Heart Failure Clinical Trial
Official title:
Electromagnetic Interference by Transcutaneous Neuromuscular Electrical Stimulation in Patients With Optimizer(R) - a Pilot Safety Study
Systemic skeletal muscle atrophy (cachexia) is a typical side effect of chronic heart
failure.
Patients with cachexia can benefit from transcutaneous electrical neuromuscular stimulation
(TENS). It is applied to strengthen the musculature and improve exercise tolerance and
quality of life.
It is unclear if application of TENS can cause electromagnetic interference (EMI) in
patients with Optimizer® pacemaker systems for improvement of heart failure.
This pilot safety study enrolled 6 patients with chronic heart failure and reduced left
ventricular ejection fraction. All patients had an Optimizer® pacemaker system implanted for
a minimum of 6 months, no patients had any ventricular arrhythmic episode 3 months prior to
the study, and all were in clinically stable condition and willing to participate in this
study.
Neuromuscular stimulation was administered via TENS in 4 different modes (HF, LF, Burst, MF)
on the right and left musculus trapezius and on both musculi quadriceps femoris. All
patients were tested for EMI without or with cardiac contractility modulation (CCM) delivery
of the Optimizer®-system respectively.
| Status | Completed |
| Enrollment | 6 |
| Est. completion date | October 2015 |
| Est. primary completion date | August 2015 |
| Accepts healthy volunteers | No |
| Gender | Male |
| Age group | 18 Years to 99 Years |
| Eligibility |
Inclusion Criteria: - >18 years, with implantation of the Optimizer ® >6 months ago, clinically stable condition and without any ventricular arrhythmic episode in the last 3 months. Exclusion Criteria: - Local swelling or edema at the site of stimulation, intolerance to electrical stimulation, or presence of other metallic implants at the site of stimulation |
Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Basic Science
| Country | Name | City | State |
|---|---|---|---|
| n/a | |||
| Lead Sponsor | Collaborator |
|---|---|
| Medical University of Vienna |
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | The patients with CCM-system are assessed for EMI during TENS-application | Electromagnetic interference can cause artificial sensing in pacemaker or ICD system. These artefacts may have the effect of suppressing the pacemaker pulses sensing of tachycardia in ICD. The patients will be exposed to electrical stimulations, which will be of different forces on the neck and the upper thigh with r4x. These impulses and the effects will be noted down. It will be investigated if there is an interference with the optimizer ® depending on the different sites of the electrical stimulations and the different impulse forces. Many patients with an Optimizer ® have simultaneously a pacemaker - or ICD implant. A special extra monitor will note if there are probable interferences with these pacemaker- or ICD implants. |
6 months | No |
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
| Recruiting |
NCT05650307 -
CV Imaging of Metabolic Interventions
|
||
| Recruiting |
NCT05196659 -
Collaborative Quality Improvement (C-QIP) Study
|
N/A | |
| Active, not recruiting |
NCT05896904 -
Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction
|
N/A | |
| Completed |
NCT05077293 -
Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
|
||
| Recruiting |
NCT05631275 -
The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
|
||
| Enrolling by invitation |
NCT05564572 -
Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology
|
N/A | |
| Enrolling by invitation |
NCT05009706 -
Self-care in Older Frail Persons With Heart Failure Intervention
|
N/A | |
| Recruiting |
NCT04177199 -
What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
|
||
| Terminated |
NCT03615469 -
Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY)
|
N/A | |
| Recruiting |
NCT06340048 -
Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure
|
Phase 1/Phase 2 | |
| Recruiting |
NCT05679713 -
Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
|
||
| Completed |
NCT04254328 -
The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure
|
N/A | |
| Completed |
NCT03549169 -
Decision Making for the Management the Symptoms in Adults of Heart Failure
|
N/A | |
| Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
| Enrolling by invitation |
NCT05538611 -
Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
|
||
| Recruiting |
NCT04262830 -
Cancer Therapy Effects on the Heart
|
||
| Completed |
NCT06026683 -
Conduction System Stimulation to Avoid Left Ventricle Dysfunction
|
N/A | |
| Withdrawn |
NCT03091998 -
Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support
|
Phase 1 | |
| Recruiting |
NCT05564689 -
Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy
|