Clinical Trials Logo

Clinical Trial Summary

During hemodialysis (HD) the blood of the patient pass an extracorporeal circuit that contains a dialyzer for rinsing and a venous chamber (air trap) to prevent from air embolism through the return blood into the patient. However, air traps in clinical use have limited capacity to prevent from microemboli of air to enter the return bloodline and deposit as emboli in the body such as lungs, heart and brain. The Investigator developed the air trap Emboless that was patented. In vitro studies showed significantly better reduction of microemboli contaminations than air traps compared to that in clinical use. The present randomized clinical trial compares two different air traps used by the same patients in a cross-over design (as pairs) using the Emboless compared with the Fresenius 4008/5008 (F5008). Chronic HD patients are randomized to perform the first HD with either their standard air trap (F5008) in the venous bloodline tubing or using the Emboless bloodline and vice versa. Each patient was included to make two paired series. A safety committee evaluates if significantly worse outcome appears especially with the Emboless, to stop the study. During HD the microbubbles are counted by a GAMPT ultrasound device using two probes. One probe is set at the inlet side of the air trap and the second at the outlet side. The outlet side represents data of microbubbles in the blood that are entering into the patient. Comparative non-parametric paired analyses are performed between the air traps. Monitoring of the study is performed.


Clinical Trial Description

During hemodialysis (HD) the blood of the patient pass an extracorporeal circuit that contains a dialyzer for rinsing and a venous chamber (air trap) to prevent from air embolism through the return blood into the patient. However, air traps in clinical use have limited capacity to prevent from microemboli of air to enter the return bloodline and deposit as emboli in the body such as lungs, heart and brain. The Investigator developed the air trap Emboless that was patented in Europe, USA and India. In vitro studies showed significantly better reduction of microemboli contaminations than air traps compared to that in clinical use. The present randomized clinical trial compares two different air traps used by the same patients in a cross-over design (as pairs) using the Emboless compared with the Fresenius 4008/5008 (F5008). Chronic HD patients are randomized to perform the first HD with either their standard air trap (F5008) in the venous bloodline tubing or using the Emboless bloodline and vice versa. Each patient is included to make two paired series. A maximum of 30 patients are planned. Each with 2 series of each two different sets of air traps that would give a total of 120 dialyses. A safety committee evaluates if significantly worse outcome appears especially with the Emboless. During HD the microbubbles are counted by a GAMPT ultrasound device using two probes. One probe is set at the inlet side of the air trap and the second at the outlet side. The outlet side represents data of microbubbles in the blood that are entering into the patient. Comparative non-parametric paired analyses are performed between the air traps. Monitoring of the study is performed. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06168539
Study type Interventional
Source Umeå University
Contact Ulf Forsberg, MD, PhD
Phone +46907850000
Email ulf.forsberg@regionvasterbotten.se
Status Recruiting
Phase N/A
Start date May 11, 2022
Completion date March 15, 2024

See also
  Status Clinical Trial Phase
Completed NCT05980845 - The Effect Nature Sounds and Music on Hemodialysis Patients N/A
Recruiting NCT05020717 - Retrospective Survey of Hyperkalemia in Hemodialysis
Recruiting NCT04046042 - Virtual Reality Intradialysis: Last vs. First Part of the Session N/A
Recruiting NCT04094038 - The Effect of Intradialytic Parenteral Nutrition on Nutritional Status and Quality of Life in Hemodialysis Patients Phase 4
Completed NCT03311581 - The Feasibility of Propofol TCI in Hemodialysis Patients Undergoing Arteriovenous Shunt Surgery Phase 1
Completed NCT05531175 - REIKI APPLICATION PAIN, FATIGUE AND ITCHING IN HEMODIALYSIS PATIENTS N/A
Completed NCT03061552 - Inferior Vena Cava Sonography in Hemodialysis Patients and Quality of Life N/A
Completed NCT04057313 - Coffee in Hemodialysis and Headache N/A
Completed NCT03251573 - The Cohort Study of Cognitive Impairment in Chinese Hemodialysis Patients
Completed NCT05568342 - The Effect of Roy Adaptation-Based Nursing Intervention N/A
Completed NCT03527680 - Effect of Lactobacillus Rhamnosus on Serum Uremic Toxins in Hemodialysis N/A
Completed NCT04063423 - Non- Clinical Coagulation Activation During Hemodialysis
Active, not recruiting NCT06203795 - Dialysis Performance of the FX CorAL Membrane N/A
Recruiting NCT04319328 - Is Cefazolin, Ceftazidime and Ciprofloxacin Dosing Optimal in Hemodialysis Patients?
Completed NCT03627884 - Outcomes of the Use of Sodium Bicarbonate (8.4%) Solution as a Catheter Lock Solution to Prevent Hemodialysis Catheter Loss Due to Lumen Clot Formation Phase 4
Completed NCT05132036 - Lung Ultrasound Assessment of Fluid Overload in Haemodialysis Patients N/A
Completed NCT03076528 - An Innovative Virtually Supervised Exercise for Dialysis Patients Phase 2
Recruiting NCT06098443 - Acupressure Versus Transcutaneous Electrical Nerve Stimulation on Pain and Quality of Life Intradialysis N/A
Not yet recruiting NCT05534542 - Comparıson of the effectıveness of ıntradıalıtıc Core stabılızatıon and aerobıc exercıse ın hemodıalysıs patıents N/A
Completed NCT04645121 - Carbon Monoxide-based Rebreathing Method and Bioimpedance in Hemodialysis Patients