Heart Failure Clinical Trial
Official title:
Method and Sample Comparison Study of Minicare BNP at a Central Laboratory
| Verified date | September 2017 |
| Source | Philips Handheld Diagnostics |
| Contact | n/a |
| Is FDA regulated | No |
| Health authority | |
| Study type | Observational |
Sample Comparison The objective of this study is to compare the Philips Minicare BNP test
with the Centaur BNP test. BNP level measured in human blood samples (EDTA venous whole blood
and/or EDTA plasma) will be assessed. Matrix Comparison To compare BNP measurements obtained
using Minicare System for EDTA whole blood and EDTA plasma samples.Prior to the study start,
a proficiency study will be performed on the Minicare BNP, Architect and I-STAT BNP assay to
be sure that devices are performing according to expectations. Approximately 100 EDTA patient
whole blood samples covering the entire measuring range of Minicare BNP from LOQ until end of
measuring range (expected to be approximately 5000 ng/L) (Ref 7) will be tested (according to
CLSI EP09A3 (Ref 5)) at a central laboratory using the Minicare BNP, Alere BNP, I-STAT BNP
system. The outcome of the site routine assay (Centaur BNP systems) will be used to evaluate
if the blood samples cover the entire distribution range of the assay. If necessary, up to
20% of the samples may be spiked so that the entire range of the assay is covered. The
central laboratory will identify the blood tubes with a BNP request. Approximately 1000 μl
EDTA whole blood will be available (left over material) for testing on the non-routine
devices (i.e., Minicare BNP, Alere BNP, and I-STAT BNP). Testing for the Alere BNP, I-STAT
BNP, and Centaur BNP systems will be performed according to the respective IFU's (Ref 1, 2,
3, 4). For the Minicare BNP system, test will be performed according to a DRAFT IFU or a
similar document describing the sample treatment and handling for the Minicare BNP system.
Alere BNP, I-STAT BNP and Minicare BNP samples should be tested within 6 hours after
collection and Centaur BNP samples within 8h of collection. Although different stability
claims for BNP, it is highly recommended to perform all measurements on all systems within 2
hours. For Alere BNP, I-STAT BNP, Centaur BNP analysis will be performed using a single blood
sample for each patient. Alere BNP and I-STAT will use EDTA whole blood samples as sample
type Centaur BNP will be tested on EDTA plasma samples. For the Minicare BNP, both EDTA whole
blood and EDTA plasma will be tested for each patient. For the Minicare BNP system the whole
blood samples will be tested using a pipette and the same sample will be tested using the
SmearSafe Blood Dispenser (transfer device) to investigate a reliable use of such transfer
device.
Only the routine Centaur BNP outcomes will be used as part of support for patient diagnosis.
| Status | Completed |
| Enrollment | 296 |
| Est. completion date | April 14, 2017 |
| Est. primary completion date | April 14, 2017 |
| Accepts healthy volunteers | No |
| Gender | All |
| Age group | 18 Years and older |
| Eligibility | Left over blood samples from eligible patients with BNP requests, available at the test site CENTRAL LABORATORY will be selected for this study. |
| Country | Name | City | State |
|---|---|---|---|
| Netherlands | Diagnostiek voor U | Eindhoven |
| Lead Sponsor | Collaborator |
|---|---|
| Philips Handheld Diagnostics |
Netherlands,
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | To investigate the bias between the Philips Minicare BNP test with the Centaur BNP test of the measurement procedures.BNP level measured in human blood samples (EDTA venous whole blood and/or EDTA plasma) will be assessed. | To investigate the bias between the Philips Minicare BNP test with the Centaur BNP test using values spanning the common measuring interval of the measurement procedures.BNP level measured in human blood samples (EDTA venous whole blood and/or EDTA plasma) will be assessed. | May 2017 | |
| Primary | To compare BNP measurements obtained using Minicare System for EDTA whole blood and EDTA plasma samples. | To compare BNP measurements obtained using Minicare System for EDTA whole blood and EDTA plasma samples. | May 2017 | |
| Secondary | Percentage of agreement systems | To estimate the percent of agreement between the Minicare System and three commercially available BNP systems (i.e., Alere BNP, I-STAT BNP, and Centaur BNP tests) using a cut-off value of 100ng/L. | May 2017 | |
| Secondary | Percentage of agreement samples | To estimate the percent of agreement between EDTA whole blood and EDTA plasma samples for Minicare system using a BNP cut off value of 100ng/L | May 2017 | |
| Secondary | Evaluate performance of the SmearSafe Blood Dispenser (transfer device), for transferring whole blood from the blood tube directly to the Minicare BNP cartridge. | Evaluate performance of the SmearSafe Blood Dispenser (transfer device), for transferring whole blood from the blood tube directly to the Minicare BNP cartridge, so without use of pipette. | May 2017 |
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT05650307 -
CV Imaging of Metabolic Interventions
|
||
| Recruiting |
NCT05196659 -
Collaborative Quality Improvement (C-QIP) Study
|
N/A | |
| Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
| Active, not recruiting |
NCT05896904 -
Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction
|
N/A | |
| Completed |
NCT05077293 -
Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
|
||
| Recruiting |
NCT05631275 -
The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
|
||
| Enrolling by invitation |
NCT05564572 -
Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology
|
N/A | |
| Enrolling by invitation |
NCT05009706 -
Self-care in Older Frail Persons With Heart Failure Intervention
|
N/A | |
| Recruiting |
NCT04177199 -
What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
|
||
| Terminated |
NCT03615469 -
Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY)
|
N/A | |
| Recruiting |
NCT06340048 -
Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure
|
Phase 1/Phase 2 | |
| Recruiting |
NCT05679713 -
Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
|
||
| Completed |
NCT04254328 -
The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure
|
N/A | |
| Completed |
NCT03549169 -
Decision Making for the Management the Symptoms in Adults of Heart Failure
|
N/A | |
| Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
| Enrolling by invitation |
NCT05538611 -
Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
|
||
| Recruiting |
NCT04262830 -
Cancer Therapy Effects on the Heart
|
||
| Completed |
NCT06026683 -
Conduction System Stimulation to Avoid Left Ventricle Dysfunction
|
N/A | |
| Withdrawn |
NCT03091998 -
Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support
|
Phase 1 | |
| Recruiting |
NCT05564689 -
Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy
|