Inguinal Hernia Clinical Trial
Official title:
Needlescopic Inversion and Snaring for Inguinal Hernia in Girls Using 1.6-mm Instruments
Two Millimetres needlescopic instruments induce minimal damage to the abdominal wall and have excellent cosmetic results. However, these instruments are fragile and expensive with short weak jaws. The aim of this study is to present a novel needlescopic approach using 1.6-mm Suture Grasper Device [SGD], modified polypectomy snare and a home-made Snare (HMS) for the treatment of congenital inguinal hernias [CIH] in girls. Over a period of one year from March 2018 to March 2019 a prospective study was conducted in three tertiary centres on 53 girls presented with CIH. Preoperative inguinoscrotal U/S was done for all patients to confirm the diagnosis and to measure the diameter of internal inguinal ring [IIR]. All patients were repaired using needlescopic inversion and snaring of the hernia sac using 2-SGDs and a snare. Follow up period ranged from 12 to 24 (Median 16.5) months. Fifty-three girls with 74 hernias were included in this study. Their mean age was 37.8 months. Internal inguinal ring diameter (IIR) ranged between 8-15 mm with a mean of 11.8±2.8mm. Mean operative time was 15.5 minutes in bilateral and 11.4 minutes in unilateral cases. Mean operative time for inversion, snaring, and sac extraction was 4.2±1.3 minutes. All cases were completed successfully without conversion and without complications. Follow up period ranged from 12 to 24 (Median 16.5) months with non-visible scar and no recurrence among the studied patients. Needlescopic inversion and snaring of inguinal hernia using 1.6mm instruments is a safe, rapid and feasible method for CIH repair in girls with invisible scar and no short-term recurrence.
Operative details: Patient lies in supine position at upper part of OR table towards right edge. Operating table is tilted to opposite side of hernia with 30-degree Trendelenburg position. Operator stands on patient's right side during either uni-or bi-lateral hernia. Camera man stands at table head and monitor facing patient's feet. Vertical trans umbilical 5-mm incision [Point A] was made and 5-mm trocar passed under vision using open technique. Pneumoperitoneum is then established with CO2 flow of 1.5-2.5 L/min keeping intraabdominal pressure between 8-12 mmHg according to patients' age and weight. Early in our experience, a two-mm incision is done at a point located midway between umbilicus and symphysis pubis [point B] for 2-mm port passed under direct vision and a tiny 11-blade scalpel puncture was done at the corresponding Mac-Burney's [Point C] for SGD. Abdomen was then explored to confirm the diagnosis and detect contralateral or other hernias if present. One SGD was introduced through point B (SGD-B) and another one through point C (SGD-C). Both SGDs were used to invert the hernia sac by gradual sustained alternating traction on the round ligament. Each SGD hands to the other one till complete inversion occurs, this is known by the hernial sac hanging from internal ring without retracting-back inside the inguinal canal. Occasionally, investigators had to fix the sac to the anterior abdominal wall by a suture [Prolne 2/0 on a half circle 20-mm needle] placed percutaneously lateral to the corresponding Mac-Berney's point to prevent its retraction. Then, the MPS was introduced via the trocar at point B and opened inside the abdomen and SGD-C passed inside the loop of MPS and re-catches the hernial sac, which is then twisted around its neck several times. MPS was closed tightly at the proper neck and coagulation diathermy current is applied to it leading to separation of the hernia sac. Detached sac (grasped by SGD-C) was then pushed antegradely out through the umbilical port. In some cases, the Fallopian's tube was closely related to the round ligament and investigators had to divide the round ligament with the long microdiathermy needle introduced directly via point B before hernia sac snaring to avoid its injury during the application of MPS. Deflation of the abdomen is done, and umbilical fascial incision is closed using 2/0 or 3/0 Polygalctin suture and umbilical skin layers were closed using 4/0 Polygalctin suture. Later in the study, we were able to innovate a HMS by using the guide wire of central venous catheter looped through VAC and connected to a regular diathermy probe and investigators modified our technique. An11-blade scalpel puncture is done at point-B through which VAC is introduced directly instead of 2-mm trocar. This VAC is used for the insertion of HMS and SGD-B. Then, complete inversion of the sac was done using 2 SGDs as previously described. Followed by introduction of HMS through #14-G VAC at point-B and the procedure completed as before. Postoperative Management: Patients received antibiotics and analgesics according to hospital protocols. Oral fluids started 2 hours post operatively and diet was advanced gradually as tolerated. Patients were discharged the same post-operative day. Follow up period ranged from 12 to 24 (Median 16.5) months. with for recurrence and cosmetic results. Discussion: In the last 2 decades, pediatric inguinal hernia repair witnessed a huge evolution with laparoscopic approaches attracting more and more pediatric surgeons and laparoscopic hernia repair became well-established and popular technique with comparable recurrence rates and operative time. Moreover, laparoscopy allows diagnosis of contralateral and other coexisting hernia with a chance for simultaneous repair. Early in the laparoscopic era, its drawbacks were long learning curve, need for smaller instruments for younger kids, higher recurrence rates, and to somewhat smaller but visible scars compared to conventional open hernia repair. With time, regular use of laparoscopy, fine instruments, introduction of newer concepts and techniques for tailoring which laparoscopic technique fits for each patient the results came to be similar or even better than that of conventional repair. Laparoscopy for female inguinal hernia repair was first introduced in 1997 by El Gohary. He described hernial sac inversion and ligation in girls using 5-mm instruments and endo loop with excellent results. During the evolution of laparoscopic repair of hernia, results improved very much by cautery of the IIR enhancing peritoneal fibrosis hence reducing recurrence rates compared to simple peritoneal closure. Snaring is routinely used for colonic polypectomy with excision of polyps at its proper neck using coagulation current without colonic wall perforation. In this study it is proposed that inversion and snaring of the hernia sac results in a herniotomy with narrow raw area at its neck of the hernia sac combining the benefits of both peritoneal disconnection and thermal injury to prevent recurrence. Recently there is a report of early results of inversion, and snaring of hernial sac using 3-mm instruments and commercial polypectomy snare in girls with encouraging results and no recurrence. On application of monopolar diathermy current to the snare itself, the hernial sac will shrink with almost closure of internal ring. No recurrence was reported with no perioperative complications except for lymphocele developed at the level of labium major 2 weeks postoperatively that completely resolved after 6 months. Commercially available polypectomy snare length is 230-cm which imposed discomfort and difficulty using it for hernial sac snaring. So, investigators opted to shorten it from 230-cm to 50 cm to facilitate its usage. The biomedical engineering department was contacted and succeeded to shorten it to the required length. In this study, in the first 2 months investigator used this modified snare successfully but it is still not fully satisfied as it adds extra cost [needs 2-mm trocar for insertion], needs technical assistance for shortening and re-sterilization. Investigator came into another innovation by developing a home-made snare (HMS) made of central venous catheter guide wire looped through VAC and connected to a regular diathermy probe. Each wire can be cut to make 2-3 snares. It is shorter, easy to use, cheaper and avoided the use of expensive trocar 2-mm. This HMS was then applied for all upcoming cases after that. It is well known that, one of the most annoying factors lead to delayed acceptance of laparoscopic repair for CIH among pediatric surgeons is visible scars even though they are smaller compared to the hidden skin crease scar of the open repair which ultimately resulted in development of needlescopic repair. Chock et al. reported that despite good cosmetic results, 2-mm instruments are expensive, delicate, flexible, and with short and weak jaws limiting their use on a wide scale. Others reported that needlescopic instruments can be used only by expert surgeons as it can be bended easily and its small jaws limit the power of grasping the tissue with unsuitability for ideal retraction and tissue handling. In contrary, SGD used for port closure is only 1.6 mm in diameter with adequate length, strong shaft, ergonomic handle, cheap, wide jaw and offers a very good tissue grip. According to the results of this study, needlescopic inversion, snaring and complete excision of the hernia is a progress of minilaparoscopic surgery where two MSDs [1.6-mm diameter] were used instead of 2-3-mm instruments for the treatment of CIH in girls. It avoids the disadvantages of 2-mm instruments. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03023462 -
Efficacy of an Anterior Quadratus Lumborum Block vs. a TAP-block for Inguinal Hernia Repair
|
N/A | |
Completed |
NCT04272320 -
The Efficacy of Transversalis Fascia Plane Block in Pediatric Inguinal Hernia Repair
|
N/A | |
Recruiting |
NCT03904888 -
Conventional Versus Robot Assisted Laparoscopic Inguinal Hernia Repair
|
N/A | |
Recruiting |
NCT03856710 -
Self Fixating Versus Stapled Mesh for Laparoscopic Inguinal Hernia Repair
|
N/A | |
Completed |
NCT02240550 -
A Comparative Clinical Study to Evaluate the Effectiveness of ProFlor vs. Lichtenstein for Inguinal Hernia Repair
|
N/A | |
Completed |
NCT01679353 -
Comparison of Analgesic Effect of Magnesium Added to Ropivacaine and Ropivacaine Alone in Caudal Analgesia on Postoperative Pain Control in Pediatric Patients Undergoing Inguinal Hernia Repair
|
N/A | |
Completed |
NCT01943760 -
Tamadol Wound Infiltration in Children Under Inguinal Hernioplasty
|
Phase 4 | |
Recruiting |
NCT01450345 -
Efficacy of Pre-operative Oral Pregabalin in Ambulatory Inguinal Hernia Repair for Post Operative Pain
|
Phase 3 | |
Active, not recruiting |
NCT00968773 -
Rebound Hernia Repair Device Mesh Trial
|
Phase 4 | |
Completed |
NCT01000116 -
Fibrin Glue Versus Tacked Fixation in Groin Hernia Repair (TAPP)
|
N/A | |
Completed |
NCT01117337 -
Comparing Non-fixation of Mesh to Mesh Fixation in Laparoscopic Inguinal Hernia Repair
|
Phase 4 | |
Terminated |
NCT00226161 -
Chronic Pain After Inguinal Herniorrhaphy
|
N/A | |
Completed |
NCT05837013 -
Open and Laparoscopic Total Extraperitoneal Repair Under Spinal Anesthesia Versus General Anesthesia
|
N/A | |
Recruiting |
NCT05058378 -
Correlation Between Spinal Anesthesia and Perfusion Index
|
||
Completed |
NCT01637818 -
Long-term Follow-up of Lichtenstein's Operation Versus Mesh Plug Repair
|
N/A | |
Recruiting |
NCT05879770 -
Is the Use of Prolene as Sufficient as the Use of Wire in Shouldice Surgery to Keep the Recurrence Rate Low After One Year?
|
||
Completed |
NCT05159232 -
Length of Hospital Stay in Laparoscopic Transabdominal Preperitoneal Vs. Open Mesh Repair in Inguinal Hernia: A Randomised Controlled Trial
|
N/A | |
Completed |
NCT05107986 -
Laparoscopy in Complicated Groin Hernia
|
||
Active, not recruiting |
NCT04328597 -
Portuguese Inguinal Hernia Cohort (PINE) Study
|
||
Completed |
NCT04033055 -
Antalgic Efficacy of CycloMeshâ„¢ Soaked in Ropivacaine Hydrochloride in Uncomplicated Inguinal Hernia.
|
N/A |