Hip Fractures Clinical Trial
Official title:
A Multi-centre Randomized Control Trail Comparing a Novel Intramedullary Device (InterTAN) Versus Conventional Treatment (Sliding Hip Screw) of Geriatric Fractures.
Elderly patients with an intertrochanteric hip fracture will be randomized to receive either a sliding hip screw (SHS) (control group) or InterTAN intermedullary nail (IMN) (experimental group) for surgical fixation of their hip fracture. This study will assess functional and mortality outcomes for elderly patients with hip fractures.
Outcome after hip fracture in the elderly is generally poor. According to the World Health
Organization, fracture of the hip is associated with 20 % 1-year mortality and 50 % loss of
function33. However, the high mortality and loss of function can be improved. For example,
numerous studies have shown improvement in relevant outcomes when interventions such as
improved thromboprophylaxis, care pathways and timely surgery are achieved. Up to 50 %
decreases in mortality can be achieved with these interventions1,2,3.
While improvements in perioperative care can improve outcome, the benefit of newer surgical
techniques and implants is less clear. This is well demonstrated in the case of
intertrochanteric fractures. Intertrochanteric fractures are those in which the primary
fracture line occurs between the greater and lesser trochanter and include approximately 50
% of all hip fractures. Many surgical implants have been developed for this common fracture
pattern; in general, the conventional implant is a sliding hip screw (SHS) in which a plate
is fixed to the lateral cortex of the femur, distal to the fracture; and a large-diameter
screw is placed in the centre of the femoral head, proximal to the fracture. The screw and
plate slide relative to one another, permitting compression of the fracture and facilitating
bone healing. In contrast, the newer implants are typically intramedullary nail designs
(IMN), in which a metal nail is placed within the canal of the femur and a large-diameter
screw is placed in the centre of the femoral head. The theoretical advantage of newer
designs is based upon, first, an improved stability of the implant, allowing earlier and
more aggressive mobilization; and second, a less invasive surgical procedure to minimize
blood loss. Nonetheless, repeated trials and meta-analyses have failed to demonstrate an
advantage to the IMN designs compared to SHS. In fact, perioperative complications seem to
be higher using the IMN designs4,5.
There are two primary reasons why IMN designs have not translated into improved results to
date. First, perioperative complications, especially fractures of the femur, are more common
with current IMN designs. Second, the supposed improved stability conferred by these devices
may not actually be achieved. Current IMN designs retain the original concept of a single
screw in the femoral head, which does not prevent rotation of the femoral head - a common
reason for implant failure. As well, most current IMN designs permit unrestricted axial
shortening of the femur, which may lead to significant leg length changes and alter gait.
A new implant has been designed to take advantage of the inherent theoretical strengths of
IMN designs and improve upon current design flaws. The InterTAN device (IT) has been
designed to improve stability after fixation of intertrochanteric fractures. This device has
a double proximal hip screw, to achieve rotational control; improved implant geometry, to
improve immediate stability; and immediate compression to achieve stability while avoiding
uncontrolled leg length changes. The IT device retains the percutaneous insertion technique
of other IMN devices and simplifies insertion with redesigned instrumentation. The InterTAN
device is the first device designed specifically to provide enhanced stability to
intertrochanteric fractures and seems to offer significant promise compared to other IM
designs.
The InterTAN device has not, as of yet, been compared to conventional surgical techniques.
According to the Cochrane Database Reviews, "Any new design should be evaluated in a
randomised comparison with the sliding hip screw."
;
Allocation: Randomized, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02507609 -
Deep Neuromuscular Block on Cytokines Release and Postoperative Delirium
|
N/A | |
Completed |
NCT03906864 -
Care Pathway for Sub-acute Hip Rehabilitation
|
N/A | |
Recruiting |
NCT04063891 -
Vibration Therapy as an Intervention for Enhancing Trochanteric Hip Fracture Healing in Elderly Patients
|
N/A | |
Completed |
NCT05039879 -
Life Improving Factors After a Hip Fracture
|
||
Not yet recruiting |
NCT03887494 -
Study of the Impact of the Femoral Implant "Y-strut" on Lytic Bone Metastases of the Femoral Neck (WAZA-ARY)
|
N/A | |
Terminated |
NCT03065101 -
Trigen InterTAN vs Sliding Hip Screw RCT
|
N/A | |
Completed |
NCT03695081 -
Patient Pathway Pharmacist - Optimal Drug-related Care
|
N/A | |
Completed |
NCT03545347 -
Physiotherapy, Nutritional Supplement and Anabolic Steroids in Rehabilitation of Patients With Hip Fracture.
|
Phase 2 | |
Recruiting |
NCT05971173 -
Nutritional Optimization and Bone Health Management for Older Adults Undergoing Hip Fracture Surgery
|
Early Phase 1 | |
Active, not recruiting |
NCT04957251 -
Anterior vs Posterior Approach for Hip Hemiarthroplasty
|
N/A | |
Terminated |
NCT04372966 -
Uncemented Versus Cemented Total Hip Arthroplasty for Displaced Intracapsular Hip Fractures
|
N/A | |
Withdrawn |
NCT05030688 -
Fascia Iliaca Compartment Block and PENG Block for Hip Arthroplasty
|
N/A | |
Completed |
NCT04424186 -
'Rehabilitation for Life'
|
N/A | |
Not yet recruiting |
NCT04183075 -
Impact of a Nutritional Supplement on the Recovery of the Nutritional Status of Patients With Spontaneous Hip Fracture
|
N/A | |
Withdrawn |
NCT05518279 -
Early Administration Of Tranexamic Acid And Acute Blood Loss In Patients With Hip Fractures
|
Phase 3 | |
Not yet recruiting |
NCT02892968 -
ED Ultrasonographic Regional Anesthesia to Prevent Incident Delirium in Hip Fracture Patients
|
N/A | |
Not yet recruiting |
NCT02223572 -
Secondary Fracture Prevention in Patients Who Suffered From Osteoporotic Fracture
|
N/A | |
Active, not recruiting |
NCT02247791 -
Uncemented Compared to Cemented Femoral Stems in Total Hip Arthroplasty
|
N/A | |
Completed |
NCT00746876 -
Unipolar or Bipolar Hemiarthroplasty in the Treatment of Displaced Femoral Neck Fractures.
|
N/A | |
Completed |
NCT00058864 -
The HIP Impact Protection Program (HIP PRO)
|
N/A |