Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to determine whether this new intramedullary fixation is effective in the treatment of intertrochanteric fracture.


Clinical Trial Description

With the progress of aging society, elderly patients with intertrochanteric fractures were occurred more and more. The best recommend treatment is surgical treatment of intramedullary fixation. However, existing methods of intramedullary fixation could not be restored the integrated interior support, and it will occur early hip varus. Meanwhile, the varus deformity will no longer develop if the two ends contact with wach other. This new intramedullary fixation device can overcome the existing shortage of intramedullary fixation devices and supporting the inside of the problem. It can prompting the fracture site to obtain a stronger initial stability, improve fracture healing rate, reduce the incidence of varus and allow patients with early weight-bearing walking. This new type of intramedullary fixation of intertrochanteric fractures of devices, including a proximal femoral anatomy and adapt to proximal femoral nail, proximal femoral nail through the femoral head and distal femur compression screw locking screw, its main features are: 1. The proximal femoral nail was made from titanium, its proximal part is narrow inside and wide outside structure. It looks like a trapezoidal in cross-section. This device was matched with the anatomy of proximal femur and its mechanical reliability. 2. The tip of compression screw was designed thread. It can come through the intramedullary nail, produce slide and sustained pressure. 3. The femoral support screw was made in cylindrical, had a blunt rounded tip. The tip of the femoral support screw was tabling with the groove of compression screw. This design can support interior mechanical stability. At the same time, the support screw from the femoral head and neck compression screw can slide fine-tuning, so it has a direct offset against varus and femoral neck rotating shift to prevent secondary loss of fracture reduction. The screw in the femoral head also can prevent cutting occurs. 4. This device can be used in minimally invasive approach of percutaneous and implanted in body. Reduce reduction time, fracture interference and help the natural healing of fractures. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01437176
Study type Interventional
Source Chinese PLA General Hospital
Contact Tang Peifu, Dr.
Phone 861099638101
Email pftang301@126.com
Status Recruiting
Phase N/A
Start date September 2011
Completion date August 2024

See also
  Status Clinical Trial Phase
Recruiting NCT01797237 - Outcome Comparison Between PFNA and InterTAN Phase 4
Active, not recruiting NCT02627040 - Intertrochanteric Femoral Fracture Fixation Trial N/A
Completed NCT00555945 - Re-Evaluation of GAmma3 Intramedullary Nails in Hip Fracture (REGAIN) N/A
Completed NCT02512094 - Validity and Reliability of Thai Version of Barthel Index for Hip Fracture Patients N/A
Completed NCT03000972 - PFN-A Augmentation for Intertrochanteric Femoral Fractures N/A
Completed NCT01380444 - Intramedullary Nail Versus Sliding Hip Screw Inter-Trochanteric Evaluation N/A