Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT00664950
Other study ID # R-08-002
Secondary ID 13619
Status Completed
Phase N/A
First received April 18, 2008
Last updated September 1, 2015
Start date November 2007
Est. completion date December 2014

Study information

Verified date September 2015
Source Lawson Health Research Institute
Contact n/a
Is FDA regulated No
Health authority Canada: Ethics Review Committee
Study type Interventional

Clinical Trial Summary

Elderly patients with an intertrochanteric hip fracture will be randomized to receive either a sliding hip screw (SHS) (control group) or InterTAN intermedullary nail (IMN) (experimental group) for surgical fixation of their hip fracture. This study will assess functional and mortality outcomes for elderly patients with hip fractures.


Description:

Outcome after hip fracture in the elderly is generally poor. According to the World Health Organization, fracture of the hip is associated with 20 % 1-year mortality and 50 % loss of function33. However, the high mortality and loss of function can be improved. For example, numerous studies have shown improvement in relevant outcomes when interventions such as improved thromboprophylaxis, care pathways and timely surgery are achieved. Up to 50 % decreases in mortality can be achieved with these interventions1,2,3.

While improvements in perioperative care can improve outcome, the benefit of newer surgical techniques and implants is less clear. This is well demonstrated in the case of intertrochanteric fractures. Intertrochanteric fractures are those in which the primary fracture line occurs between the greater and lesser trochanter and include approximately 50 % of all hip fractures. Many surgical implants have been developed for this common fracture pattern; in general, the conventional implant is a sliding hip screw (SHS) in which a plate is fixed to the lateral cortex of the femur, distal to the fracture; and a large-diameter screw is placed in the centre of the femoral head, proximal to the fracture. The screw and plate slide relative to one another, permitting compression of the fracture and facilitating bone healing. In contrast, the newer implants are typically intramedullary nail designs (IMN), in which a metal nail is placed within the canal of the femur and a large-diameter screw is placed in the centre of the femoral head. The theoretical advantage of newer designs is based upon, first, an improved stability of the implant, allowing earlier and more aggressive mobilization; and second, a less invasive surgical procedure to minimize blood loss. Nonetheless, repeated trials and meta-analyses have failed to demonstrate an advantage to the IMN designs compared to SHS. In fact, perioperative complications seem to be higher using the IMN designs4,5.

There are two primary reasons why IMN designs have not translated into improved results to date. First, perioperative complications, especially fractures of the femur, are more common with current IMN designs. Second, the supposed improved stability conferred by these devices may not actually be achieved. Current IMN designs retain the original concept of a single screw in the femoral head, which does not prevent rotation of the femoral head - a common reason for implant failure. As well, most current IMN designs permit unrestricted axial shortening of the femur, which may lead to significant leg length changes and alter gait.

A new implant has been designed to take advantage of the inherent theoretical strengths of IMN designs and improve upon current design flaws. The InterTAN device (IT) has been designed to improve stability after fixation of intertrochanteric fractures. This device has a double proximal hip screw, to achieve rotational control; improved implant geometry, to improve immediate stability; and immediate compression to achieve stability while avoiding uncontrolled leg length changes. The IT device retains the percutaneous insertion technique of other IMN devices and simplifies insertion with redesigned instrumentation. The InterTAN device is the first device designed specifically to provide enhanced stability to intertrochanteric fractures and seems to offer significant promise compared to other IM designs.

The InterTAN device has not, as of yet, been compared to conventional surgical techniques. According to the Cochrane Database Reviews, "Any new design should be evaluated in a randomised comparison with the sliding hip screw."


Recruitment information / eligibility

Status Completed
Enrollment 240
Est. completion date December 2014
Est. primary completion date August 2014
Accepts healthy volunteers No
Gender Both
Age group 55 Years and older
Eligibility Inclusion Criteria:

1. Age 55 years or greater*

2. Intertrochanteric fracture amenable to treatment by sliding hip screw or intramedullary nail fixation

3. Previously ambulatory (defined as not usually requiring a wheelchair for ambulation)*

4. Provision of informed consent*

5. Surgery performed within 72 hours of admission

Exclusion Criteria:

1. Cognitive or language barriers that would limit completion of assessment tests in English*

2. Anticipated problems with follow-up in the judgment of the resident, or attending surgeon (e.g of no fixed address)*

3. Surgeon refusal to randomize patient

4. Pathologic fractures

5. Polytrauma that would impact functional assessments in the opinion of the surgeon

Study Design

Allocation: Randomized, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Device:
sliding hip screw
surgical repair of hip fracture using conventional sliding hip screw
IntertAn IM nail
interTAN IM nail

Locations

Country Name City State
Canada London Health Sciences Centre London Ontario
Canada Ottawa Civic Hospital Ottawa Ontario
Canada Saint John Regional Hosptial Saint John New Brunswick

Sponsors (2)

Lead Sponsor Collaborator
Lawson Health Research Institute Orthopaedic Research Foundation

Country where clinical trial is conducted

Canada, 

Outcome

Type Measure Description Time frame Safety issue
Primary Functional Independence Measure (FIM) prospective No
Primary Timed up an go (TUG) prospective No
Secondary 2-minute walk test (2MWT) prospective No
Secondary Geriatric Depression Scale (GDS) prospective No
Secondary Lower Extremity Measure (LEM) prospective No
Secondary Complications prospective No
Secondary Femoral shortening prospective No
Secondary Blood Loss prospective No
Secondary Mortality prospective No
See also
  Status Clinical Trial Phase
Completed NCT02507609 - Deep Neuromuscular Block on Cytokines Release and Postoperative Delirium N/A
Completed NCT03906864 - Care Pathway for Sub-acute Hip Rehabilitation N/A
Recruiting NCT04063891 - Vibration Therapy as an Intervention for Enhancing Trochanteric Hip Fracture Healing in Elderly Patients N/A
Completed NCT05039879 - Life Improving Factors After a Hip Fracture
Not yet recruiting NCT03887494 - Study of the Impact of the Femoral Implant "Y-strut" on Lytic Bone Metastases of the Femoral Neck (WAZA-ARY) N/A
Terminated NCT03065101 - Trigen InterTAN vs Sliding Hip Screw RCT N/A
Completed NCT03545347 - Physiotherapy, Nutritional Supplement and Anabolic Steroids in Rehabilitation of Patients With Hip Fracture. Phase 2
Completed NCT03695081 - Patient Pathway Pharmacist - Optimal Drug-related Care N/A
Recruiting NCT05971173 - Nutritional Optimization and Bone Health Management for Older Adults Undergoing Hip Fracture Surgery Early Phase 1
Active, not recruiting NCT04957251 - Anterior vs Posterior Approach for Hip Hemiarthroplasty N/A
Terminated NCT04372966 - Uncemented Versus Cemented Total Hip Arthroplasty for Displaced Intracapsular Hip Fractures N/A
Withdrawn NCT05030688 - Fascia Iliaca Compartment Block and PENG Block for Hip Arthroplasty N/A
Completed NCT04424186 - 'Rehabilitation for Life' N/A
Not yet recruiting NCT04183075 - Impact of a Nutritional Supplement on the Recovery of the Nutritional Status of Patients With Spontaneous Hip Fracture N/A
Withdrawn NCT05518279 - Early Administration Of Tranexamic Acid And Acute Blood Loss In Patients With Hip Fractures Phase 3
Not yet recruiting NCT02892968 - ED Ultrasonographic Regional Anesthesia to Prevent Incident Delirium in Hip Fracture Patients N/A
Not yet recruiting NCT02223572 - Secondary Fracture Prevention in Patients Who Suffered From Osteoporotic Fracture N/A
Active, not recruiting NCT02247791 - Uncemented Compared to Cemented Femoral Stems in Total Hip Arthroplasty N/A
Completed NCT00746876 - Unipolar or Bipolar Hemiarthroplasty in the Treatment of Displaced Femoral Neck Fractures. N/A
Completed NCT00058864 - The HIP Impact Protection Program (HIP PRO) N/A