10 mL). The patient and research personnel recording data will be blinded to the group assignment. Data to be collected Demographic data and health history Medical record number, maternal age, height, weight, BMI. Labour Information Gestational age, cervical dilation at initiation of CSE analgesia, duration of labour (initiation of analgesia to delivery), maximum oxytocin infusion rate during labour, mode of delivery, time from initiation of analgesia to delivery. Analgesia Data Maintenance epidural solution volume administered from programmed intermittent bolus pump, time of first administered PCEA bolus request, number of PCEA bolus requests and delivered doses, PCEA ropivacaine dose, time to first request for manual bolus, number of manual bolus doses, manual bolus ropivacaine dose, total ropivacaine dose, highest thoracic dermatome sensory level to pin prick at 0, 15, 30, 45, 60, 120, 180, 240, 300, and 360 minutes, along with a modified Bromage score, hypotension, need for vasopressors. Satisfaction Scores Overall maternal satisfaction scores (NRS) will be sought within one day of delivery. Patients will be asked "On a scale from 0 to 100, how satisfied were you with the pain control provided by the epidural during your labour?" Data Collection In keeping with CONSORT guidelines all participants enrolled will be included in an intention to treat analysis. Descriptive statistics will be expressed as mean +/- standard deviation. The Student's t-test will be used for comparison of the means of continuous, normally distributed data. Two-way ANOVA or Friedman test will be used for variable differences in groups, and Bonferroni or Tukey HSD test will be used for multiple comparisons. Categorical data are to be analyzed using χ2 test or Fisher's exact test, as appropriate. The investigators will perform the statistical analysis, with the assistance of collaborating statistician. An interim analysis will not be conducted and α set at 0.05 for significance. A sample size of 26 per group will have an 80 % power to detect a reduction in the time to first administered PCEA request by 20 minutes at alpha=0.05. To account for any dropouts, we will aim to recruit 35 patients per group. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03044392
Study type Interventional
Source IWK Health Centre
Contact
Status Active, not recruiting
Phase N/A
Start date June 5, 2017
Completion date July 1, 2024

See also
  Status Clinical Trial Phase
Completed NCT03539562 - Therapeutic Rest to Delay Admission in Early Labor: A Prospective Study on Morphine Sleep
Not yet recruiting NCT04662450 - Evaluation and Management of Parturients' Pain Intensity N/A
Completed NCT02885350 - Spinal or Epidural Fentanyl or Sufentanil for Labour Pain in Early Phase of the Labour Phase 4
Completed NCT02550262 - Programmed Intermittent Epidural Bolus for Labor Analgesia During First Stage of Labor N/A
Completed NCT01598506 - Intrathecal Hydromorphone for Labor Analgesia Phase 2
Withdrawn NCT01636999 - Comparing Sedara to Butorphanol in Early Labor N/A
Completed NCT00987441 - Epidural Labor Analgesia and Infant Neurobehavior N/A
Completed NCT00755092 - Effect of Doula in Nulliparas and Multiparas N/A
Terminated NCT00787176 - The Association Between Fluid Administration, Oxytocin Administration, and Fetal Heart Rate Changes N/A
Recruiting NCT06036797 - Efficacy and Safety of Hydromorphone-ropivacaine Versus Sufentanil-ropivacaine for Epidural Labor Analgesia Phase 2
Completed NCT05512065 - Changes in Velocimetric Indices of Uterine and Umbilical Arteries Before and After Combined Spinal-epidural Analgesia in Laboring Women N/A
Completed NCT05327088 - Epidural Dexmedetomidine vs Nalbuphine for Labor Analgesia Phase 2
Completed NCT03103100 - Comparing Bupivacaine, Lidocaine, and a Combination of Bupivacaine and Lidocaine for Labor Epidural Activation Phase 3
Recruiting NCT03623256 - Comparison of Intrathecal Versus Epidural Fentanyl on Fetal Bradycardia in Labor Combined Spinal Epidural Analgesia Phase 4
Active, not recruiting NCT02271100 - Assessment of the Use of Ultrasound for Epidural Catheter Placement and Comparison With Palpation Technique N/A
Completed NCT02926469 - Virtual Reality Analgesia in Labor: The VRAIL Pilot Study N/A
Completed NCT03712735 - Programmed Intermittent Epidural Bolus For Laboring Obstetrical Women Phase 4
Not yet recruiting NCT05565274 - Outcome of Combined Tramadol and Paracetamol Versus Pentazocine as Labour Analgesia Among Parturients N/A
Recruiting NCT02575677 - Oxycodone in Treatment of Early Labour Pain Efficacy and Safety
Recruiting NCT01708668 - The Effects of Intermittent Epidural Bolus on Fever During Labor Analgesia N/A