Heart Failure Clinical Trial
Official title:
Influence of Edoxaban on Coagulability and Thrombin Generation: An in Vitro Study Focusing on Thrombelastography
The influence of different doses of edoxaban on physical characteristics of the clot and
thrombin generation kinetics in blood samples will be studied by in vitro spiking of blood
samples collected from patients treated for heart failure (with and without
hypercoagulability) and from healthy volunteers (with and without hypercoagulability). This
in vitro experiment will help us to:
(i) detect qualitative anticlotting properties of edoxaban. (ii) quantify the anticlotting
properties of edoxaban.
Experimental protocol
1. On the day of experiment blood samples will be collected in 3.2% citrate tubes.
2. One citrated blood tube will be centrifuged to collect plasma for biomarker
measurements (C-reactive protein (CRP), fibrinogen, von Willebrand factor (vWF),
interleukin (IL)-6, p-selectin, plasminogen activator inhibitor (PAI)-1, matrix
metalloproteinase (MMP)-9).
3. Blood samples will be incubated with different concentrations of edoxaban (no edoxaban,
subtherapeutic range - 30 nM, therapeutic range -300 nM, and supratherapeutic range-
900 nM) (3).
A) Cora® Hemostasis Analyzer System (Cora®) will be used to assess qualitative and
quantitative assessment of the hemostatic properties of a blood sample in the presence or
absence of edoxaban. The CORA is an integrated computer module with Ethernet connection
capability and provides continuous resonance-frequency viscoelasticity measurements using a
disposable four-channel microfluidic cartridge to determine simultaneous maximal
platelet-fibrin clot strength, fibrin clot strength, and response to antiplatelet agents or
anticoagulants. The cartridge has four channels - citrated Kaolin (CK) channel that measures
platelet-fibrin clot strength, anti-Xa channel, DTI channel and FFC channel that measures
contribution of functional fibrinogen.
In addition, using the V-curve software, the following parameters of thrombin generation
kinetics will be evaluated from the CK channel- R - Period of time of latency from the time
that the blood was placed in the TEG® analyzer until the initial fibrin formation. This
represents the enzymatic portion of coagulation.
K - K time is a measure of the speed to reach a certain level of clot strength. This
represents clot kinetics.
alpha - measures the rapidity of fibrin build-up and cross-linking (clot strengthening).
This represents fibrinogen level.
MA - Maximum Amplitude is a direct function of the maximum dynamic properties of fibrin and
platelet bonding via GPIIb/IIIa and represents the ultimate strength of the fibrin clot.
This represents platelet function/aggregation.
TMRTG - Time to maximum rate of thrombus generation. MRTG - Maximum rate of thrombus
generation. TG - Total thrombus generated. TMRL - Time to maximum rate of lysis MRL -
Maximum rate of lysis L - Total lysis D - Delta is the difference between R time and the
time of initial split point (SP, mins) of the TEG tracing (R - SP), representing the time
interval of greatest clot growth secondary to peak thrombin generation.
B) Calibrated Automated Thrombogram® (CAT) System: Lag time, peak thrombin production, mean
velocity rate index and endogenous thrombin potential (ETP) will be assessed by calibrated
automated thrombogram in platelet poor plasma (Thrombinoscope by Stago).
;
Observational Model: Cohort, Time Perspective: Prospective
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
| Recruiting |
NCT05650307 -
CV Imaging of Metabolic Interventions
|
||
| Recruiting |
NCT05196659 -
Collaborative Quality Improvement (C-QIP) Study
|
N/A | |
| Active, not recruiting |
NCT05896904 -
Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction
|
N/A | |
| Completed |
NCT05077293 -
Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
|
||
| Recruiting |
NCT05631275 -
The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
|
||
| Enrolling by invitation |
NCT05564572 -
Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology
|
N/A | |
| Enrolling by invitation |
NCT05009706 -
Self-care in Older Frail Persons With Heart Failure Intervention
|
N/A | |
| Recruiting |
NCT04177199 -
What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
|
||
| Terminated |
NCT03615469 -
Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY)
|
N/A | |
| Recruiting |
NCT06340048 -
Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure
|
Phase 1/Phase 2 | |
| Recruiting |
NCT05679713 -
Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
|
||
| Completed |
NCT04254328 -
The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure
|
N/A | |
| Completed |
NCT03549169 -
Decision Making for the Management the Symptoms in Adults of Heart Failure
|
N/A | |
| Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
| Enrolling by invitation |
NCT05538611 -
Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
|
||
| Recruiting |
NCT04262830 -
Cancer Therapy Effects on the Heart
|
||
| Completed |
NCT06026683 -
Conduction System Stimulation to Avoid Left Ventricle Dysfunction
|
N/A | |
| Withdrawn |
NCT03091998 -
Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support
|
Phase 1 | |
| Recruiting |
NCT05564689 -
Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy
|