Clinical Trials Logo

Clinical Trial Summary

This is a randomized control study where adult patients had been divided randomly into two equal groups using video laryngoscope in group (V) and flexible intubating laryngoscope in group (F)


Clinical Trial Description

Routine pre-operative assessment including history taking, clinical examination, and laboratory tests. Patients were admitted to the operating room with a small 20G IV cannula after applying inclusion & exclusion criteria and airway assessment by applying El Ganzuri multivariate risk index for difficult intubation which include assessment of the following : inter-incisor gap, Mallampati classification, head &neck movement, buck teeth prognathism, thyromental distance, body weight and history of difficult intubation. Operating room was prepared using : Difficult airway cart that includes different size oral airways, endotracheal tubes, different sizes face masks & laryngeal airway masks Suction apparatus to be ready for use Video laryngoscopy The flexible intubating laryngoscopy with the tube mounted over the fiberscope before the procedure. Standard monitoring devices were applied including ECG, non invasive blood pressure. pulse oximetry and capnography after intubation Patients were then pre-oxygenated via face mask for three minutes and using 0.01 mic/kg atropine then general anesthesia is induced using fentanyl 1-2 mic/kg followed by propofol 2 mg/kg and esmeron 0.5 mg/kg. The patient is mechanically ventilated using face mask until full relaxation is established after 3-5 minutes. The intubation is done using video laryngoscope in group (v) or using flexible intubating laryngoscopy in group (f) In the first group (v) The video laryngoscope was introduced with the patient appropriately positioned, the operator used the left hand to introduce the video laryngoscope into the midline of the Oropharynx and gently advances until the blade tip pass the posterior portion of the tongue. Using video visualization, the ETT was then advanced on a smooth curve through the glottis and intubation proceeds. Viewing the entire insertion step on the video screen allows the operator to quickly become facile with the motion of gently rotating or angling the tube using the right hand to redirect as necessary. In the second group(f) patients positioned supine with the operator standing at the head of the bed. Simple chin lift and jaw thrust may improve the view through the flexible laryngoscopy and also help to prevent airway obstruction. The endotracheal tube should be lubricant to facilitate its subsequent advancement into the trachea. Once the endotracheal tube is in place, the scope is removed, and the patient is ventilated. Flexible intubating laryngoscopy is often performed with the operator looking through the eyepiece. However, connecting the flexible laryngoscopy to a monitor is often advantageous. After collecting demographic data of the patient (age, sex, body mass index & ASA) The following parameters will be measured : Intubation time, Hemodynamic parameters, success rate and number of attempts & incidence of complications. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04628611
Study type Interventional
Source National Cancer Institute, Egypt
Contact
Status Completed
Phase N/A
Start date March 1, 2016
Completion date February 1, 2020

See also
  Status Clinical Trial Phase
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Suspended NCT04253795 - Nonintubated Versus Intubated Anesthesia in Video-assisted Thoracic Surgery N/A
Completed NCT02864017 - Immuno Nutrition by L-citrulline for Critically Ill Patients N/A
Completed NCT02900807 - CT-scan Airways Mensuration - Correlation to External Measurements
Completed NCT01823328 - Ketamine Versus Etomidate for Rapid Sequence Intubation Phase 4
Completed NCT02350933 - Endoscopic Evaluation of the Paediatric Airway After Prior Prolonged (>24 h) Tracheal Intubation N/A
Completed NCT01170455 - Nasal Intubation Using the Blind Intubation Device N/A
Completed NCT00980590 - Airway Scope and Macintosh Laryngoscope for Tracheal Intubation in Patients Lying on the Ground N/A
Completed NCT05515107 - The Laryngoscopic View With C-MAC Videolaryngoscope Miller Blade Lifting the Epiglottis or the Vallecula in Children N/A
Completed NCT06249659 - Impact of Extubation Location After Surgery on Perioperative Times
Completed NCT03677505 - KoMAC Videolaryngoscope for Double-lumen Intubation N/A
Completed NCT03328182 - Assessment of an Oral Endotracheal Subglottic Tube Holder N/A
Recruiting NCT02277652 - Endotracheal Intubation Devices N/A
Recruiting NCT02073786 - Rigid Video Stylet Vs Conventional Lightwand Intubation N/A
Recruiting NCT02277405 - Pediatric Intubation During Resuscitation N/A
Completed NCT02277418 - Venner a.p. Advance Video Laryngoscope N/A
Completed NCT00956592 - Clinical Evaluation of the Storz CMAC Laryngoscope N/A
Completed NCT01003327 - Comparison of the I-gel Laryngeal Mask and the Classic Laryngeal Mask in Patients With a BMI>25 Phase 4
Completed NCT00783731 - Low Dose of Midazolam is Superior to Conventional Dose for Rapid Sequence Intubation in Emergency Department (ED) N/A
Recruiting NCT03887897 - First Attempt Intubation Rate With Airtraq vs Macintosh Direct Laryngoscope N/A