Intraocular Pressure Clinical Trial
Official title:
The Effect of Labor on Intraocular Pressure Fluctuation in Healthy Eyes
Glaucoma is a multifactorial disease, an important risk factor of which is increased intraocular pressure. Fluctuations in intraocular pressure are often associated with vaginal birth, although intraocular pressure during active pushing during stage II has never been measured.. The study will be conducted on a group of patients with healthy eyes on patients who have completely fine vision or have a small refractive error and are accustomed to wearing contact lenses. The measurement of intraocular pressure itself will be carried out using SENSIMED Triggerfish contact lenses, which measure pressure every 5 minutes for 30s. This period roughly corresponds to the duration of 1-2 contractions. Inclusion in the study will be offered to patients in the 35th to 37th week of pregnancy. Prior to measurement patients will be sent to an eye clinic for a detailed examination of both eyes, which includes measuring intraocular pressure. Subsequently, pregnancy checks will take place according to the standard scheme and in the standard scope. At the onset of uterine contractions, an ophthalmologic consultant will be called, which will measure intraocular pressure between contractions using the Tonopen device and put on SENSIMED Trigerfish contact lenses in combination with a local anesthetic. The patient will have these lenses until the end of the third stage of labor, i.e. 2 hours after the birth, when the lenses are removed. In the second stage of labor, continuous monitoring by a cardiotocograph will take place. Subsequently, the obtained data from the cardiotocograph and contact lenses will be evaluated and compared by a team of ophthalmologists and gynecologists, where the investigators will be able to assess the individual fluctuations in intraocular pressure depending on the individual contractions. The aim of the study is to demonstrate or disprove the risks to the glaucoma patient due to increased intraocular pressure during active pushing in combination with uterine contraction.
Glaucoma is a multifactorial disease, an important risk factor of which is increased intraocular pressure. Fluctuations in intraocular pressure are often associated with vaginal birth, although intraocular pressure during active pushing during stage II has never been measured. The study will be conducted on a group of patients with healthy eyes on patients who have completely fine vision or have a small refractive error and are accustomed to wearing contact lenses. The measurement of intraocular pressure itself will be carried out using SENSIMED Triggerfish contact lenses, which measure pressure every 5 minutes for 30s. This period roughly corresponds to the duration of 1-2 contractions. Inclusion in the study will be offered to patients in the 35th to 37th week of pregnancy.Prior to measurement patients will be sent to an eye clinic for a detailed examination of both eyes, which includes measuring intraocular pressure. Subsequently, pregnancy checks will take place according to the standard scheme and in the standard scope. At the onset of uterine contractions, an ophthalmologic consultant will be called, which will measure intraocular pressure between contractions using the Tonopen device and put on SENSIMED Trigerfish contact lenses in combination with a local anesthetic. The patient will have these lenses until the end of the third stage of labor, i.e. 2 hours after the birth, when the lenses are removed. In the second stage of labor, continuous monitoring by a cardiotocograph will take place. Subsequently, the obtained data from the cardiotocograph and contact lenses will be evaluated and compared by a team of ophthalmologists and gynecologists, where the investigators will be able to assess the individual fluctuations in intraocular pressure depending on the individual contractions. The aim of the study is to demonstrate or disprove the risks to the glaucoma patient due to increased intraocular pressure during active pushing in combination with uterine contraction. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT03016234 -
IOP Changes With Different Anesthetic Agents During Laparoscopic Colorectal Surgery
|
N/A | |
Completed |
NCT04863209 -
Effect of Osteopathic Techiniques on Intraocular Pressure
|
N/A | |
Completed |
NCT02646033 -
Quantitative Rise in Intraocular Pressure in Steep Trendelenburg Position
|
||
Completed |
NCT03139708 -
The Effect of Brimonidine on Intraocular Pressure When Dilating Routine Patients
|
Phase 1 | |
Recruiting |
NCT02697825 -
Intraocular Pressure Versus Optic Nerve Sheath Diameter
|
N/A | |
Completed |
NCT02985567 -
An Observational Study of the Use of Chloral Hydrate for Ophthalmic Procedures in Children
|
N/A | |
Withdrawn |
NCT00837226 -
Effects of Weight Loss From Bariatric Surgery on Intraocular Pressure (IOP)
|
N/A | |
Completed |
NCT02136589 -
Effect of NSAID on Travoprost-induced Conjunctival Hyperemia and IOP Reduction in Normal Eyes
|
Phase 4 | |
Completed |
NCT03123614 -
Loteprednol vs. Prednisolone and Fluorometholone
|
Phase 4 | |
Completed |
NCT05763056 -
Effects of Intubation on Intra-ocular Pressure and Optic Nerve Sheath Diameter
|
N/A | |
Completed |
NCT03359200 -
Analysis of the Microbiota in Goldmann Applanation Tonometers at a Reference Service in Goiânia
|
N/A | |
Withdrawn |
NCT02558309 -
Optic Nerve Head Quantification While Reducing Elevated Intracranial Pressure
|
N/A | |
Completed |
NCT02816905 -
Ocular-hypertensive Response to Topical Steroids in Children After Bilateral Strabismus Surgery
|
Phase 4 | |
Completed |
NCT01786954 -
iCare vs Tonopen vs Goldmann Applanation Post-vitrectomy Surgery
|
N/A | |
Completed |
NCT00552019 -
Intraocular Pressure (IOP) Assessed by Dynamic Contour Tonometer (DCT) and Goldman Applanation Tonometry (GAT)
|
N/A | |
Completed |
NCT00428740 -
Long-Term IOP Fluctuation and VF Progression After Triple Procedure
|
N/A | |
Completed |
NCT04360369 -
Comparison of Intraocular Pressure Measurements Between Reichert Tono-Vera Tonometer and Goldmann Tonometry
|
N/A | |
Completed |
NCT04521140 -
Assessing eFficacy and Safety of DEXTENZA 0.4 mg inseRt, Following Corneal Transplant Surgery
|
Phase 4 | |
Completed |
NCT05167773 -
Clinical Study of the Topcon Tonometer TRK-3
|