Clinical Trial Summary

Adequate perfusion is necessary for maintaining tissue function. This applies also for the eye, in which ocular perfusion pressure (OPP) is generally estimated as the difference between mean arterial pressure (MAP) and intraocular pressure (IOP). In the latter formula, IOP substitutes for central retinal venous pressure (CRVP), which is assumed to be slightly higher than IOP to allow blood flow to exit the eye. It has, however, been found that in some patients CRVP is elevated and significantly higher than IOP, which would lead to a decrease in OPP which is not taken in account with the proposed formula. Therefore, techniques for measurement of CRVP are warranted. Recently, a new, method for measurement of this parameter without corneal contact has been introduced. Briefly, with this method, IOP is elevated until the vein collapses, which then equals CRVP. In the present study this technique will be applied in 12 healthy subjects to validate whether the values that are preset by the device correlate to measurements obtained with standard Goldmann applanation tonometry. For this purpose, IOP will be experimentally increased in steps of approximately 5mmHg until it reaches 40mmHg as measured by applanation tonometry. After a resting period of 30 minutes, IOP will be again increased stepwise to 40 mmHg while retinal vessel diameters will be monitored using dynamic vessel analyzer. During this session CRVP will be measured. After another resting period of 30 minutes IOP will be stepwise increased a third time and after each step OCT, OCT-A and OCT EDI will be performed.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT04044274
Study type Interventional
Source Medical University of Vienna
Contact
Status Completed
Phase N/A
Start date July 24, 2019
Completion date February 2, 2021

See also
  Status Clinical Trial Phase
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT03016234 - IOP Changes With Different Anesthetic Agents During Laparoscopic Colorectal Surgery N/A
Completed NCT04863209 - Effect of Osteopathic Techiniques on Intraocular Pressure N/A
Completed NCT02646033 - Quantitative Rise in Intraocular Pressure in Steep Trendelenburg Position
Completed NCT03139708 - The Effect of Brimonidine on Intraocular Pressure When Dilating Routine Patients Phase 1
Recruiting NCT02697825 - Intraocular Pressure Versus Optic Nerve Sheath Diameter N/A
Completed NCT02985567 - An Observational Study of the Use of Chloral Hydrate for Ophthalmic Procedures in Children N/A
Withdrawn NCT00837226 - Effects of Weight Loss From Bariatric Surgery on Intraocular Pressure (IOP) N/A
Completed NCT02136589 - Effect of NSAID on Travoprost-induced Conjunctival Hyperemia and IOP Reduction in Normal Eyes Phase 4
Completed NCT03123614 - Loteprednol vs. Prednisolone and Fluorometholone Phase 4
Completed NCT05763056 - Effects of Intubation on Intra-ocular Pressure and Optic Nerve Sheath Diameter N/A
Completed NCT03359200 - Analysis of the Microbiota in Goldmann Applanation Tonometers at a Reference Service in Goiânia N/A
Withdrawn NCT02558309 - Optic Nerve Head Quantification While Reducing Elevated Intracranial Pressure N/A
Completed NCT02816905 - Ocular-hypertensive Response to Topical Steroids in Children After Bilateral Strabismus Surgery Phase 4
Completed NCT01786954 - iCare vs Tonopen vs Goldmann Applanation Post-vitrectomy Surgery N/A
Completed NCT00552019 - Intraocular Pressure (IOP) Assessed by Dynamic Contour Tonometer (DCT) and Goldman Applanation Tonometry (GAT) N/A
Completed NCT00428740 - Long-Term IOP Fluctuation and VF Progression After Triple Procedure N/A
Completed NCT04360369 - Comparison of Intraocular Pressure Measurements Between Reichert Tono-Vera Tonometer and Goldmann Tonometry N/A
Completed NCT04521140 - Assessing eFficacy and Safety of DEXTENZA 0.4 mg inseRt, Following Corneal Transplant Surgery Phase 4
Completed NCT05167773 - Clinical Study of the Topcon Tonometer TRK-3