Clinical Trials Logo

Clinical Trial Summary

This is a prospective study to determine the optimal technique for obtaining liver tissue with a smaller caliber (22 gauge) needle and whether a good core biopsy can be obtained without the use of suction and secondly to determine the diagnostic yield and safety of 22 g Fine Needle Biopsy needle for liver biopsy.


Clinical Trial Description

Liver biopsy (LB) has historically been performed by percutaneous route without image guidance (blind biopsy). However, in the last several years there has been more reliance on image guidance ultrasound-guided (USG) or computed tomography (CT) to direct the needle into the liver with the hope of limiting complications. Other ways of performing liver biopsy are transjugular fluoroscopy guided approach when percutaneous route is deemed not safe because of coagulopathy or ascites. Surgical LB (either laparoscopic or open) is yet another way of obtaining liver tissue.

Endoscopic ultrasound guided liver biopsy (EUS-LB) is proposed as a newer method that may offer several potential advantages over existing techniques for attaining liver tissue. It can be performed in an outpatient setting and offers the comfort of sedation and analgesia. Endoscopic Ultrasound (EUS) provides high resolution images of left lobe of the liver and a good portion of the right lobe of the liver. This coupled with Doppler capability the biopsy needle can be safely directed into the liver for sampling under real time image guidance. Intervening structures such as pleura, bowel loops and gallbladder can be easily seen by EUS and thus avoided that further decreases the risk of adverse events. It has been recognized that sampling error can lead to diagnostic inaccuracy of a biopsy from a single site. As compared to USG or CT scan the EUS allows easy and safe biopsy of both left and right lobes of the liver during same setting, potentially addressing concerns about sampling error.

The cost of the endoscopic procedure is the main expense of EUS-LB. Thus this approach is best used for patients requiring EUS for evaluation of elevated liver tests. If no obstructive lesion is identified by EUS that will require endoscopic retrograde cholangiopancreatography (ERCP) then it would cost-effective to perform EUS-LB during the same setting without much additional time and risks. This approach can spare the patient the additional discomfort and expense of a second dedicated LB procedure by any of the other available techniques (percutaneous, transjugular etc.). In such setting the equipment costs for the EUS-LB will mainly include only the Fine Needle Biopsy (FNB) needle, which is similar in expense to the cost of needles for the transjugular or percutaneous approach.

The traditionally used transcutaneous LB needle is 16 gauge (G) while largest EUS biopsy needle is 19 G. The smaller size of the needle is expected to decrease the complications rate (mainly pain and bleeding) even further. Many studies using a 19 G Tru-cut biopsy or Fine Needle Aspiration (FNA) needle to acquire liver tissue have obtained specimens adequate for histologic diagnosis but there has been a wide range of specimen adequacy (19-100%). The 19 G Tru-cut biopsy needle has been associated with several technical difficulties that could reflect negatively on tissue adequacy.

While it is easy and straight forward to biopsy the left lobe of the liver with any EUS needle. The 19 G needle is a large bore needle for EUS use and it is sometimes difficult to attain an adequate position for biopsy specially in duodenum where scope is torqued and this is the only area of access to right lobe.

In this study the investigators will use a 22 G needle. Smaller caliber of the needle would not only make it technically easier to access right lobe of the liver through the duodenum, it is also expected to decrease the risks further due to smaller size. Also, the 22 G EUS-FNB needle has three cutting points at the cutting edge of the needle that provide stability at puncture while the high quality, fully formed heels are designed to maximize tissue capture and minimize fragmentation, that would result in attaining a good histological specimen, a main stay for liver biopsy. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03307811
Study type Interventional
Source Florida Hospital
Contact
Status Completed
Phase N/A
Start date August 1, 2017
Completion date October 1, 2018

See also
  Status Clinical Trial Phase
Recruiting NCT03253250 - The Investigation of Peginterferon Alfa-2a on the RFS of the Subjects With HCC Who Have Been Treated by Resection Phase 4
Terminated NCT01760616 - Huaier Granule for Prevention of Disease Progression of Hepatocarcinoma After Non-radical Hepatectomy Phase 4
Active, not recruiting NCT04682847 - Radiotherapy With Iron Oxide Nanoparticles (SPION) on MR-Linac for Primary & Metastatic Hepatic Cancers
Not yet recruiting NCT03149523 - Exhaustive Genetic and Immunological Characterization of Colon, Kidney and Liver Tumors N/A
Recruiting NCT05009550 - ESP Block on Patient Outcomes in Patients With Liver Tumor Undergoing Radiofrequency Ablation N/A
Recruiting NCT06342414 - An Exosome-Based Liquid Biopsy for the Differential Diagnosis of Primary Liver Cancer
Recruiting NCT03132740 - Impact of Three-dimensional Visualization on Operation Strategy and Complications for Complex Hepatic Carcinoma
Completed NCT03164382 - Hepatic Arterial Infusion of Oxaliplatin, Fluorouracil/Leucovorin Versus Sorafenib in Advanced Hepatocellular Carcinoma Phase 3
Completed NCT03572582 - Transarterial Chemoembolization in Combination With Nivolumab Performed for Intermediate Stage Hepatocellular Carcinoma Phase 2
Completed NCT04266548 - Arterial Base Fluorescence Segmental Positive Staining N/A
Recruiting NCT03013712 - A Clinical Research of CAR T Cells Targeting EpCAM Positive Cancer Phase 1/Phase 2
Recruiting NCT01350726 - Functional-three-dimensional Reconstruction of Liver by 99MTc-GSA-SPECT Scan N/A
Completed NCT06245798 - Liver Resection for Patients With Hepatocellular Carcinoma and Clinically Significant Portal Hypertension
Recruiting NCT06311396 - Development of a Neuronal Microscope N/A
Recruiting NCT04220944 - Combined Locoregional Treatment With Immunotherapy for Unresectable HCC. Phase 1
Completed NCT02352935 - Percutaneous Irreversible Electroporation for Unresectable Hepatic Carcinoma in Poor Liver Function N/A
Completed NCT02332551 - Percutaneous Irreversible Electroporation to Treat Liver Cancer Close to the Gallbladder N/A
Completed NCT02834780 - Phase 1 Study to Evaluate the Safety, Pharmacokinetics and Pharmacodynamics of H3B-6527 in Participants With Advanced Hepatocellular Carcinoma Phase 1
Not yet recruiting NCT06182865 - A Study of Ga-68 Dolacga to Evaluate Liver Reserve Function in Patients With HCC Before and After Proton Therapy N/A
Completed NCT05007548 - to Assess the Accuracy and Reliability of the Ga68-Dolacga Positron Emission Tomography Compared to Computer Tomography Volumetry and Indocyanine Green Retention Test for Measurement of Liver Reserve Phase 2